Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
|
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [31] Pterygium size and effect on intraocular lens power calculation
    Koc, Mustafa
    Uzel, Mehmet Murat
    Aydemir, Emre
    Yavrum, Fuat
    Kosekahya, Pinar
    Yilmazbas, Pelin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (11) : 1620 - 1625
  • [32] A New Slant on Toric Intraocular Lens Power Calculation
    Savini, Giacomo
    Hoffer, Kenneth J.
    Ducoli, Pietro
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (05) : 348 - 354
  • [33] Comparison of intraocular lens power calculation between standard partial coherence interferometry-based and scheimpflug-based biometers: The importance of lens constant optimization
    Sardari, Sara
    Khabazkhoob, Mehdi
    Jafarzadehpur, Ebrahim
    Fotouhi, Akbar
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2023, 35 (01): : 42 - 49
  • [34] Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (05) : 787 - 792
  • [35] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [36] Accuracy of Intraocular lens power calculation in pediatric traumatic cataract
    Goyal, Priya
    Tibrewal, Shailja
    Ganesh, Suma
    Rath, Soveeta
    Majumdar, Atanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (11) : 1605 - 1610
  • [37] Toric intraocular lens power calculation in cataract patients with keratoconus
    Ton, Yokrat
    Barrett, Graham D.
    Kleinmann, Guy
    Levy, Adi
    Assia, Ehud I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11) : 1389 - 1397
  • [38] Accuracy of Scheimpflug Holladay Equivalent Keratometry Readings after Corneal Refractive Surgery in the Absence of Clinical History
    Bialer, Omer Y.
    Kaiserman, Igor
    Bahar, Irit
    OPHTHALMIC RESEARCH, 2014, 52 (04) : 217 - 223
  • [39] Microincision cataract surgery with implantation of a bitoric intraocular lens using an enhanced program for intraocular lens power calculation
    Lesieur, Gilles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) : 1308 - 1313
  • [40] An Intraocular Lens Power Calculation Formula Based on Optical Coherence Tomography: A Pilot Study
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) : 430 - 437