Fire design method for bar-reinforced circular and elliptical concrete filled tubular columns

被引:32
作者
Espinos, Ana [1 ]
Romero, Manuel L. [1 ]
Hospitaler, Antonio [1 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, E-46071 Valencia, Spain
关键词
Fire resistance; Concrete filled tubular columns; Eurocode; 4; Simple calculation model; Reinforcement; Elliptical hollow section; STEEL COLUMNS; HOLLOW SECTIONS; STUB COLUMNS; RESISTANCE; BEHAVIOR; MODEL;
D O I
10.1016/j.engstruct.2013.05.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A method for calculating the design axial buckling load in the fire situation of unreinforced axially loaded concrete filled circular hollow section columns was presented by the authors in a previous paper [1]. In the present paper, the method is extended to bar-reinforced columns of circular and elliptical cross-section, as a necessary continuation to complete the proposal. The method presented here is based on the guidelines of Clause 4.3.5.1 in Eurocode 4 Part 1.2 for the fire design of composite columns and is developed on the basis of the results of new parametric studies, with varying values of the outer diameter of the column, steel tube wall thickness, relative slenderness, percentage of reinforcement and fire exposure time. From the results of these parametric studies, appropriate expressions and tables for the different parts which integrate the design method are derived. The proposed method is valid for centrally loaded bar-reinforced circular and elliptical concrete filled tubular columns, with a maximum percentage of reinforcement of a 5% and makes allowance for columns with a high slenderness, extending the current limits of Eurocode 4 Part 1.2. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:384 / 395
页数:12
相关论文
共 33 条
[21]   Performance-based fire resistance design of concrete-filled steel columns [J].
Kodur, VKR .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 51 (01) :21-36
[22]   Behaviour of Axially Loaded Concrete Filled Stainless Steel Elliptical Stub Columns [J].
Lam, D. ;
Gardner, L. ;
Burdett, M. .
ADVANCES IN STRUCTURAL ENGINEERING, 2010, 13 (03) :493-500
[23]  
Leskela MV, 2009, STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, P489
[24]  
Park S, 2007, STEEL STRUCT, V7, P183
[25]   A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads [J].
Park, Su-Hee ;
Choi, Sung-Mo ;
Chung, Kyung-Soo .
STEEL AND COMPOSITE STRUCTURES, 2008, 8 (06) :491-510
[26]  
Renaud C., 2004, IMPROVEMENT EXTENSIO
[27]   Fire behavior of axially loaded slender high strength concrete-filled tubular columns [J].
Romero, Manuel L. ;
Moliner, V. ;
Espinos, A. ;
Ibanez, C. ;
Hospitaler, A. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (12) :1953-1965
[28]   Finite element numerical evaluation of elliptical hollow section steel columns in fire [J].
Scullion, Tom ;
Ali, Faris ;
Nadjai, Ali .
THIN-WALLED STRUCTURES, 2012, 55 :22-36
[29]   Experimental study on performance of elliptical section steel columns, under hydrocarbon fire [J].
Scullion, Tom ;
Ali, Faris ;
Nadjai, All .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (06) :986-991
[30]  
Wang Y.C., 2008, STRUCT ENG, V7, P40