Experimental Discussions on a Shaft End-to-End Voltage Appearing in an Inverter-Driven Motor

被引:57
作者
Shami, Umar Tabrez [1 ]
Akagi, Hirofumi [1 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 1528552, Japan
关键词
Bearing current; electromagnetic interference (EMI); ground leakage current; motor drives; pulsewidth modulation (PWM) inverters; shaft voltage; COMMON-MODE VOLTAGE; PASSIVE EMI FILTER; FREQUENCY LEAKAGE CURRENT; BEARING CURRENTS; PWM INVERTER; INDUCTION-MOTOR; HEAT SINK; REDUCTION; ATTENUATION; SYSTEMS;
D O I
10.1109/TPEL.2009.2013625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper addresses shaft end-to-end and shaft-to-frame voltages that appear in the 400-V, 15-kW induction motor driven by a voltage-source pulsewidth modulation (PWM) inverter. A shaft-to-frame voltage can be observed at either shaft end with respect to the grounded motor frame. A shaft end-to-end voltage can be observed as a voltage difference between the shaft-to-frame voltage at the drive end (DE) and that at the nondrive end (NDE). Experimental waveforms lead to the following interesting observations: motor internal coupling and parasitic capacitance, along with the high-frequency common-mode voltage generated by the PWM inverter, cause a shaft-to-frame voltage with a peak of 8 V at both DE and NDE. When the shaft-to-frame voltage at either DE or NDE exceeds a dielectric breakdown voltage of thin bearing lubricating grease films, a shaft end-to-end voltage with a peak of 2 V and a width of 30 ns occurs along the motor shaft. This paper makes experimental discussions on the shaft end-to-end voltage generation. Installing a differential-mode filter and/or a common-mode filter on the motor drive system gives a hint on the mechanisms of the occurrence of the shaft end-to-end voltage.
引用
收藏
页码:1532 / 1540
页数:9
相关论文
共 36 条
[1]   A passive EMI filter for preventing high-frequency leakage current from flowing through the grounded inverter heat sink of an adjustable-speed motor drive system [J].
Akagi, H ;
Doumoto, T .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1215-1223
[2]  
Akagi H, 2004, IEEE T IND APPL, V40, P1162, DOI [10.1109/TIA.2004.830748, 10.1109/tia.2004.830748]
[3]   Design and performance of a passive EMI filter for use with a voltage-source PWM inverter having sinusoidal output voltage and zero common-mode voltage [J].
Akagi, H ;
Hasegawa, H ;
Doumoto, T .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (04) :1069-1076
[4]   Attenuation of conducted EMI emissions from an inverter-driven motor [J].
Akagi, Hirofumi ;
Shimizu, Takayuki .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) :282-290
[5]   A specific filter for eliminating high-frequency leakage current from the grounded heat sink in a motor drive with an active front end [J].
Akagi, Hirofumi ;
Oe, Takehiko .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (02) :763-770
[6]   A passive EMI filter for eliminating both bearing current and ground leakage current from an inverter-driven motor [J].
Akagi, Hirofumi ;
Tamura, Shunsuke .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (05) :1459-1469
[7]   Experimental comparison of motor bearing currents with PWM hard- and soft-switched voltage-source inverters [J].
Bhattacharya, S ;
Resta, L ;
Divan, DM ;
Novotny, DW .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (03) :552-562
[8]   Bearing currents and their relationship to PWM drives [J].
Busse, D ;
Erdman, J ;
Kerkman, RJ ;
Schlegel, D ;
Skibinski, G .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) :243-252
[9]  
Busse D., 1997, IEEE Industry Applications Magazine, V3, P21, DOI 10.1109/2943.628116
[10]   Reduction of common-mode currents in PWM inverter motor drives [J].
Cacciato, M ;
Consoli, A ;
Scarcella, G ;
Testa, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (02) :469-476