Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis

被引:68
|
作者
Mahmood, Maryam [1 ]
Kendi, Ayse Tuba [2 ]
Farid, Saira [1 ]
Ajmal, Saira [1 ]
Johnson, Geoffrey B. [2 ,3 ]
Baddour, Larry M. [1 ,4 ]
Chareonthaitawee, Panithaya [4 ]
Friedman, Paul A. [4 ]
Sohail, M. Rizwan [1 ,4 ]
机构
[1] Mayo Clin, Div Infect Dis, Dept Med, Coll Med & Sci, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Nucl Med, Dept Radiol, Coll Med & Sci, Rochester, MN USA
[3] Mayo Clin, Dept Immunol, Coll Med & Sci, Rochester, MN USA
[4] Mayo Clin, Dept Cardiovasc Med, Coll Med & Sci, Rochester, MN USA
关键词
CIED; PET; infection; imaging; meta-analysis; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; PATIENT PREPARATION; CARDIAC DEVICE; FDG-PET/CT; ENDOCARDITIS; IMPACT; MANAGEMENT; OUTCOMES; PACEMAKER; ACCURACY;
D O I
10.1007/s12350-017-1063-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveWe performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose (F-18-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections.BackgroundPET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings.MethodsPubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections.ResultsOverall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%).ConclusionUse of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.
引用
收藏
页码:958 / 970
页数:13
相关论文
共 50 条
  • [41] Cardiovascular implantable electronic device infection: delayed vs standard FDG PET-CT imaging
    Leccisotti, Lucia
    Perna, Francesco
    Lago, Mariaelena
    Leo, Milena
    Stefanelli, Antonella
    Calcagni, Maria L.
    Pelargonio, Gemma
    Narducci, Maria L.
    Bencardino, Gianluigi
    Bellocci, Fulvio
    Giordano, Alessandro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) : 622 - 632
  • [42] Prognostic Value of 18F-FDG PET/CT in Surgical NSCLC: A Meta-Analysis
    Liu, Jing
    Dong, Min
    Xing, Ligang
    Sun, Xiaorong
    JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S181 - S181
  • [43] Cardiovascular implantable electronic device infection: delayed vs standard FDG PET-CT imaging
    Lucia Leccisotti
    Francesco Perna
    Mariaelena Lago
    Milena Leo
    Antonella Stefanelli
    Maria L. Calcagni
    Gemma Pelargonio
    Maria L. Narducci
    Gianluigi Bencardino
    Fulvio Bellocci
    Alessandro Giordano
    Journal of Nuclear Cardiology, 2014, 21 : 622 - 632
  • [44] Usefulness of sonication in the microbiological diagnosis of cardiovascular implantable electronic device infections: systematic review, meta-analysis and meta-regression
    Martin-Gutierrez, Guillermo
    Martin-Perez, Carlos
    de la Rosa, Jose Manuel
    Gutierrez-Carretero, Encarnacion
    de Alarcon, Aristides
    Lepe, Jose Antonio
    ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2024, 23 (01)
  • [45] Whole-Body 18F-FDG PET and 18F-FDG PET/CT in Patients with Suspected Paraneoplastic Syndrome: A Systematic Review and Meta-Analysis of Diagnostic Accuracy
    Sheikhbahaei, Sara
    Marcus, Charles V.
    Fragomeni, Roberto S.
    Rowe, Steven P.
    Javadi, Mehrbod S.
    Solnes, Lilja B.
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (07) : 1031 - 1036
  • [46] The role of 18F-FDG PET/CT radiomics in lymphoma
    Rizzo, Alessio
    Triumbari, Elizabeth Katherine Anna
    Gatta, Roberto
    Boldrini, Luca
    Racca, Manuela
    Mayerhoefer, Marius
    Annunziata, Salvatore
    CLINICAL AND TRANSLATIONAL IMAGING, 2021, 9 (06) : 589 - 598
  • [47] Role of 18F-FDG PET/CT in the Diagnosis of Clinically Suspected Marjolin Ulcer
    Ko, Younghwan
    Han, You Mie
    Hwang, Hee Sung
    Kang, Ik Won
    Hwang, Dae Hyun
    Lee, Eil Seong
    Lee, Gyung Kyu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1375 - 1379
  • [48] Diagnostic Performance of 18F-FDG PET or PET/CT for Detection of Post-Transplant Lymphoproliferative Disorder: A Systematic Review and a Bivariate Meta-Analysis
    Ballova, Veronika
    Muoio, Barbara
    Albano, Domenico
    Bertagna, Francesco
    Canziani, Luca
    Ghielmini, Michele
    Ceriani, Luca
    Treglia, Giorgio
    DIAGNOSTICS, 2020, 10 (02)
  • [49] Diagnostic performance of 18F-FDG PET/CT in patients with fever of unknown origin: a meta-analysis
    Hao, Ruirui
    Yuan, Leilei
    Kan, Ying
    Li, Chunlin
    Yang, Jigang
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (07) : 682 - 688
  • [50] 18F-FDG-PET and 18F-FDG-PET/CT in the detection of recurrent or metastatic medullary thyroid carcinoma: A systematic review and meta-analysis
    Cheng, Xu
    Bao, Lihua
    Xu, Zhaoqiang
    Li, Dianfu
    Wang, Jie
    Li, Yongjun
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (02) : 136 - 142