Ultra-low fouling methylimidazolium modified surfaces for the detection of HER2 in breast cancer cell lysates

被引:17
作者
Aube, Alexandra [1 ]
Campbell, Shirley [2 ]
Schmitzer, Andreea R. [1 ]
Claing, Audrey [2 ]
Masson, Jean-Francois [1 ,3 ]
机构
[1] Univ Montreal, Dept Chim, CP 6128 Succ Ctr Ville, Montreal, PQ H3C 3J7, Canada
[2] Univ Montreal, Dept Physiol & Pharmacol, CP 6128 Succ Ctr Ville, Montreal, PQ H3C 3J7, Canada
[3] Quebec Ctr Adv Mat, Quebec City, PQ, Canada
基金
加拿大创新基金会; 加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
SELF-ASSEMBLED MONOLAYERS; IONIC LIQUIDS; PLASMON RESONANCE; SENSITIVE DETECTION; HUMAN SERUM; EXTRACELLULAR DOMAIN; ELECTRICAL DETECTION; GOLD NANOPARTICLES; BIOMARKER PROTEINS; IMMUNOSENSOR;
D O I
10.1039/c7an00056a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We synthesized novel ultra-low fouling ionic liquids and demonstrated their use with surface plasmon resonance (SPR) sensing for the analysis of HER2 in breast cancer cell lysates. Whilst biomarkers are commonly detected in serum, this remains challenging for cancer diagnosis due to their low concentrations in circulation and in some cases, there is a poor correlation between serum and tissue concentrations. Therefore, a cell lysate constitutes an interesting biosample for cancer diagnosis and typing, which has been largely unexploited for chemical biosensing of cancer biomarkers. However, high fouling of surfaces in contact with the cell lysate and the absence of effective surface chemistry to prevent fouling are currently limiting biomarker analysis in cell lysates. To address this challenge, we report the synthesis of 1-(carboxyalkyl)-3-(12-mercaptododecyl)-1H-imidazolium ionic liquids with different anions (Br-, BF4-, PF6-, ClO4-, and NTf2-) and ethyl and pentyl chains to form monolayers and analyse specific proteins from cell lysates. The most efficient ionic liquid monolayer, 1-(carboxyethyl)-3-(12-mercaptododecyl)-1H- imidazolium bromide, was able to eliminate the nonspecific adsorption (surface coverage of 2 +/- 2 ng cm(-2)) of a concentrated cell lysate (protein concentration of similar to 3.5 mg mL(-1)), which was significantly better than carboxy-PEG (surface coverage of 14 +/- 7 ng cm-2), a benchmark monolayer commonly used to reduce nonspecific adsorption. These ionic liquid monolayers were modified with anti-HER2 and the detection of the HER2 breast cancer biomarker was carried out in crude breast cancer cell lysates, as shown with HER2-negative MCF-7 cells spiked with HER2 and with HER2 positive SK-BR-3 cells.
引用
收藏
页码:2343 / 2353
页数:11
相关论文
共 62 条
[1]   A novel antibody-antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode [J].
Arkan, Elham ;
Saber, Reza ;
Karimi, Ziba ;
Shamsipur, Mojtaba .
ANALYTICA CHIMICA ACTA, 2015, 874 :66-74
[2]   Response Monitoring of Acute Lymphoblastic Leukemia Patients Undergoing L-Asparaginase Therapy: Successes and Challenges Associated with Clinical Sample Analysis in Plasmonic Sensing [J].
Aube, Alexandra ;
Charbonneau, David M. ;
Pelletier, Joelle N. ;
Masson, Jean-Francois .
ACS SENSORS, 2016, 1 (11) :1358-1365
[3]   Non-specific Adsorption of Crude Cell Lysate on Surface Plasmon Resonance Sensors [J].
Aube, Alexandra ;
Breault-Turcot, Julien ;
Chaurand, Pierre ;
Pelletier, Joelle N. ;
Masson, Jean-Francois .
LANGMUIR, 2013, 29 (32) :10141-10148
[4]   A survey of state-of-the-art surface chemistries to minimize fouling from human and animal biofluids [J].
Blaszykowski, Christophe ;
Sheikh, Sonia ;
Thompson, Michael .
BIOMATERIALS SCIENCE, 2015, 3 (10) :1335-1370
[5]   Surface chemistry to minimize fouling from blood-based fluids [J].
Blaszykowski, Christophe ;
Sheikh, Sonia ;
Thompson, Michael .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (17) :5599-5612
[6]   Modified peptide monolayer binding His-tagged biomolecules for small ligand screening with SPR biosensors [J].
Bolduc, Olivier R. ;
Lambert-Lanteigne, Patrick ;
Colin, Damien Y. ;
Zhao, Sandy Shuo ;
Proulx, Caroline ;
Boeglin, Damien ;
Lubell, William D. ;
Pelletier, Joelle N. ;
Fethiere, James ;
Ong, Huy ;
Masson, Jean-Francois .
ANALYST, 2011, 136 (15) :3142-3148
[7]   Directly Functionalizable Surface Platform for Protein Arrays in Undiluted Human Blood Plasma [J].
Brault, Norman D. ;
White, Andrew D. ;
Taylor, Allen D. ;
Yu, Qiuming ;
Jiang, Shaoyi .
ANALYTICAL CHEMISTRY, 2013, 85 (03) :1447-1453
[8]   Studies on self-assembled alkanethiol monolayers formed at applied potential on polycrystalline gold electrodes [J].
Brett, CMA ;
Kresak, S ;
Hianik, T ;
Brett, AMO .
ELECTROANALYSIS, 2003, 15 (5-6) :557-565
[9]   Label-free Her2 detection and dissociation constant assessment in diluted human serum using a longitudinal extension mode of a piezoelectric microcantilever sensor [J].
Capobianco, Joseph A. ;
Shih, Wan Y. ;
Adams, Gregory P. ;
Shih, Wei-Heng .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) :349-356
[10]   Label-free, all-electrical, in situ human epidermal growth receptor 2 detection [J].
Capobianco, Joseph A. ;
Shih, Wan Y. ;
Yuan, Qing-An ;
Adams, Gregory P. ;
Shih, Wei-Heng .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (07)