Fluorescent Nanoprobes with Oriented Modified Antibodies to Improve Lateral Flow Immunoassay of Cardiac Troponin I

被引:115
作者
Lou, Doudou [1 ,2 ]
Fan, Lin [1 ,2 ]
Cui, Yan [3 ]
Zhu, Yefei [4 ]
Gu, Ning [1 ,2 ]
Zhang, Yu [1 ,2 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, State Key Lab Bioelect, Jiangsu Key Lab Biomat & Devices, Nanjing, Jiangsu, Peoples R China
[2] Southeast Univ, Collaborat Innovat Ctr Suzhou Nano Sci & Technol, Nanjing, Jiangsu, Peoples R China
[3] Nanjing Nanoeast Biotech Co Ltd, Nanjing, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Affiliated Hosp 2, Lab Med Ctr, Nanjing, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
PROTEIN-G; FC FRAGMENT; IMMOBILIZATION; SENSITIVITY; NANOPARTICLES; MOLECULE;
D O I
10.1021/acs.analchem.7b05410
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Performance of nanoprobes can often determine the detection level of Lateral immunochromatography. Traditional probes were limited by the quantity and orientation of antibodies, immune activity of the Fab region or binding strength between protein and substrate. This study developed a new efficient and robust technology to construct fluorescent nanoprobes with oriented modified antibodies, based on specific binding of the Fc region of antibody with streptococcal protein G (SPG) on the surface of polystyrene microspheres (MS) and subsequent covalent cross-linking at binding sites to firm them. Lateral flow immunoassay using these probes was applied for the detection of cardiac troponin I (cTnI). The significantly improved detection sensitivity demonstrated that antibody orientation on MS surfaces effectively enhanced immunological activities of probes compared with random immobilizing methods. Furthermore, performance evaluation results of lateral flow test strips met clinical requirements perfectly, including limit of detection (0.032 ng/mL), linearity (R > 0.99), repeatability (CV < 10%), correlation (R > 0.99), and heat aging stability. This research also employed heterophilic blocking reagent (HBR) to actively block redundant binding sites of SPG for the first time in order to eliminate false positive interferences, improving the sensitivity and precision of test results further.
引用
收藏
页码:6502 / 6508
页数:7
相关论文
共 32 条
[1]  
AKERSTROM B, 1986, J BIOL CHEM, V261, P240
[2]  
ANDERSON G, 1991, CLIN CHEM, V37, P398
[3]  
[Anonymous], 2016, CAN J NEUROL SCI
[4]   Application of oriented and random antibody immobilization methods in immunosensor design [J].
Baniukevic, Julija ;
Kirlyte, Justina ;
Ramanavicius, Arunas ;
Ramanaviciene, Almira .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 189 :217-223
[5]   Oriented immobilized anti-hIgG via Fc fragment-imprinted PHEMA cryogel for IgG purification [J].
Bereli, Nilay ;
Erturk, Gizem ;
Tumer, M. Askin ;
Say, Ridvan ;
Denizli, Adil .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (05) :599-607
[6]  
BJORCK L, 1984, J IMMUNOL, V133, P969
[7]   Development and characterization of methacrylate-based hydrazide monoliths for oriented immobilization of antibodies [J].
Brne, R. ;
Lim, Y. -P ;
Podgornik, A. ;
Barut, M. ;
Pihlar, B. ;
Strancar, A. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (13) :2658-2663
[8]   Antibody orientation enhanced by selective polymer-protein noncovalent interactions [J].
Clarizia, Lisa-Jo A. ;
Sok, Davin ;
Wei, Ming ;
Mead, Joey ;
Barry, Carol ;
McDonald, Melisenda J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) :1531-1538
[9]  
Del M. G. M., 2009, CURR MICROBIOL, V59, P81
[10]   Langmuir films of Fc binding receptors engineered from protein A and protein G as a sublayer for immunoglobulin orientation [J].
Dubrovsky, T ;
Tronin, A ;
Dubrovskaya, S ;
Guryev, O ;
Nicolini, C .
THIN SOLID FILMS, 1996, 284 :698-702