Structural implications of fenestrated stent graft misalignment

被引:10
作者
Crawford, S. A. [1 ,2 ]
Itkina, M. [3 ]
Doyle, M. G. [4 ]
Tse, L. W. [2 ]
Amon, C. H. [1 ,4 ]
Roche-Nagle, G. [2 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, 164 Coll St,Room 164, Toronto, ON M5S 13G9, Canada
[2] UHN, Toronto Gen Hosp, Div Vasc Surg, 190 Elizabeth St, Toronto, ON M5G 2C4, Canada
[3] Univ Toronto, Div Engn Sci, 35 St George St, Toronto, ON M5S 1A4, Canada
[4] Univ Toronto, Dept Mech & Ind Engn, 5 Kings Coll Rd, Toronto, ON M5S 3G8, Canada
来源
SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND | 2018年 / 16卷 / 02期
关键词
Abdominal aortic aneurysm; Fenestrated; Stent graft; Endograft; EVAR; Endovascular aneurysm repair; Misalignment; OFF-THE-SHELF; THORACOABDOMINAL AORTIC-ANEURYSMS; CUSTOM-MADE; ENDOGRAFTS; FORCES; REPAIR; BRANCH;
D O I
10.1016/j.surge.2016.08.001
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Endovascular aneurysm repair is a minimally-invasive method for the treatment of abdominal aortic aneurysms. For aneurysms that involve the visceral arteries, a custom-made stent graft with fenestrations for the branch arteries is required. The purpose of the current study is to evaluate the structural impact of misaligned fenestrations with respect to luminal patency and proximal aortic neck apposition in an in vitro model. Methods: A custom apparatus was used to evaluate seven Anaconda and three Zenith fenestrated stent grafts. All stent grafts were evaluated at 10 degrees increments of stent/fenestration misalignment up to 80 degrees. Images were captured at each interval and the luminal cross-sectional area and wall apposition were measured. Results: The Anaconda stent graft, which has an unsupported main body, demonstrated a linear reduction in luminal patency at increasing angles of misalignment (P < 0.0001). Stent/fenestration misalignments of 20 degrees and 80 degrees resulted in decreases in mean luminal patency of 14% and 54% respectively. The Zenith stent graft demonstrated a similar decrease in luminal patency, starting at misalignments of >= 40 degrees (P < 0.0001). However, with stent/fenestration misalignments of >= 30 degrees, apposition between the Zenith stent graft and the simulated aortic neck was compromised suggesting the creation of a type Ia endoleak. Conclusions: Both the Anaconda and Zenith devices behave adversely at extreme angles of misalignment with luminal narrowing in the Anaconda device and loss of wall apposition in the Zenith device; however, both stent grafts appear to be equivalent at low angles of misalignment. (C) 2016 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 20 条
[1]  
[Anonymous], 2013, ANN VASC SURG
[2]   Off-the-Shelf Branched Endograft for Emergent Aneurysm Repair [J].
Barilla, David ;
Guillou, Matthieu ;
Maurel, Blandine ;
Sobocinski, Jonathan ;
Midulla, Marco ;
Tyrrell, Mark ;
Haulon, Stephan .
ANNALS OF VASCULAR SURGERY, 2013, 27 (07) :972.e11-972.e15
[3]   Custom-made versus off-the-shelf multibranched endografts for endovascular repair of thoracoabdominal aortic aneurysms [J].
Bisdas, Theodosios ;
Donas, Konstantinos P. ;
Bosiers, Michel J. ;
Torsello, Giovanni ;
Austermann, Martin .
JOURNAL OF VASCULAR SURGERY, 2014, 60 (05) :1186-1195
[4]   Early Experience With the First Commercially Available Off-the-Shelf Multibranched Endograft (t-Branch) in the Treatment of Thoracoabdominal Aortic Aneurysms [J].
Bosiers, Michel J. ;
Bisdas, Theodosios ;
Donas, Konstantinos P. ;
Torsello, Giovanni ;
Austermann, Martin .
JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (06) :719-725
[5]   Technical aspects, current indications, and results of chimney grafts for juxtarenal aortic aneurysms [J].
Coscas, Raphael ;
Kobeiter, Hicham ;
Desgranges, Pascal ;
Becquemin, Jean-Pierre .
JOURNAL OF VASCULAR SURGERY, 2011, 53 (06) :1520-1527
[6]   "Off-the-shelf" devices for complex aortic aneurysm repair [J].
Farber, Mark A. ;
Vallabhaneni, Raghuveer ;
Marston, William A. .
JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) :579-583
[7]   Standard off-the-shelf versus custom-made multibranched thoracoabdominal aortic stent grafts [J].
Fernandez, Charlene C. ;
Sobel, Julia D. ;
Gasper, Warren J. ;
Vartanian, Shant M. ;
Reilly, Linda M. ;
Chuter, Timothy A. M. ;
Hiramoto, Jade S. .
JOURNAL OF VASCULAR SURGERY, 2016, 63 (05) :1208-1215
[8]   The Hemodynamic Impact of Misalignment of Fenestrated Endografts: A Computational Study [J].
Georgakarakos, E. ;
Xenakis, A. ;
Georgiadis, G. S. ;
Argyriou, C. ;
Antoniou, G. A. ;
Schoretsanitis, N. ;
Lazarides, M. K. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (02) :151-159
[9]   Systematic Review of Off-the-Shelf or Physician-Modified Fenestrated and Branched Endografts [J].
Georgiadis, George S. ;
van Herwaarden, Joost A. ;
Antoniou, George A. ;
Hazenberg, Constantijn E. V. B. ;
Giannoukas, Athanasios D. ;
Lazarides, Miltos K. ;
Moll, Frans L. .
JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (01) :98-109
[10]   Patient-specific analysis of displacement forces acting on fenestrated stent grafts for endovascular aneurysm repair [J].
Kandail, Harkamaljot ;
Hamady, Mohammad ;
Xu, Xiao Yun .
JOURNAL OF BIOMECHANICS, 2014, 47 (14) :3546-3554