Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
|
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [21] Comparison of keratometry and total corneal power, as measured by an SS-OCT-based optical biometer, for intraocular lens power calculation in Asian eyes
    Savini, Giacomo
    Taroni, Leonardo
    Jeon, Sohee
    Koh, Kyungmin
    Yang, Hyun Seung
    Abulafia, Adi
    Lupardi, Enrico
    Hoffer, Kenneth J.
    Moramarco, Antonio
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11) : 1117 - 1122
  • [22] Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging
    Schuster, Alexander K.
    Schanzlin, David J.
    Thomas, Karin E.
    Heichel, Christopher W.
    Purcell, Tracy L.
    Barker, Patrick D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (02) : 226 - 231
  • [23] Intraocular lens power calculation using a Placido disk-Scheimpflug tomographer in eyes that had previous myopic corneal excimer laser surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    Schiano-Lomoriello, Domenico
    Barboni, Piero
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08) : 935 - 941
  • [24] Intraocular lens power calculation in eyes with keratoconus
    Savini, Giacomo
    Abbate, Rosa
    Hoffer, Kenneth J.
    Mularoni, Alessandro
    Imburgia, Aurelio
    Avoni, Luca
    D'Eliseo, Domenico
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (05) : 576 - 581
  • [25] Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery
    Lawless, Michael
    Jiang, James Y.
    Hodge, Chris
    Sutton, Gerard
    Roberts, Timothy, V
    Barrett, Graham
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (06) : 749 - 756
  • [26] Intraocular Lens Power Calculation after Small Incision Lenticule Extraction
    Luft, Nikolaus
    Siedlecki, Jakob
    Schworm, Benedikt
    Kreutzer, Thomas C.
    Mayer, Wolfgang J.
    Priglinger, Siegfried G.
    Dirisamer, Martin
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [27] Intraocular lens power calculation in eyes with previous corneal refractive surgery
    Anders, Philipp
    Anders, Lisa-Marie
    Barbara, Adel
    Szentmary, Nora
    Langenbucher, Achim
    Gatzioufas, Zisis
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
  • [28] Clinical Evaluation of the Intraoperative Refraction Technique for Intraocular Lens Power Calculation
    Wong, Albert Chak Ming
    Mak, Shiu Ting
    Tse, Raymond Kwok Kay
    OPHTHALMOLOGY, 2010, 117 (04) : 711 - 716
  • [29] Intraocular lens power calculation after previous laser refractive surgery
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) : 759 - 765
  • [30] The role of the epithelium in intraocular lens and corneal power calculation
    Wendelstein, Jascha A.
    Atchison, David A.
    Gatinel, Damien
    Cooke, David L.
    Langenbucher, Achim
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2025, 45 (02) : 372 - 382