Detector Performance Characterization for High Sensitivity Single-Photon Imaging

被引:3
|
作者
Walker, Katherine L. [1 ]
Cherry, Simon R. [1 ]
Mitchell, Gregory S. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
Gamma-ray detectors; medical imaging; nuclear imaging; spect; SMALL ANIMAL SPECT; GAMMA-CAMERA; MANGANESE; CADMIUM; READOUT; MATRIX;
D O I
10.1109/TNS.2014.2299494
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing detectors for an un-collimated scanner for very high sensitivity single-photon imaging. The scanner consists of two large, thin, closely spaced, pixelated scintillation detectors of either thallium-doped sodium iodide (NaI(Tl)), sodium-doped cesium iodide (CsI(Na)), or bismuth germanate (BGO). The scintillator arrays are interchangeable to optimize performance for a wide range of isotope energies and imaging subjects. For each scintillator, flood histograms were obtained utilizing test gamma sources: Cd-109, Am-241, Co-57, Ba-133, Cs-137, Na-22, and beta source Si-32. Using a 3 mm thick 21 x 41 NaI(Tl) pixelated array (2 mm x 2 mm pixels on a 2.2 mm pitch), read out by two adjacent Hamamatasu H8500 multi-channel photomultiplier tubes (MCPMTs), the energy resolution for Co-57 was 12.2% over the center of the MCPMTs and 45.3% for pixels over the gap, with flood histogram peak-to-valley ratios >6.1 for the center of the MCPMTs and >4.2 for the gap between the two MCPMTs. The NaI(Tl) detector consistently produced peak-to-valley ratios of >1.6 in the center of the MCPMTs for all radioisotopes studied. CsI(Na) and BGO detectors had flood histograms of similar quality to NaI(Tl) at intermediate to high-energies, allowing for optimal imaging across a wide energy range. The measured sensitivity for point sources placed 10 mm from the detector approached 35% for low-energy isotopes and all scintillator materials, which results in an expected system sensitivity (two opposing detectors) of similar to 70% for these isotopes. The 5 mm thick BGO arrays had the greatest efficiency for high-energy isotopes due to the increased stopping power of this material. The measured spatial resolution for Tc-99m for the CsI(Na) detector (1.6 mm pitch) was 7.5 mm FWHM at the aluminum entrance window (1.5 mm from scintillator face), decreasing to 15 mm at a distance of 5 mm from the scintillator face. The NaI(Tl) detector showed similar spatial resolution. This spatial resolution is sufficient for imaging well-localized radiotracer distributions in thin objects, and the very high sensitivity can be used for fast dynamic imaging, or imaging using very low injected doses.
引用
收藏
页码:1118 / 1125
页数:8
相关论文
共 50 条
  • [1] A superconducting nanowire single-photon detector system for single-photon source characterization
    Fitzpatrick, C. R.
    Natarajan, C. M.
    Warburton, R. E.
    Buller, G. S.
    Baek, B.
    Nam, S.
    Miki, S.
    Wang, Z.
    Sasaki, M.
    Sinclair, A. G.
    Hadfield, R. H.
    ADVANCED PHOTON COUNTING TECHNIQUES IV, 2010, 7681
  • [2] A GSO positron/single-photon imaging detector
    Yamamoto, Seiichi
    Matsumoto, Keiichi
    Sakamoto, Setsu
    Senda, Michio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2006, 21 : 106 - 108
  • [3] Spectral sensitivity of the NbN single-photon superconducting detector
    Sobolewski, R
    Xu, Y
    Zheng, XM
    Williams, C
    Zhang, J
    Verevkin, A
    Chulkova, G
    Korneev, A
    Lipatov, A
    Okunev, O
    Smirnov, K
    Gol'tsman, GN
    IEICE TRANSACTIONS ON ELECTRONICS, 2002, E85C (03) : 797 - 802
  • [4] Nanoscale Optical Detector with Single-Photon and Multiphoton Sensitivity
    Bitauld, David
    Marsili, Francesco
    Gaggero, Alessandro
    Mattioli, Francesco
    Leoni, Roberto
    Nejad, Saeedeh Jahanmiri
    Levy, Francis
    Fiore, Andrea
    NANO LETTERS, 2010, 10 (08) : 2977 - 2981
  • [5] A high-performance integrated single-photon detector for telecom wavelengths
    Bethune, DS
    Risk, WP
    Pabst, GW
    JOURNAL OF MODERN OPTICS, 2004, 51 (9-10) : 1359 - 1368
  • [6] A high-performance thermoelectric single-photon detector for telecom wavelengths
    Kuzanyan, Astghik A.
    Kuzanyan, Armen S.
    Nikoghosyan, Vahan R.
    QUANTUM OPTICS AND PHOTON COUNTING, 2019, 11027
  • [7] Development of a GSO positron/single-photon imaging detector
    Yamamoto, S
    Matsumoto, K
    Senda, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02): : 457 - 469
  • [8] Development of a GSO positron/single-photon imaging detector
    Yamamoto, S
    Matsumoto, K
    Senda, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S403 - S403
  • [9] High performance of gated-mode single-photon detector at 1.55 μm
    Wu, Guang
    Zhou, Chunyuan
    Chen, Xiuliang
    Zeng, Heping
    OPTICS COMMUNICATIONS, 2006, 265 (01) : 126 - 131
  • [10] Thermoelectric single-photon detector
    Kuzanyan, A. A.
    Petrosyan, V. A.
    Kuzanyan, A. S.
    INTERNATIONAL SYMPOSIUM ON OPTICS AND ITS APPLICATIONS (OPTICS-2011), 2012, 350