Quantitative investigation of phase retrieval from X-ray phase-contrast tomographic images

被引:0
|
作者
Moser, H. O. [1 ]
Banas, K. [1 ]
Chen, A. [1 ]
Nghia, T. Vo [1 ]
Jian, L. K. [1 ]
Kalaiselvi, S. M. P. [1 ]
Liu, G. [1 ]
Maniam, S. M. [1 ]
Gu, P. D. [1 ]
Wilkins, S. W. [2 ]
Gureyev, T. E. [2 ]
Mayo, S. C. [2 ]
Cholewa, M. [3 ]
Li, Z. J. [4 ]
机构
[1] Natl Univ Singapore, SSLS, Singapore 117603, Singapore
[2] CSIRO Mfg & Infrastruct Technol, Clayton, Vic 3169, Australia
[3] Monash Univ, Clayton, Vic, Australia
[4] Univ Freiburg, Freiburg, Germany
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY VI | 2008年 / 7078卷
关键词
phase contrast imaging; phase retrieval; reconstruction; micro manufacturing; synchrotron radiation;
D O I
10.1117/12.794497
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray phase-contrast tomographic microimaging is a powerful tool to reveal the internal structure of opaque soft-matter objects that are not easily seen in standard absorption contrast. In such low Z materials, the phase shift of X-rays transmitted can be important as compared to the absorption. An easy experimental set up that exploits refractive contrast fori-nation can deliver images that are providing detailed structural information. Applications are abundant in fields including polymer science and engineering, biology, biomedical engineering, life sciences, zoology, water treatment and filtration, membrane science, and micro/nanomanufacturing. However, available software for absorptive contrast tomography cannot be simply used for structure retrieval as the contrast fori-ning effect is different. In response, CSIRO has developed a reconstruction code for phase-contrast imaging. Here, we present a quantitative comparison of a micro phantom manufactured at SSLS with the object reconstructed by the code using X-ray images taken at SSLS. The phantom is a 500 gm thick 800 mu m diameter cylindrical disk of SU-8 resist having various eccentric cylindrical bores with diameters ranging from 350 gm to 40 mu m. Comparison of these parameters that are well known from design and post-manufacturing measurements with reconstructed ones gives encouraging results.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Investigation on the Dependency of Phase Retrieval Accuracy Versus Edge Enhancement to the Noise Ratio of X-ray Propagation-Based Phase-Contrast Imaging
    Zhang, Lin
    Zhao, Huijuan
    Jiang, Jingying
    Zhang, Limin
    Li, Jiao
    Gao, Feng
    Zhou, Zhongxing
    MICROSCOPY AND MICROANALYSIS, 2019, 25 (05) : 1201 - 1212
  • [42] Imaging renal structures by X-ray phase-contrast microtomography
    Wu, Jin
    Takeda, Tohoru
    Lwin, Thet Thet
    Momose, Atsushi
    Sunaguchi, Naoki
    Fukami, Tadanori
    Yuasa, Tetsuya
    Akatsuka, Takao
    KIDNEY INTERNATIONAL, 2009, 75 (09) : 945 - 951
  • [43] X-ray phase-contrast tomography of porcine fat and rind
    Jensen, Torben H.
    Boettiger, Arvid
    Bech, Martin
    Zanette, Irene
    Weitkamp, Timm
    Rutishauser, Simon
    David, Christian
    Reznikova, Elena
    Mohr, Juergen
    Christensen, Lars Bager
    Olsen, Eli V.
    Feidenhans'l, Robert
    Pfeiffer, Franz
    MEAT SCIENCE, 2011, 88 (03) : 379 - 383
  • [44] Phase-contrast and fluorescent X-ray imaging for biomedical researches
    Takeda, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 38 - 46
  • [45] Edge-illumination x-ray phase-contrast imaging
    Olivo, Alessandro
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2021, 33 (36)
  • [46] Principles of Different X-ray Phase-Contrast Imaging: A Review
    Tao, Siwei
    He, Congxiao
    Hao, Xiang
    Kuang, Cuifang
    Liu, Xu
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [47] Phase-Contrast Tomography with X-ray Hartmann wavefront sensor
    Provinciali, Ginevra Begani
    Cedola, Alessia
    de la Rochefoucauld, Ombeline
    Zeitoun, Philippe
    INTERNATIONAL CONFERENCE ON X-RAY LASERS 2020, 2021, 11886
  • [48] Sensitivity of edge illumination X-ray phase-contrast imaging
    Diemoz, P. C.
    Endrizzi, M.
    Bravin, A.
    Robinson, I. K.
    Olivo, A.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [49] Fourier transform phase retrieval for x-ray phase-contrast imaging based on cascaded Talbot-Lau interferometers
    Huang, Jianheng
    Wali, Faiz
    Lei, Yaohu
    Liu, Xin
    Li, Ji
    OPTICAL ENGINEERING, 2020, 59 (03)
  • [50] X-ray phase-contrast CT imaging of the acupoints based on synchrotron radiation
    Chenglin, Liu
    Xiaohua, Wang
    Hua, Xu
    Fang, Liu
    Ruishan, Dang
    Dongming, Zhang
    Xinyi, Zhang
    Honglan, Xie
    Tiqiao, Xiao
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2014, 196 : 80 - 84