Accuracy of maxillary repositioning by computer-aided orthognathic surgery in patients with normal temporomandibular joints

被引:8
作者
Lin, Xiaozhen [1 ,2 ]
Li, Biao [1 ]
Wang, Xudong [1 ]
Shen, Steve G. F. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Dept Oral & Craniomaxillofacial Sci, Peoples Hosp 9,Shanghai Key Lab Stomatol, 639 Zhizaoju Rd, Shanghai, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Inst Stomatol, Dept Oral & Maxillofacial Surg, 28 Fuxing Rd, Beijing, Peoples R China
基金
中国博士后科学基金;
关键词
Computer-aided orthognathic surgery; Accuracy; Maxillary repositioning; Superimposition; Three-dimensional measurement; Bland-Altman method; SURGICAL SIMULATION; BIMAXILLARY SURGERY; PREDICTABILITY; NAVIGATION; TEMPLATES; OSTEOTOMY; COMPLEX; GUIDES; MODEL;
D O I
10.1016/j.bjoms.2017.02.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Our aim was to assess the accuracy of computer-aided orthognathic surgery for maxillary repositioning in 15 patients with mandibular hyperplasia and normal temporomandibular joints (TMJ). We aligned preoperative and postoperative virtual skulls at the cranium using surface superimposition then recorded and calibrated three 3 -dimensional coordinates (maxillary dental landmarks U0, 6R, and 6L) on the skulls. Errors between these preoperative and postoperative landmarks were calculated and the largest error of every patient was chosen for assessment. Landmark errors ranged from 1.00 - 2.49 mm, and recording errors from -0.06 - 0.07 mm The superimposition error was mean (SD) 0.036 (0.002) mm The accuracy of the method is acceptable in patients with a normal TMJ. (C) 2017 Published by Elsevier Ltd on behalf of The British Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:504 / 509
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 2005, J PROSTHET DENT, V94, P10
[2]   A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser [J].
Baan, Frank ;
Liebregts, Jeroen ;
Xi, Tong ;
Schreurs, Ruud ;
de Koning, Martien ;
Berge, Stefaan ;
Maal, Thomas .
PLOS ONE, 2016, 11 (02)
[3]   CAD/CAM surface templates as an alternative to the intermediate wafer in orthognathic surgery [J].
Bai, Shizhu ;
Bo, Bin ;
Bi, Yunpeng ;
Wang, Bo ;
Zhao, Jinlong ;
Liu, Yanpu ;
Feng, Zhihong ;
Shang, Hongtao ;
Zhao, Yimin .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (05) :E1-E7
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Precision of maxillary repositioning during orthognathic surgery: A prospective study [J].
Bouchard, Carl ;
Landry, Pierre-Eric .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (05) :592-596
[6]  
Gateno Jaime, 2011, Semin Orthod, V17, P225
[7]   Predictability of maxillary repositioning during bimaxillary surgery: accuracy of a new technique [J].
Gil, J. N. ;
Claus, J. D. P. ;
Manfro, R. ;
Lima, S. M., Jr. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (04) :296-300
[8]   The predictability of maxillary repositioning in LeFort I orthognathic surgery [J].
Jacobson, R ;
Sarver, DM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (02) :142-154
[9]   Accuracy of maxillary positioning in bimaxillary surgery [J].
Kretschmer, W. B. ;
Zoder, W. ;
Baciut, G. ;
Bacuit, Mihaela ;
Wangerin, K. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2009, 47 (06) :446-449
[10]   A New Method of Surgical Navigation for Orthognathic Surgery: Optical Tracking Guided Free- Hand Repositioning of the Maxillomandibular Complex [J].
Li, Biao ;
Zhang, Lei ;
Sun, Hao ;
Shen, Steve G. F. ;
Wang, Xudong .