Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 13 条
[1]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[2]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[3]   The shape of the anterior and posterior surface of the aging human cornea [J].
Dubbelman, M ;
Sicarn, VADP ;
Van der Heijde, GL .
VISION RESEARCH, 2006, 46 (6-7) :993-1001
[4]   Validity of the keratometric index: Large population-based study [J].
Fam, Han-Bor ;
Lim, Kooi-Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (04) :686-691
[5]   Corneal power after refractive surgery for myopia: Contact lens method [J].
Haigis, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07) :1397-1411
[6]  
HOFFER KJ, 1994, J CATARACT REFR SURG, V20, P677
[7]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[8]   Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device [J].
Nemeth, Gabor ;
Vajas, Attila ;
Kolozsvari, Bence ;
Berta, Andras ;
Modis, Laszlo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08) :1331-1335
[9]   Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS pentacam [J].
O'Donnell, C ;
Maldonado-Codina, C .
CORNEA, 2005, 24 (08) :920-924
[10]   DEVELOPMENT OF THE SRK/T INTRAOCULAR-LENS IMPLANT POWER CALCULATION FORMULA [J].
RETZLAFF, JA ;
SANDERS, DR ;
KRAFF, MC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03) :333-340