NON-INVASIVE VASCULAR RADIAL/CIRCUMFERENTIAL STRAIN IMAGING AND WALL SHEAR RATE ESTIMATION USING VIDEO IMAGES OF DIAGNOSTIC ULTRASOUND

被引:16
作者
Wan, Jinjin [1 ]
He, Fangli [1 ]
Zhao, Yongfeng [2 ]
Zhang, Hongmei [1 ]
Zhou, Xiaodong [2 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Key Lab Biomed Informat Engn,Minist Educ, Xian 710049, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp, Dept Ultrasound, Xian 710032, Peoples R China
基金
中国国家自然科学基金;
关键词
Carotid; Atherosclerosis; Routine screening; Gray-scale correction; Radial strain; Circumferential strain; Transverse Doppler; Wall shear rate; IN-VIVO; INTRAVASCULAR ULTRASOUND; MYOCARDIAL ELASTOGRAPHY; BLOOD-FLOW; ELASTICITY; ATHEROSCLEROSIS; ARTERY; DISPLACEMENT; STRESS; RESOLUTION;
D O I
10.1016/j.ultrasmedbio.2013.10.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future. (E-mail:mxwan@mail.xjtu.edu.cn) (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:622 / 636
页数:15
相关论文
共 51 条
  • [1] A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries
    Baldewsing, RA
    De Korte, CL
    Schaar, JA
    Mastik, F
    Van Der Steen, AFW
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (06) : 803 - 813
  • [2] ARFI IMAGING FOR NONINVASIVE MATERIAL CHARACTERIZATION OF ATHEROSCLEROSIS PART II: TOWARD IN VIVO CHARACTERIZATION
    Behler, Russell H.
    Nichols, Timothy C.
    Zhu, Hongtu
    Merricks, Elizabeth P.
    Gallippi, Caterina M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (02) : 278 - 295
  • [3] Target detectability in acoustic elastography
    Bilgen, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) : 1128 - 1133
  • [4] A NONINVASIVE METHOD TO ESTIMATE WALL SHEAR RATE USING ULTRASOUND
    BRANDS, PJ
    HOEKS, APG
    HOFSTRA, L
    RENEMAN, RS
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) : 171 - 185
  • [5] THE LAPLACIAN PYRAMID AS A COMPACT IMAGE CODE
    BURT, PJ
    ADELSON, EH
    [J]. IEEE TRANSACTIONS ON COMMUNICATIONS, 1983, 31 (04) : 532 - 540
  • [6] REDUCTION OF IMAGE NOISE IN ELASTOGRAPHY
    CESPEDES, I
    OPHIR, J
    [J]. ULTRASONIC IMAGING, 1993, 15 (02) : 89 - 102
  • [7] Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling - Molecular, cellular, and vascular behavior
    Chatzizisis, Yiannis S.
    Coskun, Ahmet Umit
    Jonas, Michael
    Edelman, Elazer R.
    Feldman, Charles L.
    Stone, Peter H.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) : 2379 - 2393
  • [8] Vascular ultrasound for atherosclerosis imaging
    de Korte, Chris L.
    Hansen, Hendrik H. G.
    van der Steen, Anton F. W.
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 565 - 575
  • [9] Consensus concerning the morphology and the risk of carotid plaques
    DeBray, JM
    Baud, JM
    Dauzat, M
    [J]. CEREBROVASCULAR DISEASES, 1997, 7 (05) : 289 - 296
  • [10] Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms
    deKorte, CL
    Cespedes, EI
    vanderSteen, AFW
    Lancee, CT
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) : 735 - 746