Mueller matrix three-dimensional directional imaging of collagen fibers

被引:33
作者
Ellingsen, Pal Gunnar [1 ]
Aas, Lars Martin Sandvik [1 ]
Hagen, Vegard Stenhjem [1 ]
Kumar, Rajesh [1 ]
Lilledahl, Magnus Borstad [1 ]
Kildemo, Morten [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Phys, Fac Nat Sci & Technol, N-7034 Trondheim, Norway
关键词
Mueller matrix imaging; collagen; directional imaging; second-harmonic; POLARIZED-LIGHT; DECOMPOSITION; MEDIA;
D O I
10.1117/1.JBO.19.2.026002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for measuring three-dimensional (3-D) direction images of collagen fibers in biological tissue is presented. Images of the 3-D directions are derived from the measured transmission Mueller matrix images (MMIs), acquired at different incidence angles, by taking advantage of the form birefringence of the collagen fibers. The MMIs are decomposed using the recently developed differential decomposition, which is more suited to biological tissue samples than the common polar decomposition method. Validation of the 3-D direction images was performed by comparing them with images from second-harmonic generation microscopy. The comparison found a good agreement between the two methods. It is envisaged that 3-D directional imaging could become a useful tool for understanding the collagen framework for fibers smaller than the diffraction limit. (C) The Authors.
引用
收藏
页数:6
相关论文
共 27 条
[1]   Determination of small tilt angles of short GaSb nanopillars using UV-visible Mueller matrix ellipsometry [J].
Aas, L. M. S. ;
Kildemo, M. ;
Cohin, Y. ;
Sondergard, E. .
THIN SOLID FILMS, 2013, 541 :97-101
[2]   Optical properties of biaxial nanopatterned gold plasmonic nanowired grid polarizer [J].
Aas, Lars Martin Sandvik ;
Kildemo, Morten ;
Martella, Christian ;
Giordano, Maria Caterina ;
Chiappe, Daniele ;
de Mongeot, Francesco Buatier .
OPTICS EXPRESS, 2013, 21 (25) :30918-30931
[3]   Overdetermined broadband spectroscopic Mueller matrix polarimeter designed by genetic algorithms [J].
Aas, Lars Martin Sandvik ;
Ellingsen, Pal Gunnar ;
Fladmark, Bent Even ;
Letnes, Paul Anton ;
Kildemo, Morten .
OPTICS EXPRESS, 2013, 21 (07) :8753-8762
[4]   Near infra-red Mueller matrix imaging system and application to retardance imaging of strain [J].
Aas, Lars Martin Sandvik ;
Ellingsen, Pal Gunnar ;
Kildemo, Morten .
THIN SOLID FILMS, 2011, 519 (09) :2737-2741
[5]  
[Anonymous], 2007, TISSUE OPTICS LIGHT, DOI DOI 10.1117/3.684093
[6]   Mueller matrix imaging of human colon tissue for cancer diagnostics: how Monte Carlo modeling can help in the interpretation of experimental data [J].
Antonelli, Maria-Rosaria ;
Pierangelo, Angelo ;
Novikova, Tatiana ;
Validire, Pierre ;
Benali, Abdelali ;
Gayet, Brice ;
De Martino, Antonello .
OPTICS EXPRESS, 2010, 18 (10) :10200-10208
[7]  
Azzam R. M. A., 1977, Ellipsometry and Polarized Light
[8]   PROPAGATION OF PARTIALLY POLARIZED-LIGHT THROUGH ANISOTROPIC MEDIA WITH OR WITHOUT DEPOLARIZATION - DIFFERENTIAL 4X4 MATRIX CALCULUS [J].
AZZAM, RMA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (12) :1756-1767
[9]   Use of polar decomposition for the diagnosis of oral precancer [J].
Chung, Jungrae ;
Jung, Woonggyu ;
Hammer-Wilson, Marie J. ;
Wilder-Smith, Petra ;
Chen, Zhongping .
APPLIED OPTICS, 2007, 46 (15) :3038-3045
[10]  
CLOUDE SR, 1990, P SOC PHOTO-OPT INS, V1166, P177, DOI 10.1117/12.962889