Complications of circular plate fixation for four-corner arthrodesis

被引:72
作者
Shindle, M. K. [1 ]
Burton, K. J. [1 ]
Weiland, A. J. [1 ]
Domb, B. G. [1 ]
Wolfe, S. W. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed Surg, New York, NY 10021 USA
关键词
circular plate; four corner arthrodesis; non-union; dorsal impingement;
D O I
10.1016/j.jhsb.2006.08.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Four corner arthrodesis is an accepted salvage operation for scapholunate advanced collapse and scaphoid non-union advanced collapse. Circular plates were introduced in 1999 and promoted as a rapid and more stable method for this procedure. A retrospective chart review was performed on all patients who were treated with the Spider Limited Wrist Fusion Plate (Kinetikos Medical Inc., San Diego, CA). Sixteen patients were identified and followed clinically and with X-rays for an average of 16 (range 5-38) months. Nine out of the 16 patients (56%) had complications, including nonunion (25%), delayed union (6%), dorsal impingement (25%), radial styloid impingement (6%) and broken screws (13%). The purpose of this study was to compare our complication rate using circular plates with published outcomes using traditional methods of fixation: this study identified a significantly higher complication rate and lower union rate using circular plate fixation for four-corner arthrodesis compared with previously published techniques.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 12 条
[1]   SCAPHOLUNATE ADVANCED COLLAPSE WRIST SALVAGE [J].
ASHMEAD, D ;
WATSON, HK ;
DAMON, C ;
HERBER, S ;
PALY, W .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (05) :741-750
[2]   Capitolunate arthrodesis with scaphoid and triquetrum excision [J].
Calandruccio, JH ;
Gelberman, RH ;
Duncan, SFM ;
Goldfarb, CA ;
Pae, R ;
Gramig, W .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (05) :824-832
[3]   Degenerative arthritis of the wrist: Proximal row carpectomy versus scaphoid excision and four-corner arthrodesis [J].
Cohen, MS ;
Kozin, SH .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (01) :94-104
[4]   Results of four-corner arthrodesis using dorsal circular plate fixation [J].
Kendall, CB ;
Brown, TR ;
Millon, SJ ;
Rudisill, LE ;
Sanders, JL ;
Tanner, SL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (05) :903-907
[5]   CHRONIC LUNOTRIQUETRAL INSTABILITY - DIAGNOSIS AND TREATMENT [J].
KIRSCHENBAUM, D ;
COYLE, MP ;
LEDDY, JP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (06) :1107-1112
[6]   SURGICAL-TREATMENT OF SCAPHOLUNATE ADVANCED COLLAPSE [J].
KRAKAUER, JD ;
BISHOP, AT ;
COONEY, WP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (05) :751-759
[7]   Midcarpal arthrodesis with complete scaphoid excision and interposition bone graft in the treatment of advanced carpal collapse (SNAC/SLAC wrist):: Operative technique and outcome assessment [J].
Sauerbier, M ;
Tränkle, M ;
Linsner, G ;
Bickert, B ;
Germann, G .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (04) :341-345
[8]  
Shin AY., 2001, J Am Soc Surg Hand, V1, P93, DOI [10.1053/jssh.2001.23905., DOI 10.1053/JSSH.2001.23905]
[9]   Complications and outcome of four-corner arthrodesis: Circular plate fixation versus traditional techniques [J].
Vance, MC ;
Hernandez, JD ;
DiDonna, ML ;
Stern, PJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06) :1122-1127
[10]   LIMITED WRIST ARTHRODESIS .2. INTERCARPAL AND RADIOCARPAL COMBINATIONS [J].
WATSON, HK ;
GOODMAN, ML ;
JOHNSON, TR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (03) :223-233