An aptamer-based biosensor for sensitive thrombin detection

被引:88
|
作者
Yang, Hui [1 ]
Ji, Ji [1 ]
Liu, Yun [1 ]
Kong, Jilie [1 ]
Liu, Baohong [1 ]
机构
[1] Fudan Univ, Dept Chem, Inst Biomed Sci, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Aptamer; Quantum dots; Thrombin; Electrochemistry; Sensor; ELECTROCHEMICAL DETECTION; REAGENTLESS; LABELS; DNA; APTASENSOR; SELECTION; PROTEINS; SENSOR; SWITCH;
D O I
10.1016/j.elecom.2008.10.024
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A sensitive aptamer-based sandwich-type sensor is presented to detect human thrombin using quantum dots as electrochemical label. CdSe quantum dots were labeled to the secondary aptamer, which were determined by the square wave stripping voltammetric analysis after dissolution with nitric acid. The aptasensor has a lower detection limit at I pM, while the sample consumption is reduced to 5 mu l. The proposed approach shows high selectivity and minimizes the nonspecific adsorption, so that it was used for the detection of target protein in the human serum sample. Such an aptamer-based biosensor provides a promising strategy for screening biomarkers at ultratrace levels in the complex matrices. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 40
页数:3
相关论文
共 50 条
  • [1] DNA aptamer-based QDs electrochemiluminescence biosensor for the detection of thrombin
    Huang, Haiping
    Zhu, Jun-Jie
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) : 927 - 930
  • [2] Aptamer-Based Biosensor
    Zheng Jing
    He Pingang
    Fang Yuzhi
    PROGRESS IN CHEMISTRY, 2009, 21 (04) : 732 - 738
  • [3] Application of Aptamer-based Biosensor in Bisphenol A Detection
    Huang, Lei
    Wang, Xin
    Liu, Sha
    Gao, Zhi-Xian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (02) : 172 - 183
  • [4] An aptamer-based biosensor for sensitive thrombin detection with phthalocyanine@SiO2 mesoporous nanoparticles
    Jiang, Zhou
    Yang, Tingting
    Liu, Minyan
    Hu, Yanli
    Wang, Jian
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 340 - 345
  • [5] Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine
    Yan, Fangfang
    Wang, Fang
    Chen, Zilin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 1380 - 1385
  • [6] A chemiluminescence biosensor for the detection of thrombin based on the aptamer composites
    Lin, Yanna
    Li, Jianbo
    Wang, Yanhui
    Sun, Yuanling
    Ding, Chaofan
    Sun, Weiyan
    Luo, Chuannan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 192 : 153 - 158
  • [7] Sensitive and Homogeneous Detection System with Aptamer-Based Biosensor
    Tsukakoshi, Kaori
    Ikebukuro, Kazunori
    SENSORS AND MATERIALS, 2016, 28 (10) : 1083 - 1089
  • [8] Design of an aptamer-based magnetic adsorbent and biosensor systems for selective and sensitive separation and detection of thrombin
    Bayramoglu, Gulay
    Ozalp, Veli Cengiz
    Oztekin, Merve
    Guler, Ulku
    Salih, Bekir
    Arica, M. Yakup
    TALANTA, 2019, 191 : 59 - 66
  • [9] An aptamer-based biosensor for the detection of lysozyme with gold nanoparticles amplification
    Li, Li-Dong
    Chen, Zheng-Bo
    Zhao, Hong-Tao
    Guo, Lin
    Mu, Xiaojiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01): : 110 - 115
  • [10] DNA aptamer-based sensitive electrochemical biosensor for NAD (H) detection
    Guo, Wenfei
    Wang, Haiyuan
    Wang, Zhaoyang
    Wu, Fandi
    He, Yao
    Liu, Yuan
    Deng, Yan
    Bing, Tao
    Qiu, Liping
    Tan, Weihong
    BIOSENSORS & BIOELECTRONICS, 2025, 271