Influence of polyelectrolyte capillary coating conditions on protein analysis in CE

被引:49
作者
Nehme, Reine [1 ]
Perrin, Catherine [1 ]
Cottet, Herve [1 ]
Blanchin, Marie-Dominique [1 ]
Fabre, Huguette [1 ]
机构
[1] Univ Montpellier 1, Univ Montpellier 2, CNRS, Inst Biomol Max Mousseron,UMR,Fac Pharm,Lab Chim, F-34093 Montpellier 5, France
关键词
Adsorption prevention; Coating stability; Multilayer coating; Polyelectrolyte; Protein; ATOMIC-FORCE MICROSCOPY; FUSED-SILICA CAPILLARIES; PERFORMANCE LIQUID-CHROMATOGRAPHY; IONIC POLYMER LAYERS; ZONE-ELECTROPHORESIS; BASIC-PROTEINS; WALL COATINGS; BACKGROUND ELECTROLYTE; ELECTROOSMOTIC FLOW; COATED CAPILLARIES;
D O I
10.1002/elps.200800688
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
CE of biomolecules is limited by analyte adsorption on the capillary wall. To prevent this, monolayer or successive multiple ionic-polymer layers (SMILs) of highly charged polyelectrolytes can be physically adsorbed on the inner capillary surface. Although these coatings have become commonly used in CE, no systematic investigation of their performance under different coating conditions has been carried out so far. In a previous study (Nehme, R., Perrin, C., Cottet, H., Blanchin, M. D., Fabre, H., Electrophoresis 2008, 29, 3013-3023), we investigated the influence of different experimental parameters on coating stability, repeatability and peptide peak efficiency. Optimal coating conditions for monolayer and multilayer (SMILs) poly(diallyldimethylammonium) chloride/poly(sodium 4-styrenesulfonate) coated capillaries were determined. In this study, the influence of polyelectrolyte concentration and ionic strength of the coating solutions, and the number of coating layers on coating stability and performance in limiting protein adsorption was carried out. EOF magnitude and repeatability were used to monitor coating stability. Coating ability to limit protein adsorption was investigated by monitoring variations of migration times, time-corrected peak areas and separation efficiency of test proteins. The separation performance of polyelectrolyte coatings were compared with those obtained with bare silica capillaries.
引用
收藏
页码:1888 / 1898
页数:11
相关论文
共 50 条
[31]   Preparative capillary electrophoresis (CE) fractionation of protein digests improves protein and peptide identification in bottom-up proteomics [J].
Weaver, Simon D. ;
Schuster-Little, Naviya ;
Whelan, Rebecca J. .
ANALYTICAL METHODS, 2022, 14 (11) :1103-1110
[32]   Development of a method for the analysis of drugs of abuse in vitreous humor by capillary electrophoresis with diode array detection (CE-DAD) [J].
Costa, Jose Luiz ;
Morrone, Andre Ribeiro ;
Resende, Rodrigo Ribeiro ;
da Matta Chasin, Alice Aparecida ;
Maggi Tavares, Marina Franco .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 945 :84-91
[33]   A novel diazoresin/polystyrene-poly(ethylene oxide) covalent capillary coating for the analysis of proteins by capillary electrophoresis [J].
Zhou, Jian ;
Wu, Yue ;
Wei, Yan ;
Shen, You-Qing ;
Cong, Hai-Lin ;
Yu, Bing .
FERROELECTRICS, 2019, 548 (01) :15-25
[34]   Protein-Polyelectrolyte Interaction: Thermodynamic Analysis Based on the Titration Method [J].
Wang, Xiaohan ;
Zheng, Kai ;
Si, Yi ;
Guo, Xuhong ;
Xu, Yisheng .
POLYMERS, 2019, 11 (01)
[35]   Surface deactivation in protein and peptide analysis by capillary electrophoresis [J].
Rodriguez, I ;
Li, SFY .
ANALYTICA CHIMICA ACTA, 1999, 383 (1-2) :1-26
[36]   Capillary electrophoresis and isoelectric focusing in peptide and protein analysis [J].
Righetti, Pier Giorgio ;
Sebastiano, Roberto ;
Citterio, Attilio .
PROTEOMICS, 2013, 13 (02) :325-340
[37]   Recent advances in protein analysis by capillary and microchip electrophoresis [J].
Dawod, Mohamed ;
Arvin, Natalie E. ;
Kennedy, Robert T. .
ANALYST, 2017, 142 (11) :1847-1866
[38]   Protein-polyelectrolyte interactions: Monitoring particle formation and growth by nanoparticle tracking analysis and flow imaging microscopy [J].
Sediq, Ahmad S. ;
Nejadnik, M. Reza ;
El Bialy, Inas ;
Witkamp, Geert-Jan ;
Jiskoot, Wim .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2015, 93 :339-345
[39]   New multilayer coating using quaternary ammonium chitosan and κ-carrageenan in capillary electrophoresis: Application in fast analysis of betaine and methionine [J].
Vitali, Luciano ;
Della Betta, Fabiana ;
Costa, Ana Carolina O. ;
Simas Vaz, Fernando Antonio ;
Leal Oliveira, Marcone Augusto ;
Vistuba, Jacqueline Pereira ;
Favere, Valfredo T. ;
Micke, Gustavo A. .
TALANTA, 2014, 123 :45-53
[40]   Analysis of aristolochic acids by CE-MS with carboxymethyl chitosan-coated capillary [J].
Fu, Xiaofang ;
Liu, Yi ;
Li, Wei ;
Pang, Nannan ;
Nie, Honggang ;
Liu, Huwei ;
Cai, Zongwei .
ELECTROPHORESIS, 2009, 30 (10) :1783-1789