Management of the Left Subclavian Artery during TEVAR

被引:91
作者
Feezor, Robert J. [1 ]
Lee, W. Anthony [1 ]
机构
[1] Univ Florida, Div Vasc Surg & Endovasc Therapy, Gainesville, FL 32610 USA
关键词
ENDOVASCULAR AORTIC REPAIR; STENT-GRAFT; ENDOLUMINAL REPAIR; THORACIC AORTA; RISK-FACTORS; COVERAGE; PATHOLOGY; OCCLUSION; REVASCULARIZATION; TRANSPOSITION;
D O I
10.1053/j.semvascsurg.2009.07.007
中图分类号
R61 [外科手术学];
学科分类号
摘要
The proximity of thoracic aortic pathologies to the left subclavian artery has occasionally required intentional coverage of this vessel. With increased collective experience with thoracic endovascular techniques, indications for revascularization in this setting have evolved. Coverage of the left subclavian artery without revascularization has been associated with left arm claudication, spinal cord ischemia, posterior circulation strokes, and, in certain instances, myocardial ischemia. The occurrence of these events has not been uniform and, in some patients, the left subclavian artery can be covered without significant clinical sequelae. In this review, we discuss the incidence of these complications, their risk factors, and indications for elective revascularization of the left subclavian artery during thoracic endovascular aortic repair. Semin Vasc Surg 22:159-164 (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 21 条
[1]   Double-Barrel Technique for Preservation of Aortic Arch Branches During Thoracic Endovascular Aortic Repair [J].
Baldwin, Z. K. ;
Chuter, T. A. M. ;
Hiramoto, J. S. ;
Reilly, L. M. ;
Schneider, D. B. .
ANNALS OF VASCULAR SURGERY, 2008, 22 (06) :703-709
[2]   Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. A study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) Registry [J].
Buth, Jacob ;
Harris, Peter L. ;
Hobo, Roel ;
van Eps, Randolph ;
Cuypers, Philippe ;
Duijm, Lucien ;
Tielbeek, Xander .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (06) :1103-1111
[3]   Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease [J].
Caronno, R. ;
Piffaretti, G. ;
Tozzi, M. ;
Lomazzi, C. ;
Rivolta, N. ;
Castelli, P. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06) :915-918
[4]   Subclavian carotid transposition and bypass grafting:: Consecutive cohort study and systematic review [J].
Cinà, CS ;
Safar, HA ;
Laganà, A ;
Arena, G ;
Clase, CM .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (03) :422-429
[5]   Neurological complications after left subclavian artery coverage during thoracic endovascular aortic repair: A systematic review and meta-analysis [J].
Cooper, David G. ;
Walsh, Stewart R. ;
Sadat, Umar ;
Noorani, Ayesha ;
Hayes, Paul D. ;
Boyle, Jonathan R. .
JOURNAL OF VASCULAR SURGERY, 2009, 49 (06) :1594-1601
[6]   A percutaneous technique for preservation of arch branch patency during thoracic endovascular aortic repair (TEVAR): Retrograde catheterization and stenting [J].
Criado, Frank J. .
JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (01) :54-58
[7]  
Dunning Joel, 2008, Interact Cardiovasc Thorac Surg, V7, P690, DOI 10.1510/icvts.2008.181222
[8]  
Feezor RJ, 2007, J ENDOVASC THER, V14, P568, DOI 10.1583/1545-1550(2007)14[568:RFFPSD]2.0.CO
[9]  
2
[10]   JOINT STUDY OF EXTRACRANIAL ARTERIAL OCCLUSION .7. SUBCLAVIAN STEAL - REVIEW OF 168 CASES [J].
FIELDS, WS ;
LEMAK, NA .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 222 (09) :1139-&