Influence of polyelectrolyte capillary coating conditions on protein analysis in CE

被引:47
|
作者
Nehme, Reine [1 ]
Perrin, Catherine [1 ]
Cottet, Herve [1 ]
Blanchin, Marie-Dominique [1 ]
Fabre, Huguette [1 ]
机构
[1] Univ Montpellier 1, Univ Montpellier 2, CNRS, Inst Biomol Max Mousseron,UMR,Fac Pharm,Lab Chim, F-34093 Montpellier 5, France
关键词
Adsorption prevention; Coating stability; Multilayer coating; Polyelectrolyte; Protein; ATOMIC-FORCE MICROSCOPY; FUSED-SILICA CAPILLARIES; PERFORMANCE LIQUID-CHROMATOGRAPHY; IONIC POLYMER LAYERS; ZONE-ELECTROPHORESIS; BASIC-PROTEINS; WALL COATINGS; BACKGROUND ELECTROLYTE; ELECTROOSMOTIC FLOW; COATED CAPILLARIES;
D O I
10.1002/elps.200800688
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
CE of biomolecules is limited by analyte adsorption on the capillary wall. To prevent this, monolayer or successive multiple ionic-polymer layers (SMILs) of highly charged polyelectrolytes can be physically adsorbed on the inner capillary surface. Although these coatings have become commonly used in CE, no systematic investigation of their performance under different coating conditions has been carried out so far. In a previous study (Nehme, R., Perrin, C., Cottet, H., Blanchin, M. D., Fabre, H., Electrophoresis 2008, 29, 3013-3023), we investigated the influence of different experimental parameters on coating stability, repeatability and peptide peak efficiency. Optimal coating conditions for monolayer and multilayer (SMILs) poly(diallyldimethylammonium) chloride/poly(sodium 4-styrenesulfonate) coated capillaries were determined. In this study, the influence of polyelectrolyte concentration and ionic strength of the coating solutions, and the number of coating layers on coating stability and performance in limiting protein adsorption was carried out. EOF magnitude and repeatability were used to monitor coating stability. Coating ability to limit protein adsorption was investigated by monitoring variations of migration times, time-corrected peak areas and separation efficiency of test proteins. The separation performance of polyelectrolyte coatings were compared with those obtained with bare silica capillaries.
引用
收藏
页码:1888 / 1898
页数:11
相关论文
共 50 条
  • [21] Coating with pH-responsive polyelectrolyte multilayers for the control of surface charge in capillary electrophoresis.
    Sui, ZJ
    Schlenoff, JB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U616 - U616
  • [22] Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips
    Liu, Y
    Fanguy, JC
    Bledsoe, JM
    Henry, CS
    ANALYTICAL CHEMISTRY, 2000, 72 (24) : 5939 - 5944
  • [23] Organic and inorganic di-cations for capillary silica coating and EOF modulation in CE: Example of application in PEG analysis
    Sebastiano, Roberto
    Mendieta, Martha Elena
    Antonioli, Paolo
    Bossi, Alessandra
    Righetti, Pier Giorgio
    Citterio, Attilio
    ELECTROPHORESIS, 2006, 27 (08) : 1495 - 1501
  • [24] Protein Purification by Polyelectrolyte Coacervation: Influence of Protein Charge Anisotropy on Selectivity
    Xu, Yisheng
    Mazzawi, Malek
    Chen, Kaimin
    Sun, Lianhong
    Dubin, Paul L.
    BIOMACROMOLECULES, 2011, 12 (05) : 1512 - 1522
  • [25] Protein purification by polyelectrolyte coacervation: Influence of protein charge anisotropy on selectivity
    Xu, Yisheng
    Dubin, Paul
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [26] Influence of protein charge patches on the structure of protein-polyelectrolyte complexes
    Samanta, Rituparna
    Ganesan, Venkat
    SOFT MATTER, 2018, 14 (46) : 9475 - 9488
  • [27] Analysis of capillary coating die flow in an optical fiber coating applicator
    Kim, Kyoungjin
    World Academy of Science, Engineering and Technology, 2011, 55 : 384 - 388
  • [28] ANALYSIS OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ELECTROPHORESIS - OPTIMIZATION OF PROTEIN SEPARATION CONDITIONS USING MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY
    BEATTIE, JH
    RICHARDS, MP
    JOURNAL OF CHROMATOGRAPHY A, 1995, 700 (1-2) : 95 - 103
  • [29] Analysis of protein-digested mixture with dynamic coating capillary electrophoresis-mass spectrometry
    Wang, XY
    Mou, XD
    Xu, YM
    Yang, PY
    Wang, HH
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (07): : 1226 - 1230
  • [30] INFLUENCE OF POLYMER COATING OF CAPILLARY SURFACES ON MIGRATION BEHAVIOR IN MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY
    LUX, JA
    YIN, H
    SCHOMBURG, G
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1990, 13 (02): : 145 - 147