Experimental fusion of the sheep cervical spine.: Part I:: Effect of cage design on interbody fusion

被引:0
|
作者
Kandziora, F [1 ]
Pflugmacher, R [1 ]
Scholz, M [1 ]
Schäfer, J [1 ]
Schollmeier, G [1 ]
Schnake, KJ [1 ]
Bail, H [1 ]
Duda, G [1 ]
Haas, NP [1 ]
机构
[1] Humboldt Univ, Klinikum Charite, D-13353 Berlin, Germany
来源
CHIRURG | 2002年 / 73卷 / 09期
关键词
cervical spine; sheep; animal model; interbody fusion; cages; design; biomechanics;
D O I
10.1007/s00104-002-0489-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction. There has been a rapid increase in the use of interbody fusion cages as an adjunct to spondylodesis, although experimental data are lacking. A sheep cervical spine interbody fusion model was used to determine the effect of different cage design parameters (endplate-implant contact area, maximum contiguous pore) on interbody fusion. Material and Method. In vitro evaluation: 24 sheep cadaver specimens (C2-C5) were tested in flexion, extension, axial rotation, and lateral bending with a nondestructive flexibility method using a non-constrained testing apparatus. Four different groups were examined: (1) control group (intact) (n=24), (2) autologous tricortical iliac crest bone graft (n=8),(3) Harms cage (n=8), and (4) SynCage-C (n=8). In vivo evaluation: 24 sheep underwent C3/4 discectomy and fusion: group 1: autologous tricortical iliac crest bone graft (n=8), group 2: Harms cage filled with autologous cancellous iliac crest bone grafts (n=8), and group 3: SynCage-C filled with autologous cancellous iliac crest bone grafts (n=8). Radiographic scans were performed pre- and postoperatively and after 1, 2,4,8, and 12 weeks, respectively. At the same time points, disc space height (DSH), height index (HI), intervertebral angle (IVA), and endplate angle (EA) were measured. After 12 weeks the animals were killed and fusion sites were evaluated using biomechanical testing in flexion, extension, axial rotation, and lateral bending. Additionally, histomorphological and histomorphometrical analyses were performed. Results. Over a 12-week period the cage groups showed significantly higher values for DSH, HI, IVA, and EA compared to the bone graft. In vivo stiffness was significantly higher for the tricortical iliac crest bone graft and Harms cage than in vitro stiffness. However, there was no difference between in vitro and in vivo stiffness of the SynCage-C. Histomorphometrical evaluation showed a more progressed bone matrix formation in the Harms cage group than in both other groups. Conclusion. The parameter endplate-implant contact area was not able to determine subsidence of cages. In contrast,the maximum contiguous pore of a cage significantly correlates with interbody bone matrix formation inside the cage. Additionally, there was no correlation between in vitro and in vivo stiffness of interbody fusion cages. Therefore, biomechanical in vitro studies are not able to determine in vivo outcome of fusion cages. Animal experimental evaluations of interbody fusion cages are essential prior to clinical use.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 50 条
  • [31] Pilot Study of a New Acrylic Cage in a Dog Cervical Spine Fusion Model
    Farrokhi, Majid Reza
    Torabinezhad, Simin
    Ghajar, Korush Azodi
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (04): : 272 - 277
  • [32] Long-term follow-up after interbody fusion of the cervical spine
    Goffin, J
    Geusens, E
    Vantomme, N
    Quintens, E
    Waerzeggers, Y
    Depreitere, B
    Van Calenbergh, F
    van Loon, J
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02): : 79 - 85
  • [33] Biomechanical analysis of an interbody cage with three integrated cancellous lag screws in a two-level cervical spine fusion construct: an in vitro study
    Nayak, Aniruddh N.
    Stein, Matthew I.
    James, Chris R.
    Gaskins, Roger B., III
    Cabezas, Andres F.
    Adu-Lartey, Maxwell
    Castellvi, Antonio E.
    Santoni, Brandon G.
    SPINE JOURNAL, 2014, 14 (12) : 3002 - 3010
  • [34] Outcome analyses of interbody titanium cage fusion used in the anterior discectomy for cervical degenerative disc disease
    Hwang, SL
    Hwang, YF
    Lieu, AS
    Lin, CL
    Kuo, TH
    Su, YF
    Howng, SL
    Lee, KS
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (04): : 326 - 331
  • [35] Effect of Elastic Modulus on Biomechanical Properties of Lumbar Interbody Fusion Cage
    Zhu, Yue
    Li, Fusheng
    Li, Shujun
    Hao, Yulin
    Yang, Rui
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2009, 25 (03) : 325 - 328
  • [37] Biomechanical effect of anterior cervical spine fusion on adjacent segments
    Maiman, DJ
    Kumaresan, S
    Yoganandan, N
    Pintar, FA
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1999, 9 (01) : 27 - 38
  • [38] Anterior corpectomy with iliac bone fusion or discectomy with interbody titanium cage fusion for multilevel cervical degenerated disc disease
    Hwang, Shiuh-Lin
    Lee, Kung-Shing
    Su, Yu-Feng
    Kuo, Tai-Hung
    Lieu, Ann-Shung
    Lin, Chih-Lung
    Howng, Shen-Long
    Hwang, Yan-Feng
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (08): : 565 - 570
  • [39] In vivo experimental study of hat type cervical intervertebral fusion cage (HCIFC)
    Gu, Yu-tong
    Yao, Zhen-jun
    Jia, Lian-shun
    Qi, Jin
    Wang, Jun
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1251 - 1259
  • [40] Design and Biomechanical Evaluation of a Bidirectional Expandable Cage for Oblique Lateral Interbody Fusion
    Wu, Yanfei
    Ma, Jianxiong
    Dai, Jing
    Wang, Ying
    Bai, Haohao
    Lu, Bin
    Chen, Jiahui
    Fan, Xiancheng
    Ma, Xinlong
    WORLD NEUROSURGERY, 2023, 180 : E644 - E652