Dosimetric verification of MammoSite treatment plans using Monte Carlo simulations and measurements with a 2D ionization chamber array

被引:0
作者
Budde, Moritz [1 ]
Adamietz, Irenaeus A. [1 ]
Sommer, Holger [2 ]
Hermani, Horst [1 ]
机构
[1] Marien Hosp Herne, Klin Strahlentherapie & Radioonkol, D-44625 Herne, Germany
[2] Tech Univ Dortmund, Expt Phys 5, D-44221 Dortmund, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2018年 / 28卷 / 02期
关键词
Brachytherapy; HDR; MammoSite; Dosimetry; Monte Carlo; DOSE-RATE BRACHYTHERAPY; STAGE BREAST-CANCER; DETECTOR; PHANTOM;
D O I
10.1016/j.zemedi.2017.09.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The surgical removal of a breast tumour is often followed by postoperative irradiation of the surrounding tissue with a radioactive source (brachytherapy). When performing the MammoSite procedure, a spherical silicone balloon is inserted and filled with a NaCl solution. In a period of about five days in several sessions an iridium-192 source with high activity travels through a catheter into the balloon (afterloading) to irradiate the tumour cells remaining in the cavity. In this study, dose distributions of a MammoSite applicator are investigated based on measurements with a 2D detector array, Monte Carlo simulations and calculations with BrachyVision. The focus is set on the 2D detector array and its possible application in the verification process in 3D brachytherapy treatment planning. The measured dose distributions conform well to the doses of BrachyVision with deviations of less than 5% within the clinically relevant field range. The deviations of the measured and calculated distributions from the simulation results are below 3%. The 2D detector array allows a new verification method for MammoSite treatment plans with sufficient accuracy. Future verifications can be performed without additional Monte Carlo simulations.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 17 条
  • [1] Technical note:: Monte-Carlo dosimetry of the HDR 12i and plus 192Ir sources
    Ballester, F
    Puchades, V
    Lluch, JL
    Serrano-Andrés, MA
    Limami, Y
    Pérez-Calatayud, J
    Casal, E
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2586 - 2591
  • [2] Five-year results: the initial clinical trial of mammosite balloon brachytherapy for partial breast irradiation in early-stage breast cancer
    Benitez, Pamela R.
    Keisch, Martin E.
    Vicini, Frank
    Stolier, Alan
    Scroggins, Troy
    Walker, Alonzo
    White, Julia
    Hedberg, Peter
    Hebert, Mary
    Arthur, Doug
    Zannis, Vic
    Quiet, Coral
    Streeter, Oscar
    Silverstein, Mel
    [J]. AMERICAN JOURNAL OF SURGERY, 2007, 194 (04) : 456 - 462
  • [3] Dose perturbations due to contrast medium and air in MammoSite® treatment:: An experimental and Monte Carlo study
    Cheng, CW
    Mitra, R
    Li, XA
    Das, IJ
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2279 - 2287
  • [4] Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    Chetty, Indrin J.
    Curran, Bruce
    Cygler, Joanna E.
    DeMarco, John J.
    Ezzell, Gary
    Faddegon, Bruce A.
    Kawrakow, Iwan
    Keall, Paul J.
    Liu, Helen
    Ma, C. -M. Charlie
    Rogers, D. W. O.
    Seuntjens, Jan
    Sheikh-Bagheri, Daryoush
    Siebers, Jeffrey V.
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4818 - 4853
  • [5] Thermoluminescence dosimetry for in-vivo verification of high dose rate brachytherapy for prostate cancer
    Das, R.
    Toye, W.
    Kron, T.
    Williams, S.
    Duchesne, G.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (03) : 178 - 184
  • [6] Huang Y Jessica, 2009, J Appl Clin Med Phys, V11, P2932
  • [7] Initial clinical experience with the MammoSite breast brachytherapy applicator in women with early-stage breast cancer treated with breast-conserving therapy
    Keisch, M
    Vicini, F
    Kuske, RR
    Hebert, M
    White, J
    Quiet, C
    Arthur, D
    Scroggins, T
    Streeter, O
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (02): : 289 - 293
  • [8] In vivo dosimeters for HDR brachytherapy:: A comparison of a diamond detector, MOSFET, TLD, and scintillation detector
    Lambert, Jamil
    Nakano, Tatsuya
    Law, Sue
    Elsey, Justin
    McKenzie, David R.
    Suchowerska, Natalka
    [J]. MEDICAL PHYSICS, 2007, 34 (05) : 1759 - 1765
  • [9] Lewis HW, 1950, PHYS REV, V78
  • [10] Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques
    Palmer, Antony
    Bradley, David
    Nisbet, Andrew
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2012, 4 (02) : 81 - 91