Multiobjective Equivalent Static Wind Loads on Complex Tall Buildings Using Non-Gaussian Peak Factors

被引:13
|
作者
Lou, Wenjuan [1 ]
Zhang, Ligang [2 ]
Huang, M. F. [1 ]
Li, Q. S. [3 ]
机构
[1] Zhejiang Univ, Inst Struct Engn, Hangzhou 310058, Zhejiang, Peoples R China
[2] State Grid Zhejiang Elect Power Co, Econ Res Inst, Hangzhou 310058, Zhejiang, Peoples R China
[3] City Univ Hong Kong, Dept Civil & Architectural Engn, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Tall buildings; Three-dimensional; Equivalent static wind loads; Peak factor; Non-Gaussian; Wind effects; DISTRIBUTIONS;
D O I
10.1061/(ASCE)ST.1943-541X.0001277
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Equivalent static wind loads (ESWLs) play an important role in the wind-resistant design of tall buildings. Traditionally, ESWLs of a tall building are derived based on the equivalence of the top deflection or the base force along the principal direction, which is easy to identify for a regular tall building. For flexible tall buildings with simple or complex shapes, wind-induced dynamic responses are three-dimensional, which often complicates the application of the ESWLs. Based on the time-domain dynamic analysis method, a new scheme is developed in this paper to model multiobjective equivalent static wind loads (M-ESWLs) on complex tall buildings. The possible non-Gaussian properties of wind-induced response processes have been taken into account in M-ESWLs by using non-Gaussian peak factors. Furthermore, a joint action reduction factor is carefully defined to reflect the partial correlations among multiple component responses. Finally, the new scheme is applied to a practical 43-story tall building with irregular geometric shapes to illustrate the application and effectiveness of the new method. In this work it was assumed that wind speeds do not depend on direction. Future research should include complementing this work by accounting for the effects of wind speed directionality. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 43 条
  • [1] Non-Gaussian approach for equivalent static wind loads from wind tunnel measurements
    Kassir, Wafaa
    Soize, Christian
    Heck, Jean-Vivien
    De Oliveira, Fabrice
    WIND AND STRUCTURES, 2017, 25 (06) : 589 - 608
  • [2] Peak factors of non-Gaussian wind forces on a complex-shaped tall building
    Huang, Mingfeng
    Lou, Wenjuan
    Chan, Chun-Man
    Bao, Sheng
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2013, 22 (14) : 1105 - 1118
  • [3] Reduced Equivalent Static Wind Loads for Tall Buildings with Tuned Liquid Dampers
    Ross, A. S.
    El Damatty, A. A.
    El Ansary, A. M.
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 1218 - 1227
  • [4] Analysis on non-Gaussian features of fluctuating wind pressure on square tall buildings
    Han, Ning
    Gu, Ming
    Tongji Daxue Xuebao/Journal of Tongji University, 2012, 40 (07): : 971 - 976
  • [5] Peak factor estimation of non-Gaussian wind pressure on high-rise buildings
    Ma, Xingliang
    Xu, Fuyou
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (17)
  • [6] Non-Gaussian features and peak factors of fluctuating wind pressures on a complex curved roof
    Yang X.
    Zhou Q.
    Li M.
    Wang P.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (10): : 315 - 322
  • [7] Reconstruction of the envelope of non-Gaussian structural responses with principal static wind loads
    Blaise, Nicolas
    Canor, Thomas
    Denoel, Vincent
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 149 : 59 - 76
  • [8] Equivalent static wind loads vs. database-assisted design of tall buildings: An assessment
    Park, Sejun
    Simiu, Emil
    Yeo, DongHun
    ENGINEERING STRUCTURES, 2019, 186 : 553 - 563
  • [9] A review of approaches to generate equivalent static and synthetic wind loads on tall buildings for the preliminary stage of design
    Salehinejad, M. Mahdi
    Flay, Richard George James
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2021, 219
  • [10] Wind load effects and equivalent static wind loads of three-tower connected tall buildings based on wind tunnel tests
    Ke, Shitang
    Wang, Hao
    Ge, Yaojun
    STRUCTURAL ENGINEERING AND MECHANICS, 2016, 58 (06) : 967 - 988