Dynamic monitoring and evaluation of bell ringing effects for the structural assessment of a masonry bell tower

被引:19
作者
Vincenzi, Loris [1 ]
Bassoli, Elisa [1 ]
Ponsi, Federico [1 ]
Castagnetti, Cristina [1 ]
Mancini, Francesco [1 ]
机构
[1] Univ Modena & Reggio Emilia, Dept Engn Enzo Ferrari DIEF, Modena, Italy
关键词
Dynamic monitoring; Bell swinging; FE model calibration; 3D geometrical survey; Masonry tower; NUMERICAL INSIGHTS; BEHAVIOR; IDENTIFICATION; OPTIMIZATION; REGISTRATION; STRATEGY; FORCES;
D O I
10.1007/s13349-019-00344-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents a rational procedure for the structural assessment of bell towers with respect to the dynamic actions induced by the bell ringing, based on structural monitoring and data processing. This methodology is tested on the bell tower of Saint Prospero (Reggio Emilia, Northern Italy), a masonry tower of great historical interest. The procedure includes an accurate geometrical survey for a deep knowledge of the structural geometry, which is the base for the structural modelling. A finite element model of the tower is calibrated with respect to the modal properties evaluated from the structural response measured in operational conditions. The structural response of the tower was also measured during a famous cultural event held in the city centre of Reggio Emilia, when skilled bell ringers played traditional melodies. The tower displacements are evaluated applying a double integration technique and a detrending procedure based on the empirical mode decomposition to the acquired accelerations. To simulate the structural response to the bell ringing, the tower and the bell are modelled as a single degree of freedom system and an unforced and undamped simple pendulum, respectively. For safety assessment purposes, the structural response of the tower is evaluated considering different oscillation angles in order to identify the one causing the maximum displacement. Finally, the stress pattern of the masonry caused by the bell-induced displacement is estimated thanks to the calibrated finite element model of the tower. Results show that the bell ringing causes a stress pattern lower than the allowable masonry strength for the serviceability conditions.
引用
收藏
页码:439 / 458
页数:20
相关论文
共 53 条
[1]   Recent trends in cultural heritage 3D survey: The photogrammetric computer vision approach [J].
Aicardi, Irene ;
Chiabrando, Filiberto ;
Lingua, Andrea ;
Noardo, Francesca .
JOURNAL OF CULTURAL HERITAGE, 2018, 32 :257-266
[2]   Numerical insights on the seismic risk of confined masonry towers [J].
Bartoli, Gianni ;
Betti, Michele ;
Galano, Luciano ;
Zini, Giacomo .
ENGINEERING STRUCTURES, 2019, 180 :713-727
[3]  
Bassoli Elisa, 2017, Key Engineering Materials, V747, P440, DOI 10.4028/www.scientific.net/KEM.747.440
[4]   Ambient vibration-based finite element model updating of an earthquake-damaged masonry tower [J].
Bassoli, Elisa ;
Vincenzi, Loris ;
D'Altri, Antonio Maria ;
de Miranda, Stefano ;
Forghieri, Marianna ;
Castellazzi, Giovanni .
STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (05)
[5]  
Bastonero P., 2014, ISPRS Annals of Photogrammetry, Remote Sensing and Spatial Information Sciences, VII-5, P73, DOI DOI 10.5194/ISPRSANNALS-II-5-73-2014
[6]   Dynamic behavior of a medieval masonry bell tower. II: Measurement and modeling of the tower motion [J].
Bennati, S ;
Nardini, L ;
Salvatore, W .
JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (11) :1656-1664
[7]   Dynamic behavior of a Medieval Masonry Bell Tower. Part I: Experimental measurements and modeling of Bell's dynamic actions [J].
Bennati, S ;
Nardini, L ;
Salvatore, W .
JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (11) :1647-1655
[8]   Optimized procedures and strategies for the dynamic monitoring of historical structures [J].
Boscato G. ;
Dal Cin A. ;
Ientile S. ;
Russo S. .
Journal of Civil Structural Health Monitoring, 2016, 6 (02) :265-289
[9]   Modal identification of output-only systems using frequency domain decomposition [J].
Brincker, R ;
Zhang, LM ;
Andersen, P .
SMART MATERIALS & STRUCTURES, 2001, 10 (03) :441-445
[10]   Vibration-based monitoring of civil infrastructure: Challenges and successes [J].
Brownjohn J.M.W. ;
de Stefano A. ;
Xu Y.-L. ;
Wenzel H. ;
Aktan A.E. .
Journal of Civil Structural Health Monitoring, 2011, 1 (3-4) :79-95