Experimental fusion of the sheep cervical spine.: Part I:: Effect of cage design on interbody fusion

被引:0
|
作者
Kandziora, F [1 ]
Pflugmacher, R [1 ]
Scholz, M [1 ]
Schäfer, J [1 ]
Schollmeier, G [1 ]
Schnake, KJ [1 ]
Bail, H [1 ]
Duda, G [1 ]
Haas, NP [1 ]
机构
[1] Humboldt Univ, Klinikum Charite, D-13353 Berlin, Germany
来源
CHIRURG | 2002年 / 73卷 / 09期
关键词
cervical spine; sheep; animal model; interbody fusion; cages; design; biomechanics;
D O I
10.1007/s00104-002-0489-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction. There has been a rapid increase in the use of interbody fusion cages as an adjunct to spondylodesis, although experimental data are lacking. A sheep cervical spine interbody fusion model was used to determine the effect of different cage design parameters (endplate-implant contact area, maximum contiguous pore) on interbody fusion. Material and Method. In vitro evaluation: 24 sheep cadaver specimens (C2-C5) were tested in flexion, extension, axial rotation, and lateral bending with a nondestructive flexibility method using a non-constrained testing apparatus. Four different groups were examined: (1) control group (intact) (n=24), (2) autologous tricortical iliac crest bone graft (n=8),(3) Harms cage (n=8), and (4) SynCage-C (n=8). In vivo evaluation: 24 sheep underwent C3/4 discectomy and fusion: group 1: autologous tricortical iliac crest bone graft (n=8), group 2: Harms cage filled with autologous cancellous iliac crest bone grafts (n=8), and group 3: SynCage-C filled with autologous cancellous iliac crest bone grafts (n=8). Radiographic scans were performed pre- and postoperatively and after 1, 2,4,8, and 12 weeks, respectively. At the same time points, disc space height (DSH), height index (HI), intervertebral angle (IVA), and endplate angle (EA) were measured. After 12 weeks the animals were killed and fusion sites were evaluated using biomechanical testing in flexion, extension, axial rotation, and lateral bending. Additionally, histomorphological and histomorphometrical analyses were performed. Results. Over a 12-week period the cage groups showed significantly higher values for DSH, HI, IVA, and EA compared to the bone graft. In vivo stiffness was significantly higher for the tricortical iliac crest bone graft and Harms cage than in vitro stiffness. However, there was no difference between in vitro and in vivo stiffness of the SynCage-C. Histomorphometrical evaluation showed a more progressed bone matrix formation in the Harms cage group than in both other groups. Conclusion. The parameter endplate-implant contact area was not able to determine subsidence of cages. In contrast,the maximum contiguous pore of a cage significantly correlates with interbody bone matrix formation inside the cage. Additionally, there was no correlation between in vitro and in vivo stiffness of interbody fusion cages. Therefore, biomechanical in vitro studies are not able to determine in vivo outcome of fusion cages. Animal experimental evaluations of interbody fusion cages are essential prior to clinical use.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 50 条
  • [41] Design process of custom-fitted interbody cage for lumbar spinal fusion
    Bounabi, M.
    Benabid, Y.
    Messellek, A. C.
    Azzouz, A.
    Abid, S.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 : 27 - 28
  • [42] Finite element analysis of cervical spine plate using double cage fusion
    Chen, Bingzhi
    Zhao, Wei
    Wang, Yuedong
    Xie, Suming
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [43] Guideline update for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 8: Lumbar fusion for disc herniation and radiculopathy
    Wang, Jeffrey C.
    Dailey, Andrew T.
    Mummaneni, Praveen V.
    Ghogawala, Zoher
    Resnick, Daniel K.
    Watters, William C., III
    Groff, Michael W.
    Choudhri, Tanvir F.
    Eck, Jason C.
    Sharan, Alok
    Dhall, Sanjay S.
    Kaiser, Michael G.
    JOURNAL OF NEUROSURGERY-SPINE, 2014, 21 (01) : 48 - 53
  • [44] An update of interbody cages for spine fusion surgeries: from shape design to materials
    Li, Guangshen
    Yang, Lei
    Wu, Gang
    Qian, Zhanyang
    Li, Haijun
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (12) : 977 - 989
  • [45] Lumbar interbody fusion: a parametric investigation of a novel cage design with and without posterior instrumentation
    Fabio Galbusera
    Hendrik Schmidt
    Hans-Joachim Wilke
    European Spine Journal, 2012, 21 : 455 - 462
  • [46] Lumbar interbody fusion: a parametric investigation of a novel cage design with and without posterior instrumentation
    Galbusera, Fabio
    Schmidt, Hendrik
    Wilke, Hans-Joachim
    EUROPEAN SPINE JOURNAL, 2012, 21 (03) : 455 - 462
  • [47] Influence of design and implantation technique on the risk of progressive subsidence of different cervical interbody fusion devices
    Furderer, S
    Schöllhuber, F
    Rompe, JD
    Eysel, R
    ORTHOPADE, 2002, 31 (05): : 466 - 471
  • [48] Effectiveness of a Fully Impregnated Hydroxyapatite Polyetheretherketone Cage on Fusion in Anterior Cervical Spine Surgery
    Chin, Kingsley R.
    Gohel, Nishant N.
    Aloise, Daniel M.
    Seale, Jason A.
    Pandey, Deepak K.
    Pencle, Fabio J.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [49] Long-term results in 57 patients with anterior interbody fusion of the lower cervical spine
    Blauth, M
    Schmidt, U
    Dienst, M
    Knop, C
    Lobenhoffer, P
    Tscherne, H
    UNFALLCHIRURG, 1996, 99 (12): : 925 - 939
  • [50] Porous interbody fusion cage design via topology optimization and biomechanical performance analysis
    Li, Nan
    Zhang, Yang
    Tang, Qiaohong
    Wang, Hongkun
    He, Da
    Yao, Yan
    Fan, Yubo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (06) : 650 - 659