Aptamer-based sensor arrays for the detection and quantitation of proteins

被引:260
作者
Kirby, R
Cho, EJ
Gehrke, B
Bayer, T
Park, YS
Neikirk, DP
McDevitt, JT
Ellington, AD [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
[2] Univ Texas, Dept Elect & Comp Engn, Austin, TX 78712 USA
[3] Univ Texas, Inst Cell & Mol Biol, Austin, TX 78712 USA
关键词
D O I
10.1021/ac049858n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aptamer biosensors have been immobilized on beads, introduced into micromachined chips on the electronic tongue sensor array, and used for the detection and quantitation of proteins. Aptamer chips could detect proteins in both capture and sandwich assay formats. Unlike most protein-based arrays, the aptamer chips could be stripped and reused multiple times. The aptamer chips proved to be useful for screening aptamers from in vitro selection experiments and for sensitively quantitating the biothreat agent ricin.
引用
收藏
页码:4066 / 4075
页数:10
相关论文
共 46 条
  • [1] DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays
    Ali, MF
    Kirby, R
    Goodey, AP
    Rodriguez, MD
    Ellington, AD
    Neikirk, DP
    McDevitt, JT
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (18) : 4732 - 4739
  • [2] Kinetic and thermodynamic basis of promoter strength: Multiple steps of transcription initiation by T7 RNA polymerase are modulated by the promoter sequence
    Bandwar, RP
    Jia, YP
    Stano, NM
    Patel, SS
    [J]. BIOCHEMISTRY, 2002, 41 (11) : 3586 - 3595
  • [3] Exploring the new world of the genome with DNA microarrays
    Brown, PO
    Botstein, D
    [J]. NATURE GENETICS, 1999, 21 (Suppl 1) : 33 - 37
  • [4] Structural basis for initiation of transcription from an RNA polymerase-promoter complex
    Cheetham, GMT
    Jeruzalmi, D
    Steitz, TA
    [J]. NATURE, 1999, 399 (6731) : 80 - 83
  • [5] A microchip-based multianalyte assay system for the assessment of cardiac risk
    Christodoulides, N
    Tran, M
    Floriano, PN
    Rodriguez, M
    Goodey, A
    Ali, M
    Neikirk, D
    McDevitt, JT
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (13) : 3030 - 3036
  • [6] Automated RNA selection
    Cox, JC
    Rudolph, P
    Ellington, AD
    [J]. BIOTECHNOLOGY PROGRESS, 1998, 14 (06) : 845 - 850
  • [7] Automated selection of anti-protein aptamers
    Cox, JC
    Ellington, AD
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY, 2001, 9 (10) : 2525 - 2531
  • [8] Enzyme-based sensor arrays for rapid characterization of complex disaccharide solutions
    Curey, TE
    Salazar, MA
    Oliveira, P
    Javier, J
    Dennis, PJ
    Rao, P
    Shear, JB
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 303 (01) : 42 - 48
  • [9] Characterization of multicomponent monosaccharide solutions using an enzyme-based sensor array
    Curey, TE
    Goodey, A
    Tsao, A
    Lavigne, J
    Sohn, Y
    McDevitt, JT
    Anslyn, EV
    Neikirk, D
    Shear, JB
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 293 (02) : 178 - 184
  • [10] Use of a high affinity DNA ligand in flow cytometry
    Davis, KA
    Abrams, B
    Lin, Y
    Jayasena, SD
    [J]. NUCLEIC ACIDS RESEARCH, 1996, 24 (04) : 702 - 706