Scaling characteristics of heart rate time series before the onset of ventricular tachycardia

被引:21
作者
Baumert, Mathias [1 ]
Wessel, Niels
Schirdewan, Alexander
Voss, Andreas
Abbott, Derek
机构
[1] Univ Adelaide, Sch Elect & Elect Engn, Adelaide, SA 5005, Australia
[2] Univ Adelaide, Ctr Biomed Engn, Adelaide, SA 5005, Australia
[3] Univ Appl Sci Jena, Dept Med Engn, D-07745 Jena, Germany
[4] Univ Potsdam, Inst Phys, D-14415 Potsdam, Germany
[5] Charite, Fac Med, Franz Volhard Clin, Helios Klinikum Berlin, D-13125 Berlin, Germany
基金
澳大利亚研究理事会;
关键词
implantable cardioverter defibrillators; heart rate variability; fractal dimension; detrended fluctuation analysis; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; RATE-VARIABILITY; BLOOD-PRESSURE; NONLINEAR DYNAMICS; ARRHYTHMIC EVENTS; FRACTAL DIMENSION; SYMBOLIC DYNAMICS; SHORT-TERM; FIBRILLATION; PATTERNS;
D O I
10.1007/s10439-006-9220-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ventricular tachycardia (VT) provokes sudden cardiac death (SCD), which is a major cause of mortality in developed countries. Implantable cardioverter-defibrillators (ICDs) are an efficient therapy for SCD prevention. In this study we analyze heart rate variability (HRV) in data stored by ICDs. In 29 patients exhibiting VT episodes, the last 1000 normal beat-to-beat intervals are analyzed and compared to an individually acquired control time series (CON). HRV analysis is performed with standard parameters of time and frequency domain as suggested by the HRV Task Force. For scaling analyses of heart rate time series, the fractal dimension is analysed, applying Higuchi's algorithm (HFD). Furthermore, detrended fluctuation analysis (DFA) is performed. None of the standard HRV parameters shows significant differences between CON and VT. Before the onset of VT, the scaling characteristics by means of HFD and DFA are significantly changed. In conclusion, scaling analysis reveals changes in autonomic heart rate modulation preceding VT.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 35 条
[1]   Forecasting of life threatening arrhythmias using the compression entropy of heart rate [J].
Baumert, M ;
Baier, V ;
Haueisen, J ;
Wessel, N ;
Meyerfeldt, U ;
Schirdewan, A ;
Voss, A .
METHODS OF INFORMATION IN MEDICINE, 2004, 43 (02) :202-206
[2]   Long-term correlations and fractal dimension of beat-to-beat blood pressure dynamics [J].
Baumert, M ;
Baier, V ;
Voss, A .
FLUCTUATION AND NOISE LETTERS, 2005, 5 (04) :L549-L555
[3]   Short- and long-term joint symbolic dynamics of heart rate and blood pressure in dilated cardiomyopathy [J].
Baumert, M ;
Baier, V ;
Truebner, S ;
Schirdewan, A ;
Voss, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (12) :2112-2115
[4]   Scaling graphs of heart rate time series in athletes demonstrating the VLF, LF and HF regions [J].
Baumert, Mathias ;
Brechtel, Lars M. ;
Lock, Juergen ;
Voss, Andreas ;
Abbott, Derek .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (09) :N35-N39
[5]  
Camm AJ, 1996, EUR HEART J, V17, P354
[6]  
CESAR A, 2002, ACC CURRENT J REV, P77
[7]   Temporal and geographical trends in indications for implantation of cardiac defibrillators in Europe 1993-1998 [J].
Copie, X ;
Piot, O ;
Said, MA ;
Lavergne, T ;
Ollitrault, J ;
Guize, L ;
Le Heuzey, JY .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06) :979-984
[8]   Electrogram width parameter analysis in implantable cardioverter defibrillators: Influence of body position and electrode configuration [J].
Favale, S ;
Nacci, F ;
Galati, A ;
Accogli, M ;
De Giorgi, V ;
Greco, MR ;
Nastasi, M ;
Pierfelice, O ;
Rossi, S ;
Gargaro, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1732-1738
[9]   Value of heart rate variability parameters for prediction of serious arrhythmic events in patients with malignant ventricular arrhythmias [J].
Filipecki, A ;
TruszGluza, M ;
Szydlo, K ;
Giec, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1852-1856
[10]   Management of malignant ventricular arrhythmias and cardiac arrest [J].
Fogel, RI ;
Prystowsky, EN .
CRITICAL CARE MEDICINE, 2000, 28 (10) :N165-N169