Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis

被引:68
|
作者
Mahmood, Maryam [1 ]
Kendi, Ayse Tuba [2 ]
Farid, Saira [1 ]
Ajmal, Saira [1 ]
Johnson, Geoffrey B. [2 ,3 ]
Baddour, Larry M. [1 ,4 ]
Chareonthaitawee, Panithaya [4 ]
Friedman, Paul A. [4 ]
Sohail, M. Rizwan [1 ,4 ]
机构
[1] Mayo Clin, Div Infect Dis, Dept Med, Coll Med & Sci, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Nucl Med, Dept Radiol, Coll Med & Sci, Rochester, MN USA
[3] Mayo Clin, Dept Immunol, Coll Med & Sci, Rochester, MN USA
[4] Mayo Clin, Dept Cardiovasc Med, Coll Med & Sci, Rochester, MN USA
关键词
CIED; PET; infection; imaging; meta-analysis; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; PATIENT PREPARATION; CARDIAC DEVICE; FDG-PET/CT; ENDOCARDITIS; IMPACT; MANAGEMENT; OUTCOMES; PACEMAKER; ACCURACY;
D O I
10.1007/s12350-017-1063-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveWe performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose (F-18-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections.BackgroundPET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings.MethodsPubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections.ResultsOverall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%).ConclusionUse of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.
引用
收藏
页码:958 / 970
页数:13
相关论文
共 50 条
  • [31] Infection of Ventricular Assist Device Detected and Monitored by 18F-FDG PET/CT
    Dejust, Sebastien
    Guedec-Ghelfi, Renaud
    Blanc-Autrant, Estelle
    Lepers, Yannick
    Morland, David
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (09) : 695 - +
  • [32] Effectiveness of 18F-FDG PET/CT in the diagnosis and staging of osteosarcoma: a meta-analysis of 26 studies
    Liu, Fanxiao
    Zhang, Qingyu
    Zhou, Dongsheng
    Dong, Jinlei
    BMC CANCER, 2019, 19 (1)
  • [33] Effectiveness of 18F-FDG PET/CT in the diagnosis and staging of osteosarcoma: a meta-analysis of 26 studies
    Fanxiao Liu
    Qingyu Zhang
    Dongsheng Zhou
    Jinlei Dong
    BMC Cancer, 19
  • [34] 18F-FDG PET/CT in the diagnosis of occult bacterial infections in children
    del Rosal, Teresa
    Goycochea, Walter A.
    Mendez-Echevarria, Ana
    Garcia-Fernandez de Villalta, Marta
    Baquero-Artigao, Fernando
    Coronado, Monica
    Dolores Marin, Maria
    Albajara, Luis
    EUROPEAN JOURNAL OF PEDIATRICS, 2013, 172 (08) : 1111 - 1115
  • [35] 18F-FDG PET/CT in the diagnosis of occult bacterial infections in children
    Teresa del Rosal
    Walter A. Goycochea
    Ana Méndez-Echevarría
    Marta García-Fernández de Villalta
    Fernando Baquero-Artigao
    Mónica Coronado
    Maria Dolores Marín
    Luis Albajara
    European Journal of Pediatrics, 2013, 172 : 1111 - 1115
  • [36] A systematic review and meta-analysis of pretherapeutic lymph node staging of colorectal cancer by 18F-FDG PET or PET/CT
    Lu, Yu-Yu
    Chen, Jin-Hua
    Ding, Hueisch-Jy
    Chien, Chun-Ru
    Lin, Wan-Yu
    Kao, Chia-Hung
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1127 - 1133
  • [37] The Role of 18F-FDG PET/CT in staging of gallbladder carcinomas
    Arslan, Esra
    Aksoy, Tamer
    Dursun, Nevra
    Gursu, Riza Umar
    Sevinc, Mert Mahsuni
    Cermik, Tevfik Fikret
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2020, 31 (02) : 105 - 112
  • [38] Diagnostic performance of 18F-FDG PET or PET/CT in restaging renal cell carcinoma: a systematic review and meta-analysis
    Ma, Huan
    Shen, Guohua
    Liu, Bin
    Yang, Yuanyou
    Ren, Pengwei
    Kuang, Anren
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (02) : 156 - 163
  • [39] 18F-FDG PET and PET/CT as a diagnostic method for Ewing sarcoma: A systematic review and meta-analysis
    Seth, Nimish
    Seth, Ishith
    Bulloch, Gabriella
    Siu, Adrian Hang Yue
    Guo, Allen
    Chatterjee, Rukmini
    MacManus, Michael
    Donnan, Leo
    PEDIATRIC BLOOD & CANCER, 2022, 69 (03)
  • [40] 18F-FDG positron emission tomography/computed tomography of cardiac implantable electronic device infections
    Soile Pauliina Salomäki
    Antti Saraste
    Jukka Kemppainen
    Saija Hurme
    Juhani Knuuti
    Pirjo Nuutila
    Marko Seppänen
    Anne Roivainen
    Juhani Airaksinen
    Tiina Salo
    Jarmo Oksi
    Laura Pirilä
    Ulla Hohenthal
    Journal of Nuclear Cardiology, 2021, 28 : 2992 - 3003