Experimental fusion of the sheep cervical spine.: Part I:: Effect of cage design on interbody fusion

被引:0
|
作者
Kandziora, F [1 ]
Pflugmacher, R [1 ]
Scholz, M [1 ]
Schäfer, J [1 ]
Schollmeier, G [1 ]
Schnake, KJ [1 ]
Bail, H [1 ]
Duda, G [1 ]
Haas, NP [1 ]
机构
[1] Humboldt Univ, Klinikum Charite, D-13353 Berlin, Germany
来源
CHIRURG | 2002年 / 73卷 / 09期
关键词
cervical spine; sheep; animal model; interbody fusion; cages; design; biomechanics;
D O I
10.1007/s00104-002-0489-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction. There has been a rapid increase in the use of interbody fusion cages as an adjunct to spondylodesis, although experimental data are lacking. A sheep cervical spine interbody fusion model was used to determine the effect of different cage design parameters (endplate-implant contact area, maximum contiguous pore) on interbody fusion. Material and Method. In vitro evaluation: 24 sheep cadaver specimens (C2-C5) were tested in flexion, extension, axial rotation, and lateral bending with a nondestructive flexibility method using a non-constrained testing apparatus. Four different groups were examined: (1) control group (intact) (n=24), (2) autologous tricortical iliac crest bone graft (n=8),(3) Harms cage (n=8), and (4) SynCage-C (n=8). In vivo evaluation: 24 sheep underwent C3/4 discectomy and fusion: group 1: autologous tricortical iliac crest bone graft (n=8), group 2: Harms cage filled with autologous cancellous iliac crest bone grafts (n=8), and group 3: SynCage-C filled with autologous cancellous iliac crest bone grafts (n=8). Radiographic scans were performed pre- and postoperatively and after 1, 2,4,8, and 12 weeks, respectively. At the same time points, disc space height (DSH), height index (HI), intervertebral angle (IVA), and endplate angle (EA) were measured. After 12 weeks the animals were killed and fusion sites were evaluated using biomechanical testing in flexion, extension, axial rotation, and lateral bending. Additionally, histomorphological and histomorphometrical analyses were performed. Results. Over a 12-week period the cage groups showed significantly higher values for DSH, HI, IVA, and EA compared to the bone graft. In vivo stiffness was significantly higher for the tricortical iliac crest bone graft and Harms cage than in vitro stiffness. However, there was no difference between in vitro and in vivo stiffness of the SynCage-C. Histomorphometrical evaluation showed a more progressed bone matrix formation in the Harms cage group than in both other groups. Conclusion. The parameter endplate-implant contact area was not able to determine subsidence of cages. In contrast,the maximum contiguous pore of a cage significantly correlates with interbody bone matrix formation inside the cage. Additionally, there was no correlation between in vitro and in vivo stiffness of interbody fusion cages. Therefore, biomechanical in vitro studies are not able to determine in vivo outcome of fusion cages. Animal experimental evaluations of interbody fusion cages are essential prior to clinical use.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 50 条
  • [21] Anterior cervical interbody fusion using polyetheretherketone cage filled with synthetic bone graft in acute cervical spine injury
    Hattou, L.
    Morandi, X.
    Lefebvre, J.
    Le Reste, P. -J.
    Riffaud, L.
    Henaux, P. -L.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (01) : 61 - 66
  • [22] Biomechanical evaluation of a stand-alone interbody fusion cage based on porous TiO2/glass composites in the human cervical spine
    Korinth, MC
    Moersch, S
    Ragoss, C
    Schopphoff, E
    BIOMEDIZINISCHE TECHNIK, 2003, 48 (12): : 349 - 355
  • [23] Bioabsorbable Interbody Magnesium-Polymer Cage Degradation Kinetics, Biomechanical Stiffness, and Histological Findings From an Ovine Cervical Spine Fusion Model
    Daentzer, Dorothea
    Willbold, Elmar
    Kalla, Katharina
    Bartsch, Ivonne
    Masalha, Waseem
    Hallbaum, Maximiliane
    Hurschler, Christof
    Kauth, Theresa
    Kaltbeitzel, Daniel
    Hopmann, Christian
    Welke, Bastian
    SPINE, 2014, 39 (20) : E1220 - E1227
  • [24] Finite element analysis of anterior cervical spine interbody fusion
    Kumaresan, S
    Yoganandan, N
    Pintar, FA
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1997, 7 (04) : 221 - 230
  • [25] Dose-dependent effects of combined IGF-I and TGF-β1 application in a sheep cervical spine fusion model
    F. Kandziora
    R. Pflugmacher
    M. Scholz
    J. Schäfer
    G. Schollmeier
    G. Schmidmaier
    G. Duda
    M. Raschke
    N. P. Haas
    European Spine Journal, 2003, 12 : 464 - 473
  • [26] Comparison of BMP-2 and combined IGF-I/TGF-β1 application in a sheep cervical spine fusion model
    Kandziora, F
    Pflugmacher, R
    Scholz, M
    Knispel, C
    Hiller, T
    Schollmeier, G
    Bail, H
    Schmidmaier, G
    Duda, G
    Raschke, M
    Haas, NP
    EUROPEAN SPINE JOURNAL, 2002, 11 (05) : 482 - 493
  • [27] Dose-dependent effects of combined IGF-I and TGF-β1 application in a sheep cervical spine fusion model
    Kandziora, F
    Pflugmacher, R
    Scholz, M
    Schäfer, J
    Schollmeier, G
    Schmidmaier, G
    Duda, G
    Raschke, M
    Haas, NP
    EUROPEAN SPINE JOURNAL, 2003, 12 (05) : 464 - 473
  • [28] Anterior interbody fusion for cervical spine injuries - indications, implants, technique and results
    Blauth, M
    Schmidt, U
    Bastian, L
    Knop, C
    Tscherne, H
    ZENTRALBLATT FUR CHIRURGIE, 1998, 123 (08): : 919 - 929
  • [29] Strains in trussed spine interbody fusion implants are modulated by load and design
    Caffrey, Jason P.
    Alonso, Eloy
    Masuda, Koichi
    Hunt, Jessee P.
    Carmody, Cameron N.
    Ganey, Timothy M.
    Sah, Robert L.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 80 : 203 - 208
  • [30] Primary stabilizing effect of interbody fusion devices for the cervical spine: an in vitro comparison between three different cage types and bone cement
    H.-J. Wilke
    A. Kettler
    L. Claes
    European Spine Journal, 2000, 9 : 410 - 416