Whole-Heart Chemical Shift Encoded Water-Fat MRI

被引:8
作者
Taviani, Valentina [1 ]
Hernando, Diego [1 ]
Francois, Christopher J. [1 ]
Shimakawa, Ann [2 ]
Vigen, Karl K. [1 ]
Nagle, Scott K. [1 ,3 ,4 ]
Schiebler, Mark L. [1 ]
Grist, Thomas M. [1 ,3 ,5 ]
Reeder, Scott B. [1 ,3 ,5 ,6 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Pediat, Madison, WI USA
[5] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin, Dept Med, Madison, WI USA
关键词
chemical shift encoding; water; fat; free-breathing; 3D; CARDIOVASCULAR MAGNETIC-RESONANCE; LOCALIZED PROTON SPECTROSCOPY; STATE FREE PRECESSION; MULTIECHO DIXON FAT; PERICARDIAL DISEASES; ATRIAL-FIBRILLATION; MYOCARDIAL FAT; CARDIAC IRON; SEPARATION; RECONSTRUCTION;
D O I
10.1002/mrm.24982
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate a free-breathing chemicalshift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). Methods: We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluated its performance at 3T in healthy volunteers (N = 6) and patients (N = 20). CSE-SPGR, 3D SPGR, and 3D balanced-SSFP with chemical fat saturation were compared in six healthy subjects with images evaluated for overall image quality, level of residual artifacts, and quality of fat suppression. A similar scoring system was used for the patient datasets. Results: Images of diagnostic quality were acquired in all but one subject. CSE-SPGR performed similarly to SPGR with fat saturation, although it provided a more uniform fat suppression over the whole field of view. Balanced-SSFP performed worse than SPGR-based methods. In patients, CSE-SPGR produced excellent fat suppression near metal. Overall image quality was either good (7/20) or excellent (12/20) in all but one patient. There were significant artifacts in 5/20 clinical cases. Conclusion: CSE-SPGR is a promising technique for whole-heart water-fat imaging during free-breathing. The robust fat suppression in the water-only image could improve assessment of complex morphology at 3T and in the presence of off-resonance, with additional information contained in the fat-only image. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 50 条
[41]   Free-running 4D whole-heart self-navigated golden angle MRI: Initial results [J].
Coppo, Simone ;
Piccini, Davide ;
Bonanno, Gabriele ;
Chaptinel, Jerome ;
Vincenti, Gabriella ;
Feliciano, Helene ;
van Heeswijk, Ruud B. ;
Schwitter, Juerg ;
Stuber, Matthias .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) :1306-1316
[42]   Ultrafast water-fat separation using deep learning-based single-shot MRI [J].
Chen, Xinran ;
Wang, Wei ;
Huang, Jianpan ;
Wu, Jian ;
Chen, Lin ;
Cai, Congbo ;
Cai, Shuhui ;
Chen, Zhong .
MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (06) :2811-2825
[43]   Comparison between fast-interrupted steady-state (FISS) and rapid water-excitation pulses for fat signal suppression in free-running whole-heart MRI at 1.5 T [J].
Safarkhanlo, Yasaman ;
Yerly, Jerome ;
Falcao, Mariana B. L. ;
Mackowiak, Adele L. C. ;
Piccini, Davide ;
Stuber, Matthias ;
Jung, Bernd ;
Grani, Christoph ;
Bastiaansen, Jessica A. M. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2025,
[44]   Chemical shift-encoded MRI for assessment of bone marrow adipose tissue fat composition: Pilot study in premenopausal versus postmenopausal women [J].
Martel, Dimitri ;
Leporq, Benjamin ;
Bruno, Mary ;
Regatte, Ravinder R. ;
Honig, Stephen ;
Chang, Gregory .
MAGNETIC RESONANCE IMAGING, 2018, 53 :148-155
[45]   3D Dixon water-fat LGE imaging with image navigator and compressed sensing in cardiac MRI [J].
Zeilinger, Martin Georg ;
Wiesmueller, Marco ;
Forman, Christoph ;
Schmidt, Michaela ;
Munoz, Camila ;
Piccini, Davide ;
Kunze, Karl-Philipp ;
Neji, Radhouene ;
Botnar, Rene Michael ;
Prieto, Claudia ;
Uder, Michael ;
May, Matthias ;
Wuest, Wolfgang .
EUROPEAN RADIOLOGY, 2021, 31 (06) :3951-3961
[46]   Retrospective Camera-Based Respiratory Gating in Clinical Whole-Heart 4D Flow MRI [J].
Gottwald, Lukas M. ;
Blanken, Carmen P. S. ;
Tourais, Joao ;
Smink, Jouke ;
Planken, R. Nils ;
Boekholdt, S. Matthijs ;
Meijboom, Lilian J. ;
Coolen, Bram F. ;
Strijkers, Gustav J. ;
Nederveen, Aart J. ;
van Ooij, Pim .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (02) :440-451
[47]   Flow-Induced Signal Misallocation Artifacts in Two-Point Fat-Water Chemical Shift MRI [J].
Rahimi, Mahdi Salmani ;
Holmes, James H. ;
Wang, Kang ;
Reeder, Scott B. ;
Korosec, Frank R. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) :1926-1931
[48]   Respiratory self-navigation for whole-heart bright-blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood pool [J].
Piccini, Davide ;
Littmann, Arne ;
Nielles-Vallespin, Sonia ;
Zenge, Michael O. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) :571-579
[49]   Use of chemical shift encoded magnetic resonance imaging (CSE-MRI) for high resolution fat-suppressed imaging of the brachial and lumbosacral plexuses [J].
Grayev, Allison ;
Reeder, Scott ;
Hanna, Amgad .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) :1199-1207
[50]   Cardio-respiratory motion-corrected 3D cardiac water-fat MRI using model-based image reconstruction [J].
Mayer, Johannes ;
Blaszczyk, Edyta ;
Cipriani, Alberto ;
Ferrazzi, Giulio ;
Schulz-Menger, Jeanette ;
Schaeffter, Tobias ;
Kolbitsch, Christoph .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) :1561-1574