Policy of consultant oral and maxillofacial surgeons towards removal of miniplate components after jaw fracture fixation: pilot study

被引:46
作者
Matthew, IR [1 ]
Frame, JW [1 ]
机构
[1] Univ Birmingham, Sch Dent, Dept Oral Surg, Birmingham B4 6NN, W Midlands, England
关键词
D O I
10.1054/bjom.1997.0084
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A pilot study was undertaken to find out the policy of the 23 consultant oral and maxillofacial surgeons in the West Midlands towards removal of miniplates after jaw fractures had healed, All 23 replied, Two consultants did not use miniplates; the other 21 respondents used titanium systems, and two also used a stainless steel system, None of the 21 respondents routinely removed all miniplates. The estimated total of miniplates removed after the fracture had healed ranged between 5% and 40% (mode 5%), The main indications for removal were wound infection or dehiscence, before construction of a prosthesis, patients' concern about permanent retention of an implant, and thermal conductivity, We conclude that miniplates and screws are removed mainly to treat symptoms caused by the implants.
引用
收藏
页码:110 / 112
页数:3
相关论文
共 18 条
  • [1] Removal of asymptomatic bone plates used for orthognathic surgery and facial fractures
    Alpert, B
    Seligson, D
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (05) : 618 - 621
  • [2] ALSAFFAR N, 1994, BRIT J RHEUMATOL, V33, P309
  • [3] Bannon B.P., 1983, TITANIUM ALLOYS SURG, P7, DOI DOI 10.1520/STP28931S
  • [4] COMMERCIALLY PURE TITANIUM STEINHAUSER PLATE SCREW SYSTEM FOR MAXILLOFACIAL SURGERY
    BREME, J
    STEINHAUSER, E
    PAULUS, G
    [J]. BIOMATERIALS, 1988, 9 (04) : 310 - 313
  • [5] THE FATE OF MINIPLATES IN FACIAL TRAUMA AND ORTHOGNATHIC SURGERY - A RETROSPECTIVE STUDY
    BROWN, JS
    TROTTER, M
    CLIFFE, J
    WARDBOOTH, RP
    WILLIAMS, ED
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1989, 27 (04) : 306 - 315
  • [6] SMALL PLATE OSTEOSYNTHESIS OF MANDIBULAR FRACTURES
    CAWOOD, JI
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1985, 23 (02) : 77 - 91
  • [7] Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures
    Haug, RH
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (05) : 611 - 617
  • [8] RIGID INTERNAL-FIXATION OF MANDIBULAR FRACTURES - AN ANALYSIS OF 270 FRACTURES TREATED USING THE AO ASIF METHOD
    IIZUKA, T
    LINDQVIST, C
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 21 (02) : 65 - 69
  • [9] Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures
    Katou, F
    Andoh, N
    Motegi, K
    Nagura, H
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1996, 24 (03): : 155 - 162
  • [10] SENSITIVITY TO TITANIUM - A CAUSE OF IMPLANT FAILURE
    LALOR, PA
    REVELL, PA
    GRAY, AB
    WRIGHT, S
    RAILTON, GT
    FREEMAN, MAR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01): : 25 - 28