Radiation exposure with spiral CT of the paranasal sinuses

被引:23
作者
Dammann, F
Momino-Traserra, E
Remy, C
Pereira, PL
Baumann, I
Koitschev, A
Claussen, CD
机构
[1] Univ Tubingen, Radiol Klin, Abt Radiol Diagnost, D-72076 Tubingen, Germany
[2] Univ Tubingen Klin, Klin Hals Nasen Ohrenheilkunde, Tubingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 03期
关键词
computed tomography; spiral CT; radiation exposure; dose reduction; paranasal sinuses;
D O I
10.1055/s-2000-118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Determination of the radiation doses in spiral CT of the paranasal sinuses using a variety of mAs values and scan protocols. Material and methods: CT examinations of the paranasal sinuses were performed using an Alderson-Rando phantom. Radiation dose was determined by LiF-TLD at the level of high risk organs in the head and neck region for combinations of different scan parameters (2/3, 3/3, 3/4 mm) and decreasing charges (200, 150, 100, 50, 25 mAs) on a spiral CT. Additional measurements were performed on three other CT scanners using the 2/3 mm protocol at 50 mAs, and a single slice technique (5/5 mm) on one scanner. Results: The lowest dose values found were 1.88 mGy for the eye Tenses, 1.35 mGy for the parotid gland, 0.03 mGy for the thyroid gland and 0.1 mGy for the medulla oblongata using 2 mm collimation and 3 mm table feed at 25 mAs. Maximal dose values resulted using the 3/3 mm protocol at 200 mAs (31.00 mGy for the eye lense, 0.65 mGy for the thyroid gland). There were no significant differences found between the different CT scanners. Conclusions: Using up-to-date CT scanners, radiation exposure may be reduced by a factor of 15-20 compared to that of conventional CT technique. Thus, the exposure of the eye lens comes to only a thousandth of the value supposedly inducing a cataract, as published by the ICRP.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 27 条
[1]  
[Anonymous], 1991, ICRP PUBL, V60
[2]  
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[3]  
Beus J, 1995, Aktuelle Radiol, V5, P189
[4]  
BUCHGEISTER M, 1998, MED PHYSIK TAGUNGSBA, V98, P253
[5]   Dosage measurement in spiral CT examinations in the head and neck region [J].
Cohnen, M ;
Cohnen, B ;
Ewen, K ;
Teubert, G ;
Modder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (05) :474-479
[6]   AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY [J].
CONWAY, BJ ;
MCCROHAN, JL ;
ANTONSEN, RG ;
RUETER, FG ;
SLAYTON, RJ ;
SULEIMAN, OH .
RADIOLOGY, 1992, 184 (01) :135-140
[7]  
DAMMANN F, 1999, ROFO FORTSCHR RONTG, V170, pS36
[8]   Low-dose computed tomography of the thorax. Experimental and clinical investigations [J].
Diederich, S ;
Lenzen, H ;
Puskas, Z ;
Koch, AT ;
Yelbuz, TM ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGE, 1996, 36 (06) :475-482
[9]   Low-dose spiral-CT [J].
Diederichs, CG ;
Bruhn, H ;
Funke, M ;
Grabbe, E .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (03) :183-188
[10]   LOW-DOSE CT AND INFLAMMATORY DISEASE OF THE PARANASAL SINUSES [J].
DUVOISIN, B ;
LANDRY, M ;
CHAPUIS, L ;
KRAYENBUHL, M ;
SCHNYDER, P .
NEURORADIOLOGY, 1991, 33 (05) :403-406