Simple and Reliable HPLC Method for the Monitoring of Methotrexate in Osteosarcoma Patients

被引:39
作者
Begas, Elias [1 ]
Papandreou, Christos [2 ]
Tsakalof, Andreas [3 ]
Daliani, Danai [2 ]
Papatsibas, George [2 ]
Asprodini, Eftihia [1 ]
机构
[1] Univ Thessaly, Sch Med, Pharmacol Lab, Volos, Greece
[2] Univ Thessaly, Sch Med, Dept Med Oncol, Volos, Greece
[3] Univ Thessaly, Sch Med, Chem Lab, Volos, Greece
关键词
HIGH-DOSE METHOTREXATE; PERFORMANCE LIQUID-CHROMATOGRAPHY; PROTEIN-BINDING ASSAY; RHEUMATOID-ARTHRITIS; CITROVORUM FACTOR; PHARMACOKINETICS; PLASMA; PHARMACODYNAMICS; QUANTITATION; METABOLITES;
D O I
10.1093/chromsci/bmt081
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methotrexate (MTX) is a dihydrofolate reductase inhibitor that is used for the treatment of tumors and autoimmune diseases. Several automated binding assays are used in clinical practice and numerous chromatographic methods have been developed toward higher specificity and sensitivity. In the present study, phenyl cartridges were used for the solid-phase extraction (SPE) of MTX from human serum samples; subsequently, extracts were analyzed by reversed-phase high-performance liquid chromatography. Isocratic separation was implemented on a Kromasil-C18 column with a mobile phase consisting of 50 mM sodium acetate buffer (pH 3.6)-acetonitrile (89:11, v/v) and ultraviolet detection at 307 nm. MTX eluted in less than 12 min with no interference from impurities or 24 examined drugs. Detector response was linear in the range of 0.025-5.00 mu M (coefficient of correlation > 0.99). Recovery from the serum was 93.1-98.2% and bias was < 8.3%. Intra-day and inter-day precision were < 7.8 and 12.6%, respectively (n = 6). The limit of quantitation was 0.01 mu M and the limit of detection was 0.003 mu M. The method was validated by using serum samples from osteosarcoma patients treated with high-dose MTX (8-12 g/m(2)). In conclusion, the combined use of a phenyl-functionalized sorbent for SPE and a Kromasil-C18 column, and specific detection at 307 nm, assured a selective, fast, robust and cost-effective method for the monitoring of MTX in osteosarcoma patients under high-dose MTX treatment, thus contributing to more efficient treatment.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 32 条
[1]   SIMULTANEOUS QUANTITATION OF METHOTREXATE AND ITS 2 MAIN METABOLITES IN BIOLOGICAL-FLUIDS BY A NOVEL SOLID-PHASE EXTRACTION PROCEDURE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALBERTIONI, F ;
PETTERSSON, B ;
BECK, O ;
RASK, C ;
SEIDEMAN, P ;
PETERSON, C .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01) :163-170
[2]   Clinical pharmacokinetics of low-dose pulse methotrexate in rheumatoid arthritis [J].
Bannwarth, B ;
Pehourcq, F ;
Schaeverbeke, T ;
Dehais, J .
CLINICAL PHARMACOKINETICS, 1996, 30 (03) :194-210
[3]   Pharmacokinetics and pharmacodynamics of low-dose methotrexate in the treatment of psoriasis [J].
Chládek, J ;
Grim, J ;
Martínková, J ;
Simková, M ;
Vanìèková, J ;
Koudelková, V ;
Noièková, M .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2002, 54 (02) :147-156
[5]   A U-HPLC-ESI-MS/MS-Based Stable Isotope Dilution Method for the Detection and Quantitation of Methotrexate in Plasma [J].
den Boer, Ethan ;
Heil, Sandra G. ;
van Zelst, Bertrand D. ;
Meesters, Roland J. W. ;
Koch, Birgit C. P. ;
te Winkel, Mariel L. ;
van den Heuvel-Eibrink, Marry M. ;
Luider, Theo M. ;
de Jonge, Robert .
THERAPEUTIC DRUG MONITORING, 2012, 34 (04) :432-439
[6]   HPLC determination of erythrocyte methotrexate polyglutamates after low-dose methotrexate therapy in patients with rheumatoid arthritis [J].
Dervieux, T ;
Lein, DO ;
Marcelletti, J ;
Pischel, K ;
Smith, K ;
Walsh, M ;
Richerson, R .
CLINICAL CHEMISTRY, 2003, 49 (10) :1632-1641
[7]  
DJERASSI I, 1977, CANCER TREAT REP, V61, P749
[8]   A REEVALUATION OF THE COMPETITIVE-PROTEIN-BINDING ASSAY FOR METHOTREXATE BINDING TO DIHYDROFOLATE-REDUCTASE [J].
DRAKE, JC ;
ALLEGRA, CJ ;
CHABNER, BA .
BIOCHEMICAL PHARMACOLOGY, 1986, 35 (07) :1212-1214
[9]   High-dose methotrexate in adults with osteosarcoma: a population pharmacokinetics study and validation of a new limited sampling strategy [J].
Dupuis, Charlotte ;
Mercier, Cedric ;
Yang, Chenguang ;
Monjanel-Mouterde, Suzanne ;
Ciccolini, Joseph ;
Fanciullino, Raphaelle ;
Pourroy, Bertrand ;
Deville, Jean-Laurent ;
Duffaud, Florence ;
Bagarry-Liegey, Danielle ;
Durand, Alain ;
IIiadis, Athanassios ;
Favre, Roger .
ANTI-CANCER DRUGS, 2008, 19 (03) :267-273
[10]   METHOTREXATE IN RHEUMATOID-ARTHRITIS - A LIMITED SAMPLING STRATEGY FOR ESTIMATION OF THE AREA UNDER THE PLASMA-CONCENTRATION VERSUS TIME CURVE [J].
EKSBORG, S ;
ALBERTIONI, F ;
BECK, O ;
PETERSON, C ;
SEIDEMAN, P .
THERAPEUTIC DRUG MONITORING, 1994, 16 (06) :560-563