Analysis of Relationship Between Abnormal Current and Position Detection Error in Sensorless Controller for Interior Permanent-Magnet Brushless DC Motors

被引:23
|
作者
Lee, Dong-Myung [2 ]
Lee, Woo-Cheol [1 ]
机构
[1] Hankyong Natl Univ, Dept Elect Engn, Gyeonggi Do 456749, South Korea
[2] Hongik Univ, Sch Elect & Elect Engn, Seoul 121791, South Korea
关键词
Advance angle; interior permanent-magnet motor; position detection error; sensorless control;
D O I
10.1109/TMAG.2008.923203
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have analyzed the characteristics of terminal voltages used to detect rotor position in interior permanent-magnet (IPM) brushless DC (BLDC) motors in sensorless control by employing a two-phase conduction method. We found that a detected zero crossing point (ZCP) of the open phase voltage advances the real rotor position due to additional voltage components caused by variation of inductance with rotor position. We conclude that the amount of position error is related to rotor saliency, load, and motor speed. We also present the relationship between abnormal currents and amount of position errors in the sensorless controller by using simulations that take into account additional voltages in our model of terminal voltages and motor neutral voltage as well as experiments with a position sensor. We verified the validity of our analysis on IPM motors having various motor parameters under sensorless control.
引用
收藏
页码:2074 / 2081
页数:8
相关论文
共 28 条
  • [21] Modeling and Analysis of Carrier Harmonic based Eddy Current Losses in Interior Permanent Magnet Motors
    Balamurali, Aiswarya
    Lai, Chunyan
    Loukanov, Voiko
    Kar, Narayan C.
    2016 IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (CEFC), 2016,
  • [22] A new standstill position detection technique for nonsalient permanent-magnet synchronous motors using the magnetic anisotropy method
    Persson, Jan
    Markovic, Miroslav
    Perriard, Yves
    IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (02) : 554 - 560
  • [23] A Position Detection Strategy for Sensorless Surface Mounted Permanent Magnet Motors at Low Speed Using Transient Finite-Element Analysis
    Wang, Zhao
    Niu, Shuangxia
    Ho, S. L.
    Fu, W. N.
    Zhu, Jianguo
    IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (02) : 1003 - 1006
  • [24] Low-Speed Sensorless Control Based on Improved Finite Position Set-Observer for Interior Permanent Magnet Synchronous Motors
    Yang, Zebin
    Qian, Can
    Sun, Xiaodong
    Zhu, Zhipeng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (09) : 10921 - 10933
  • [25] An Accurate Full-Speed Position Estimation for Permanent Magnet Synchronous Motors With a DC-Bus Current Sensor
    Zheng, Luhua
    Wu, Chun
    Shentu, Fangting
    Wu, Chenhao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (09) : 11468 - 11478
  • [26] Sensorless Direct Torque Control for Interior Permanent-Magnet Synchronous Motors Using Square-Wave-Type Stator Flux Injection at Low-Speed Regions
    Cho, Dae-Hyun
    Lee, Kyo-Beum
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (01) : 329 - 337
  • [27] Sensorless Direct Torque Control for Interior Permanent-Magnet Synchronous Motors Using Square-Wave-Type Stator Flux Injection at Low-Speed Regions
    Dae-Hyun Cho
    Kyo-Beum Lee
    Journal of Electrical Engineering & Technology, 2022, 17 : 329 - 337
  • [28] Correction of Rotor Position Estimation Error for High-Speed Permanent Magnet Synchronous Motor Sensorless Drive System Based on Minimum-Current-Tracking Method
    Gu, Cong
    Wang, Xiaolin
    Zhang, Feilong
    Deng, Zhiquan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (10) : 8271 - 8280