Capsule-like voids in SiC single crystal: Phase contrast imaging and computer simulations

被引:3
作者
Kohn, V. G. [1 ]
Argunova, T. S. [2 ]
Je, J. H. [3 ]
机构
[1] Natl Res Ctr Kurchatov Inst, Moscow 123182, Russia
[2] RAS, Ioffe Phys Tech Inst, St Petersburg 194021, Russia
[3] Pohang Univ Sci & Technol, Xray Imaging Ctr, Dept Mat Sci & Engn, Pohang 790784, South Korea
来源
AIP ADVANCES | 2014年 / 4卷 / 09期
关键词
SYNCHROTRON-RADIATION BEAM; SILICON-CARBIDE; SUBLIMATION GROWTH; X-RAYS; MICROPIPES; IMAGES; RADIOGRAPHY; TOMOGRAPHY; EVOLUTION;
D O I
10.1063/1.4896512
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The results of observation of capsule-like voids in silicon carbide (6H-SiC) single crystal by means of a phase contrast imaging technique with synchrotron radiation at the Pohang Light Source as well as computer simulations of such images are presented. A pink beam and a monochromated beam were used. The latter gives more pronounced images but they still are smoothed due to a finite detector resolution and the spatial coherence of the beam. Sizes and a structure of far field images are different from these of the objects. The computer simulations allow us to reproduce a shape and a size of the capsule-like void. (C) 2014 Author(s).
引用
收藏
页数:7
相关论文
共 34 条
[21]   Single-shot x-ray phase-contrast and dark-field imaging based on coded binary phase mask [J].
Qiao, Zhi ;
Shi, Xianbo ;
Wojcik, Michael J. ;
Rebuffi, Luca ;
Assoufid, Lahsen .
APPLIED PHYSICS LETTERS, 2021, 119 (01)
[22]   Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector [J].
Krejci, Frantisek ;
Jakubek, Jan ;
Kroupa, Martin .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (11)
[23]   Gauging low-dose X-ray phase-contrast imaging at a single and large propagation distance [J].
Hofmann, Ralf ;
Schober, Alexander ;
Hahn, Steffen ;
Moosmann, Julian ;
Kashef, Jubin ;
Hertel, Madeleine ;
Weinhardt, Venera ;
Haenschke, Daniel ;
Helfen, Lukas ;
Salazar, Ivan A. Sanchez ;
Guigay, Jean-Pierre ;
Xiao, Xianghui ;
Baumbach, Tilo .
OPTICS EXPRESS, 2016, 24 (04) :4331-4348
[24]   Inverted Hartmann mask for single-shot phase-contrast x-ray imaging of dynamic processes [J].
Zakharova, Margarita ;
Reich, Stefan ;
Mikhaylov, Andrey ;
Vlnieska, Vitor ;
Rolo, Tomy dos Santos ;
Plech, Anton ;
Kunka, Danays .
OPTICS LETTERS, 2019, 44 (09) :2306-2309
[25]   Simultaneous Imaging of Gas Phase over and Surface Reflectance of a Pd(100) Single Crystal during CO Oxidation [J].
Zhou, Jianfeng ;
Blomberg, Sara ;
Gustafson, Johan ;
Lundgren, Edvin ;
Zetterberg, Johan .
JOURNAL OF PHYSICAL CHEMISTRY C, 2017, 121 (42) :23511-23519
[26]   Single-shot grating-based X-ray phase contrast imaging via generative adversarial network [J].
Xu, Yueshu ;
Tao, Siwei ;
Bian, Yinxu ;
Bai, Ling ;
Tian, Zonghan ;
Hao, Xiang ;
Kuang, Cuifang ;
Liu, Xu .
OPTICS AND LASERS IN ENGINEERING, 2022, 152
[27]   Crystal-Based X-ray Interferometry and Its Application to Phase-Contrast X-ray Imaging, Zeff Imaging, and X-ray Thermography [J].
Yoneyama, Akio ;
Takamatsu, Daiko ;
Lwin, Thet-Thet ;
Yamada, Shigehito ;
Takakuwa, Tetsuya ;
Hyodo, Kazuyuki ;
Hirano, Keiichi ;
Takeya, Satoshi .
APPLIED SCIENCES-BASEL, 2023, 13 (09)
[28]   Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens [J].
Ando, Masami ;
Sunaguchi, Naoki ;
Wu, Yanlin ;
Synho Do ;
Sung, Yongjin ;
Louissaint, Abner ;
Yuasa, Tetsuya ;
Ichihara, Shu ;
Gupta, Rajiv .
EUROPEAN RADIOLOGY, 2014, 24 (02) :423-433
[29]   Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens [J].
Masami Ando ;
Naoki Sunaguchi ;
Yanlin Wu ;
Synho Do ;
Yongjin Sung ;
Abner Louissaint ;
Tetsuya Yuasa ;
Shu Ichihara ;
Rajiv Gupta .
European Radiology, 2014, 24 :423-433
[30]   Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging [J].
Krejci, F. ;
Jakubek, J. ;
Kroupa, M. .
JOURNAL OF INSTRUMENTATION, 2011, 6