Combined approach for non-invasive measurement of liver pathology by MR

被引:0
|
作者
Cowin, Gary J. [1 ]
Jonsson, Julie R. [2 ]
McPherson, Stuart [2 ,3 ,4 ,5 ]
Clouston, Andrew D. [2 ]
Benson, Mark [6 ]
Powell, Elizabeth E. [2 ,4 ,5 ]
Galloway, Graham J. [1 ]
机构
[1] Univ Queensland, Ctr Magnet Resonance, Brisbane, Qld 4072, Australia
[2] Univ Queensland, So Clin Div, Sch Med, Brisbane, Qld 4072, Australia
[3] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[4] Princess Alexandra Hosp, Dept Gastroenterol, Brisbane, Qld 4102, Australia
[5] Princess Alexandra Hosp, Dept Hepatol, Brisbane, Qld 4102, Australia
[6] Princess Alexandra Hosp, Dept Radiol, Brisbane, Qld 4102, Australia
关键词
D O I
10.1016/j.jhep.2009.09.005
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
引用
收藏
页码:1083 / 1084
页数:2
相关论文
共 50 条
  • [31] Non-invasive Measurement of Spleen Stiffness as a prognostic Liver-Marker
    Hofmann-Assmus, Marion
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2018, 56 (04): : 333 - +
  • [32] Measurement of liver stiffness as a non-invasive method for diagnosis of non-alcoholic fatty liver disease
    Yoshioka, Kentaro
    Hashimoto, Senju
    Kawabe, Naoto
    HEPATOLOGY RESEARCH, 2015, 45 (02) : 142 - 151
  • [33] NON-INVASIVE RESURFACING COMBINED WITH TRANSEPIDERMAL
    McDermott, Laura
    LASERS IN SURGERY AND MEDICINE, 2016, 48 : 49 - 50
  • [34] Non-invasive measurement of in-vivo elasticity of skeletal muscles with MR-Elastography
    Kang, Y. -B.
    Oida, T.
    Jung, D. -Y.
    Fukuma, A.
    Azuma, T.
    Okamoto, J.
    Takizawa, O.
    Matsuda, T.
    Tsutsumi, S.
    ASBM7: ADVANCED BIOMATERIALS VII, 2007, 342-343 : 901 - +
  • [35] A Non-invasive Vision Based Approach to Velocity Measurement of Skeleton Training
    Evans, Murray
    Needham, Laurie
    Colyer, Steffi L.
    Cosker, Darren P.
    2020 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS (CVPRW 2020), 2020, : 3885 - 3892
  • [36] Measurement of skin viscoelasticity: A non-invasive approach in allergic contact dermatitis
    Constantin, Maria-Magdalena
    Bucur, Stefana
    Serban, Elena-Daniela
    Olteanu, Rodica
    Bratu, Ovidiu Gabriel
    Constantin, Traian
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 20 (06)
  • [37] Non-invasive Degradation Tracking of Mg Implants in Humans: A Measurement Approach
    Varady, Patrick A.
    Vockensohn, Tim
    Forssmann, Kristin
    Ziegler, Andreas
    Seitz, Jan-Marten
    JOM, 2020, 72 (05) : 1845 - 1850
  • [38] Non-invasive Degradation Tracking of Mg Implants in Humans: A Measurement Approach
    Patrick A. Varady
    Tim Vockensohn
    Kristin Forßmann
    Andreas Ziegler
    Jan-Marten Seitz
    JOM, 2020, 72 : 1845 - 1850
  • [39] Heart Rate Measurement Using Non-invasive Sparse Signal Approach
    Shuaibu, Aliyu Nuhu
    Dajab, Danjuma D.
    Usman, Fahad
    2020 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2021,
  • [40] Abbreviated Multiparametric MR Solution (the "Liver Triple Screen"), the Future of Non-Invasive MR Quantification of Liver Fat, Iron, and Fibrosis
    Low, Gavin
    Chee, Ryan K. W.
    Wong, Yu Jun
    Tandon, Puneeta
    Manolea, Florin
    Locas, Stephanie
    Ferguson, Craig
    Tu, Wendy
    Wilson, Mitchell P.
    DIAGNOSTICS, 2024, 14 (21)