Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
|
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [41] Intraocular lens power calculation after laser refractive surgery Corrective algorithm for corneal power estimation
    Jin, Haiying
    Holzer, Mike P.
    Rabsilber, Tanja
    Borkenstein, Andreas F.
    Lirnberger, Ii-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01) : 87 - 96
  • [42] Evaluation of Reliability of Formulas for Intraocular Lens Power Calculation After Hyperopic Refractive Surgery
    Boccia, Rosa
    Lanza, Michele
    Luciano, Giuseppe
    Fattore, Italo
    Serra, Luigi
    Ambrosio, Salvatore
    Abbate, Francesco
    Simonelli, Francesca
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [43] Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas
    Martinez-Enriquez, Eduardo
    Perez-Merino, Pablo
    Duran-Poveda, Sonia
    Jimenez-Alfaro, Ignacio
    Marcos, Susana
    SCIENTIFIC REPORTS, 2018, 8
  • [44] Corneal topography and keratometry changes after glued intraocular lens implantation
    Kumar, Dhivya Ashok
    Kaur, Harspreet
    Agarwal, Amar
    Selvaraj, Sajitha
    Pandian, Sathish Kumar
    Chintalpati, Vamsi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08) : 1062 - 1067
  • [45] Updated practical intraocular lens power calculation after refractive surgery
    Jonna, Gowtham
    Channa, Prabjot
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) : 275 - 280
  • [46] Preliminary demonstration of a novel intraocular lens power calculation: the O formula
    Goto, So
    Maeda, Naoyuki
    Ohnuma, Kazuhiko
    Lawu, Tjundewo
    Kawasaki, Ryo
    Koh, Shizuka
    Nishida, Kohji
    Noda, Toru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (11) : 1305 - 1311
  • [47] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    EYE AND VISION, 2018, 5
  • [48] Estimation of effective lens position using a method independent of preoperative keratometry readings
    Dooley, Ian
    Charalampidou, Sofia
    Nolan, John
    Loughman, James
    Molloy, Laura
    Beatty, Stephen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03) : 506 - 512
  • [49] Preliminary validation of an optimized algorithm for intraocular lens power calculation in keratoconus
    Camps, Vicente J.
    Pinero, David P.
    Caravaca, Esteban
    De Fez, Dolores
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (08) : 690 - 699
  • [50] Predictability of Intraocular Lens Power Calculation for Cataract with Keratoconus: A Multicenter Study
    Kamiya, Kazutaka
    Iijima, Kei
    Nobuyuki, Shoji
    Mori, Yosai
    Miyata, Kazunori
    Yamaguchi, Takefumi
    Shimazaki, Jun
    Watanabe, Shinya
    Maeda, Naoyuki
    SCIENTIFIC REPORTS, 2018, 8