Dose/volume-based evaluation of the accuracy of deformable image registration for the rectum and bladder

被引:29
作者
Thor, Maria [1 ]
Bentzen, Lise [2 ]
Elstrom, Ulrik V. [1 ]
Petersen, Jorgen B. B. [1 ]
Muren, Ludvig Paul [1 ,2 ,3 ]
机构
[1] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[3] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
关键词
PROSTATE-CANCER; CONTOUR PROPAGATION; DOSE-ESCALATION; LYMPH-NODES; RADIOTHERAPY; ORGAN; ROBUSTNESS; ALGORITHM; THERAPY; MOTION;
D O I
10.3109/0284186X.2013.814151
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose. Deformable image registration (DIR) is a key component of image-guided and adaptive strategies in radiotherapy. DIR based on image intensities alone is promising for online applications, but is challenged in regions with low intensity gradients. In this study we have investigated the performance of intensity-based DIR applied to contour propagation of the rectum and bladder, focusing on the consequences in terms of dose/volume parameters. Material and methods. The rectum and bladder volumes were delineated in the planning computed tomography (pCT) scan and in 8-9 repeat CTs (Vmanual) for nine prostate cancer patients. The volumes from the pCT were propagated onto the repeat CTs using intensity-based DIR (Vprop). Dose/volume parameters for Vmanual and Vprop were derived by dose re-calculations following rigid registration on prostate fiducials. Linear regression was used to identify qualitative and quantitative volumetric measures of the DIR performance being associated with the differences in dose/volume parameters. Results. The median differences in dose/volume parameters assessed for Vprop and Vmanual were modest, but individual differences similar to 7 Gy were seen. The observed differences in dose/volume parameters showed strong correlations to the measures of the DIR performance as well as with the volume variations, most pronounced for the rectum (R-2 = 0.63-0.85; p <= 0.05). Conclusion. Limitations in the intensity-based DIR algorithm resulted in large individual differences in dose/volume parameters between propagated and manually segmented volumes, which were correlated with volumetric measures of the DIR performance.
引用
收藏
页码:1411 / 1416
页数:6
相关论文
共 27 条
[1]   Bladder dose accumulation based on a biomechanical deformable image registration algorithm in volumetric modulated arc therapy for prostate cancer [J].
Andersen, E. S. ;
Muren, L. P. ;
Sorensen, T. S. ;
Noe, K. O. ;
Thor, M. ;
Petersen, J. B. ;
Hoyer, M. ;
Bentzen, L. ;
Tanderup, K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :7089-7100
[2]   A significant decrease in rectal volume and diameter during prostate IMRT [J].
Anderson, Nicole S. ;
Yu, James B. ;
Peschel, Richard E. ;
Decker, Roy H. .
RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) :187-191
[3]   Auto-propagation of contours for adaptive prostate radiation therapy [J].
Chao, Ming ;
Xie, Yaoqin ;
Xing, Lei .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :4533-4542
[4]   Clinical impact of margin reduction on late toxicity and short-term biochemical control for patients treated with daily on-line image guided IMRT for prostate cancer [J].
Crehange, Gilles ;
Mirjolet, Celine ;
Gauthier, Melanie ;
Martin, Etienne ;
Truc, Gilles ;
Peignaux-Casasnovas, Karine ;
Azelie, Caroline ;
Bonnetain, Franck ;
Naudy, Suzanne ;
Maingon, Philippe .
RADIOTHERAPY AND ONCOLOGY, 2012, 103 (02) :244-246
[5]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[6]   A deformable image registration method to handle distended rectums in prostate cancer radiotherapy [J].
Gao, Song ;
Zhang, Lifei ;
Wang, He ;
de Crevoisier, Renaud ;
Kuban, Deborah D. ;
Mohan, Radhe ;
Dong, Lei .
MEDICAL PHYSICS, 2006, 33 (09) :3304-3312
[7]   Automated registration of large deformations for adaptive radiation therapy of prostate cancer [J].
Godley, Andrew ;
Ahunbay, Ergun ;
Peng, Cheng ;
Li, X. Allen .
MEDICAL PHYSICS, 2009, 36 (04) :1433-1441
[8]   Does the planning dose-volume histogram represent treatment doses in image-guided prostate radiation therapy? Assessment with cone-beam computerised tomography scans [J].
Hatton, Joan A. ;
Greer, Peter B. ;
Tang, Colin ;
Wright, Philip ;
Capp, Anne ;
Gupta, Sanjiv ;
Parker, Joel ;
Wratten, Chris ;
Denham, James W. .
RADIOTHERAPY AND ONCOLOGY, 2011, 98 (02) :162-168
[9]   Influence of organ motion on conformal vs. intensity-modulated pelvic radiotherapy for prostate cancer [J].
Hysing, Liv Bolstad ;
Skorpen, Tone Nybo ;
Alber, Markus ;
Fjellsbo, Lise Bauge ;
Helle, Svein Inge ;
Muren, Ludvig Paul .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05) :1496-1503
[10]   A coverage probability based method to estimate patient-specific small bowel planning volumes for use in radiotherapy [J].
Hysing, Liv Bolstad ;
Soehn, Matthias ;
Muren, Ludvig P. ;
Alber, Markus .
RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) :407-411