Two-phase supply of three-phase transformers. Part 2: Wound core type transformers

被引:0
|
作者
Raitsios, P [1 ]
机构
[1] Publ Power Corp Greece, Athens 15234, Greece
来源
关键词
D O I
10.1049/ip-epa:20040539
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The three-phase supply of distribution transformers sometimes changes unexpectedly to two-phase supply, due to external reasons, e.g. a burned fuse or interruption of one of the phases. In this case secondary voltages result which are no longer equal to the nominal phase voltage in all phases, i.e. the one voltage is still equal to the nominal, while the two others are not, but their vector sum is equal to the nominal voltage, since it is obtained from the same primary polar voltage. This occurs for all connections except the star-star connection, for which none of the secondary voltages is equal to the nominal phase voltage. The magnitude of each voltage depends on the ampere-turns, the core dimensions and the magnetic permeability that appears in each core branch (limb). These voltages are calculated from the equivalent magnetic circuit and the magnetising curve of the core material.
引用
收藏
页码:607 / 612
页数:6
相关论文
共 50 条
  • [31] Evaluation of Core Losses in Transformers for Three-phase Multi-level DAB Converters
    Khanzadeh, Babak
    Serdyuk, Yuriy
    Thiringer, Torbjorn
    2022 24TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'22 ECCE EUROPE), 2022,
  • [32] MAGNETIC CIRCUIT ANALYSIS OF WOUND-CORE-TYPE 3-PHASE TRANSFORMERS
    YAMAGUCHI, S
    ELECTRICAL ENGINEERING IN JAPAN, 1966, 86 (05) : 54 - +
  • [33] Comparison of four methods for computing positive-sequence reactances of three-phase core-type transformers
    Sorrentino, Elmer
    Alvarado, Sofia
    Silva, Pedro
    Carlos Burgos, Juan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (07) : 1221 - 1227
  • [34] Analysis of three-phase induction machine operation under two-phase supply
    Schreier, L
    Chomát, M
    Klíma, J
    IEEE ICIT' 02: 2002 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 107 - 112
  • [35] Magnetization of Three-Leg Cores of Three-Phase Transformers Taking into Account the Supply Asymmetry.
    Rachwalski, Janusz
    Przeglad Elektrotechniczny, 1973, 49 (04): : 156 - 159
  • [36] Transient model and simulation in three-phase three-limb transformers
    Cheng Kung Univ, Tainan, Taiwan
    IEEE Trans Power Delivery, 2 (896-905):
  • [37] Transients in three-phase transformers, Three-wire power system
    Khalikov, V.A. (xva@nm.ru), 1600, Institute of Electrodynamics, Peremogy 56,, Kyiv-57,, 03680, Ukraine
  • [38] Effects of voltage sags on three-phase three-legged transformers
    Guasch, L
    Córcoles, F
    Pedra, J
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 571 - 576
  • [39] DC to three-phase inverter based on two-phase to three-phase transformation
    Milanovic, M
    Dolinar, D
    Ravnjak, A
    ISIE 2002: PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-4, 2002, : 784 - 788
  • [40] Multiobjective Optimization Techniques Applied to Three-Phase Transformers Designs
    Maximiano Sobrinho, Adelicio
    Camacho, Jose Roberto
    Carvalho, Rafael Lima
    Rivera Sanhueza, Sergio Manuel
    Leal de Freitas, Stefani Carolline
    IEEE LATIN AMERICA TRANSACTIONS, 2022, 20 (03) : 386 - 394