Synchronized Pulsatile Speed Control of Turbodynamic Left Ventricular Assist Devices: Review and Prospects

被引:29
作者
Amacher, Raffael [1 ]
Ochsner, Gregor [1 ]
Daners, Marianne Schmid [1 ]
机构
[1] ETH, Dept Mech & Proc Engn, Inst Dynam Syst & Control, CH-8092 Zurich, Switzerland
关键词
ROTARY BLOOD PUMP; MYOCARDIAL OXYGEN-CONSUMPTION; TOTAL ARTIFICIAL-HEART; CIRCULATORY SUPPORT; CENTRIFUGAL PUMP; HEMOLYSIS TEST; IMPELLER PUMP; PULSE; NONPULSATILE; MODULATION;
D O I
10.1111/aor.12253
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Turbodynamic blood pumps are used clinically as ventricular assist devices (VADs). They are mostly operated at a constant rotational speed, which results in a reduced pulsatility. Previous research has analyzed pulsing pump speeds (speed modulation) to alter the interaction between the cardiovascular system and the blood pump. In those studies, sine- or square-wave speed profiles that were synchronized to the natural cardiac cycle were analyzed in silico, in vitro and in vivo. The definitions of these profiles with respect to both timing and speed levels vary among different research groups. The current paper provides a definition of the timing of these speed profiles such that the resulting hemodynamic effects become comparable. The results published in the literature are summarized and compared using this definition. Further, applied to a turbodynamic VAD, a series of measurements is conducted on a hybrid mock circulation using a constant speed as well as different types of square-wave speed profiles and a sine-wave speed profile. When a consistent definition of the timing of the speed profiles is used, the hemodynamic effects observed in previous work are in agreement with the measurement data obtained for the current paper. These findings allow the conclusion that the speed modulation of turbodynamic VADs represents a consistent tool to systematically change the ventricular load and the pulsatility in the arterial tree. The timing that yields the minimal left ventricular load also yields the minimal arterial pulse pressure.
引用
收藏
页码:867 / U99
页数:9
相关论文
共 58 条
[1]   Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device [J].
Amacher, Raffael ;
Weber, Alberto ;
Brinks, Henriette ;
Axiak, Shannon ;
Ferreira, Antonio ;
Guzzella, Lino ;
Carrel, Thierry ;
Antaki, James ;
Vandenberghe, Stijn .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (03) :710-717
[2]   A Robust Reference Signal Generator for Synchronized Ventricular Assist Devices [J].
Amacher, Raffael ;
Ochsner, Gregor ;
Ferreira, Antonio ;
Vandenberghe, Stijn ;
Daners, Marianne Schmid .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (08) :2174-2183
[3]   Electrocardiogram-Synchronized Rotational Speed Change Mode in Rotary Pumps Could Improve Pulsatility [J].
Ando, Masahiko ;
Nishimura, Takashi ;
Takewa, Yoshiaki ;
Yamazaki, Kenji ;
Kyo, Shunei ;
Ono, Minoru ;
Tsukiya, Tomonori ;
Mizuno, Toshihide ;
Taenaka, Yoshiyuki ;
Tatsumi, Eisuke .
ARTIFICIAL ORGANS, 2011, 35 (10) :941-947
[4]   A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion [J].
Ando, Masahiko ;
Takewa, Yoshiaki ;
Nishimura, Takashi ;
Yamazaki, Kenji ;
Kyo, Shunei ;
Ono, Minoru ;
Tsukiya, Tomonori ;
Mizuno, Toshihide ;
Taenaka, Yoshiyuki ;
Tatsumi, Eisuke .
JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (03) :185-191
[5]  
Antaki JF, 2003, 42ND IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-6, PROCEEDINGS, P4084
[6]   A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump [J].
Arvand, A ;
Hormes, M ;
Reul, H .
ARTIFICIAL ORGANS, 2005, 29 (07) :531-540
[7]  
Banchs JE, 2006, J AM SOC ECHOCARDIOG, V19
[8]   Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings [J].
Bearnson, GB ;
Olsen, DB ;
Khanwilkar, PS ;
Long, JW ;
Allaire, PE ;
Maslen, EH .
ASAIO JOURNAL, 1996, 42 (05) :M620-M624
[9]   Towards Non-thrombogenic Performance of Blood Recirculating Devices [J].
Bluestein, D. ;
Chandran, K. B. ;
Manning, K. B. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) :1236-1256
[10]   In vivo assessment of a rotary left ventricular assist device-induced artificial pulse in the proximal and distal aorta [J].
Bourque, Kevin ;
Dague, Charles ;
Farrar, David ;
Harms, Kelly ;
Tamez, Dan ;
Cohn, William ;
Tuzun, Egemeun ;
Poirier, Victor ;
Frazier, O. Howard .
ARTIFICIAL ORGANS, 2006, 30 (08) :638-642