Innovative computerized non-invasive intracranial pressure measurement technology and its clinical validation

被引:0
作者
Krakauskaite, Solventa [1 ]
Petkus, Vytautas [1 ]
Zakelis, Rolandas [1 ]
Bartusis, Laimonas [1 ]
Chomskis, Romanas [1 ]
Ragauskas, Arminas [1 ]
机构
[1] KaunasUniv Technol, Telemat Sci Ctr, Kaunas, Lithuania
来源
2014 IEEE 27TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS) | 2014年
关键词
intracranial pressure; non-invasive technology; clinical validation; AUTOREGULATION; HUMANS;
D O I
10.1109/CBMS.2014.40
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An innovative non-invasive absolute intracranial pressure (aICP) measurement method has been validated by multicenter comparative clinical studies. The method is based on two-depth transcranial Doppler technology and employs intracranial and extracranial segments of the ophthalmic artery as a pressure sensor. The ophthalmic artery is used as a natural pair of scales which compares aICP with controlled pressure aPe which is externally applied to the orbit. In the case of scales balance, aICP=aPe. A two-depth transcranial Doppler device is used as a pressure balance indicator. The proposed method is the only non-invasive aICP measurement method which does not need patient-specific calibration.
引用
收藏
页码:451 / 454
页数:4
相关论文
共 9 条
  • [1] CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS
    AASLID, R
    LINDEGAARD, KF
    SORTEBERG, W
    NORNES, H
    [J]. STROKE, 1989, 20 (01) : 45 - 52
  • [2] Continuous assessment of the cerebral vasomotor reactivity in head injury
    Czosnyka, M
    Smielewski, P
    Kirkpatrick, P
    Laing, RJ
    Menon, D
    Pickard, JD
    [J]. NEUROSURGERY, 1997, 41 (01) : 11 - 17
  • [3] Faul MX., 2010, Centers for Disease Control and Prevention, National Center for Injury Prevention and Control
  • [4] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    [J]. ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204
  • [5] Assessment of cerebral pressure autoregulation in humans - a review of measurement methods
    Panerai, RB
    [J]. PHYSIOLOGICAL MEASUREMENT, 1998, 19 (03) : 305 - 338
  • [6] Clinical assessment of noninvasive intracranial pressure absolute value measurement method
    Ragauskas, A.
    Matijosaitis, V.
    Zakelis, R.
    Petrikonis, K.
    Rastenyte, D.
    Piper, I.
    Daubaris, G.
    [J]. NEUROLOGY, 2012, 78 (21) : 1684 - 1691
  • [7] Ragauskas A, 2013, US Patent, Patent No. [8,394,025, 8394025]
  • [8] Dynamic cerebral autoregulation is preserved in neurally mediated syncope
    Schondorf, R
    Stein, R
    Roberts, R
    Benoit, J
    Cupples, W
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (06) : 2493 - 2502
  • [9] Zakelis R., 2012, THESIS KAUNAS U TECH