A biomechanical ear model to evaluate middle-ear reconstruction

被引:1
作者
Mojallal, Hamidreza [1 ]
Stieve, Martin [1 ]
Krueger, Ilka [2 ]
Behrens, Peter [2 ]
Mueller, Peter P. [3 ]
Lenarz, Thomas [1 ]
机构
[1] Hannover Med Sch, Dept Otorhinolaryngol, D-30625 Hannover, Germany
[2] Leibniz Univ Hannover, Inst Inorgan Chem, Hannover, Germany
[3] Helmholtz Ctr Infect Res, Braunschweig, Germany
关键词
Mechanical ear model; middle-ear reconstruction; middle-ear prosthesis; sound transmission characteristics; laser Doppler vibrometry; tympanometry; static compliance; air-bone gap; OSSICULAR CHAIN; SOUND-TRANSMISSION; STAPES FOOTPLATE; PROSTHESIS;
D O I
10.3109/14992020903085735
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
In order to evaluate the efficiency of middle-ear prostheses in near-real conditions, an artificial model was developed that approximately simulates the actual geometrical and biomechanical properties of the ear system (excluding the ossicular chain). The sound transmission characteristics of selected commercial middle-ear prostheses and of a synthetic test material were measured using laser Doppler vibrometry (LDV) in this model. The model's realistic properties enabled clinical tympanometry to be used to control the stiffness. In addition the influences of the implant mass on transmission characteristics were investigated. With an averaged displacement between 10 and 100 nm/Pa up to 2000 Hz, the transmission characteristic of the model was comparable with data obtained from the intact middle ear in temporal bone experiments. From the acoustical point of view, no significant material-specific differences could be found. Increasing the mass of the implants to more than 50 mg results in poorer acoustic transmission. In general, changes to the stiffness involving compliance values greater than 3.5 ml and smaller than 0.2 ml led to poorer acoustic transmission.
引用
收藏
页码:876 / 884
页数:9
相关论文
共 34 条
[1]  
Asai M, 1999, ACTA OTO-LARYNGOL, V119, P356
[2]  
BOEHME G, 2005, AUDIOMETRIE HORPRUFU, P25
[3]   The discordant eardrum [J].
Fay, Jonathan P. ;
Puria, Sunil ;
Steele, Charles R. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (52) :19743-19748
[4]   Three-dimensional modeling of middle ear biomechanics and its applications [J].
Gan, RZ ;
Sun, QL ;
Dyer, RK ;
Chang, KH ;
Dormer, KJ .
OTOLOGY & NEUROTOLOGY, 2002, 23 (03) :271-280
[5]   Mass loading on the ossicles and middle ear function [J].
Gan, RZ ;
Dyer, RK ;
Wood, MW ;
Dormer, KJ .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2001, 110 (05) :478-485
[6]   Human middle ear transfer function measured by double laser interferometry system [J].
Gan, TZ ;
Wood, TW ;
Dormer, TJ .
OTOLOGY & NEUROTOLOGY, 2004, 25 (04) :423-435
[7]  
Geyer G, 1999, HNO, V47, P77, DOI 10.1007/s001060050363
[8]  
Gjuric M, 1998, AM J OTOL, V19, P273
[9]   Three-dimensional stapes footplate motion in human temporal bones [J].
Hato, N ;
Stenfelt, S ;
Goode, RL .
AUDIOLOGY AND NEURO-OTOLOGY, 2003, 8 (03) :140-152
[10]  
Holand W., 1990, BIOCERAMICS, V2, P97