Conductive Adhesive Film Expands the Utility of Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging

被引:18
作者
Saigusa, Daisuke [1 ,2 ,3 ]
Saito, Ritsumi [1 ,2 ]
Kawamoto, Komei [4 ]
Uruno, Akira [1 ,2 ]
Kano, Kuniyuki [2 ,5 ]
Aoki, Junken [2 ,5 ]
Yamamoto, Masayuki [1 ,2 ]
Kawamoto, Tadafumi [4 ]
机构
[1] Tohoku Univ, Tohoku Med Megabank Org, Dept Integrat Genom, Aoba Ku, 2-1 Seiryo Machi, Sendai, Miyagi 9808573, Japan
[2] Tohoku Univ, Sch Med, Med Biochem, Aoba Ku, 2-1 Seiryo Machi, Sendai, Miyagi 9808575, Japan
[3] Japan Agcy Med Res & Dev AMED, LEAP, Chiyoda Ku, 1-7-1 Otemachi, Tokyo, Japan
[4] Tsurumi Univ, Sch Dent Med, Tsurumi Ku, 2-1-3 Tsurumi, Yokohama, Kanagawa 2308501, Japan
[5] Tohoku Univ, Grad Sch Pharmaceut Sci, Lab Mol & Cellular Biochem, Aoba Ku, 6-3 Aoba, Sendai, Miyagi 9808578, Japan
关键词
FROZEN-SECTIONS; HARD TISSUES; MOUSE-BRAIN; IDENTIFICATION; PHOSPHOLIPIDS; VISUALIZATION;
D O I
10.1021/acs.analchem.9b01159
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) technique is a promising approach for detecting the distribution of small molecules in a section of biological tissue. However, when a cryosection is created from fragile, hard, or whole-body samples, obtaining a high-quality section that maintains the distribution of the various components has been difficult. Since adhesive films have the potential to obtain high-quality cryosections, we attempted to utilize a conductive adhesive film for MALDI-MSI. To this end, cryosections of the whole body of a 9-day-old mouse were directly prepared on indium tin oxide (ITO) glass slides, nonconductive adhesive films, or conductive adhesive films, and the signal intensities from each section were measured by MALDI-MSI. We measured the differences in the ion intensity among these three slides/films by means of multivariate analyses and found that both the nonconductive and conductive adhesive films gave rise to high-quality sections in comparison with the ITO glass slide. The conductive adhesive film gave higher signals that were comparable to those of the ITO glass slide in comparison with the nonconductive adhesive film. We divided the frozen sections into two groups, a freeze-dried group and a thawed group, to examine the freeze thaw effect on the signals of representative compounds of amino acids, cholesterol, and phosphatidylcholines. The freeze-dried samples were found to be useful for the analysis. These results indicate that the sections made with the conductive adhesive film under a freeze-dried condition can expand the utility of the MALDI-MSI analysis.
引用
收藏
页码:8979 / 8986
页数:8
相关论文
共 45 条
  • [1] Mass spectrometry imaging for plant biology: a review
    Boughton, Berin A.
    Thinagaran, Dinaiz
    Sarabia, Daniel
    Bacic, Antony
    Roessner, Ute
    [J]. PHYTOCHEMISTRY REVIEWS, 2016, 15 (03) : 445 - 488
  • [2] Castellino S, 2011, BIOANALYSIS, V3, P2427, DOI [10.4155/bio.11.232, 10.4155/BIO.11.232]
  • [3] MALDI (matrix assisted laser desorption ionization) Imaging Mass Spectrometry (IMS) of skin: Aspects of sample preparation
    de Macedo, Cristiana Santos
    Anderson, David M.
    Schey, Kevin L.
    [J]. TALANTA, 2017, 174 : 325 - 335
  • [4] Assessing the Potential of Metal-Assisted Imaging Mass Spectrometry in Cancer Research
    Dufresne, M.
    Patterson, N. H.
    Lauzon, N.
    Chaurand, P.
    [J]. APPLICATIONS OF MASS SPECTROMETRY IMAGING TO CANCER, 2017, 134 : 67 - 84
  • [5] Fujino Yoko, 2016, Bone Rep, V5, P280, DOI 10.1016/j.bonr.2016.09.004
  • [6] MALDI Mass Spectrometric Imaging of Lipids in Rat Brain Injury Models
    Hankin, Joseph A.
    Farias, Santiago E.
    Barkley, Robert M.
    Heidenreich, Kim
    Frey, Lauren C.
    Hamazaki, Kei
    Kim, Hee-Yong
    Murphy, Robert C.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (06) : 1014 - 1021
  • [7] Hartler J, 2017, NAT METHODS, V14, P1171, DOI [10.1038/NMETH.4470, 10.1038/nmeth.4470]
  • [8] Matrix-assisted laser desorption/ionization imaging mass spectrometry revealed traces of dental problem associated with dental structure
    Hirano, Hirokazu
    Masaki, Noritaka
    Hayasaka, Takahiro
    Watanabe, Yoshiko
    Masumoto, Kazuma
    Nagata, Tetsuji
    Katou, Fuminori
    Setou, Mitsutoshi
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (05) : 1355 - 1363
  • [9] Global changes of phospholipids identified by MALDI imaging mass spectrometry in a mouse model of Alzheimer's disease
    Hong, Ji Hye
    Kang, Jeong Won
    Kim, Dong Kyu
    Baik, Sung Hoon
    Kim, Kyung Ho
    Shanta, Selina Rahman
    Jung, Jae Hun
    Mook-Jung, Inhee
    Kim, Kwang Pyo
    [J]. JOURNAL OF LIPID RESEARCH, 2016, 57 (01) : 36 - 45
  • [10] Direct profiling of lipid distribution in brain tissue using MALDI-TOFMS
    Jackson, SN
    Wang, HYJ
    Woods, AS
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (14) : 4523 - 4527