Performance of Composite Outdoor Insulator Under Superimposed Direct and Switching Impulse Voltages

被引:8
|
作者
Pinzan, Davide [1 ]
Branco, Fabio [2 ]
Haddad, Manu A. [1 ]
Slama, Mohammed El Amine [1 ]
Albano, Maurizio [1 ]
Waters, Ronald T. [1 ]
Leite, Helder [2 ]
机构
[1] Cardiff Univ, Adv High Voltage Engn Res Ctr, Cardiff CF10 3AT, Wales
[2] Univ Porto, High Voltage Lab, Dept Elect & Comp Engn, P-4099002 Porto, Portugal
基金
欧盟地平线“2020”;
关键词
Insulators; Conductivity; Flashover; Rain; Switches; Voltage measurement; Standards; Insulator; HVDC; Switching Impulse; Superimposition;
D O I
10.1109/TPWRD.2020.3003980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High Voltage Direct Current (HVDC) systems are increasingly being adopted around the world to integrate renewable resources, increase power transfer, and allow flexible grid operation. HVDC overhead lines play a critical role in this, and focus is needed on the research of composite outdoor insulators failure. In the case of a pole to ground fault of a bipolar scheme, the healthy pole experiences a slow transient overvoltage similar to a Switching Impulse (SI) superimposed on the operational DC voltage. However, there is no standard test for such voltage superimposition. This paper investigates the performance of a composite insulator stressed with such superimposition under dry and rain conditions. To determine the direct voltage influence on the flashover voltage, the results have been compared with the SI only case. Four different rain conductivities have been used in the test program because these insulators can be exposed to different acid conductive rain types, typical of industrialized environments. Both vertical and horizontal orientations have been studied. It was possible to conclude that, in most cases, the direct voltage pre-energization has a negative impact on the flashover performance. The increase in rain conductivity leads to lower flashover values, and the horizontal orientation outperforms the vertical configuration. Under these test conditions, the flashover voltages were all larger than a typical DC operational switching surge. Thus, in the case of pole to ground fault, the healthy pole failure risk appears to be low. However, further research is needed on higher voltages and polluted conditions.
引用
收藏
页码:1193 / 1201
页数:9
相关论文
共 50 条
  • [21] On the performance of a polycrystalline PV panel under different impulse voltages and temperatures
    Ahmad, N. I.
    Ab-Kadir, M. Z. A.
    Izadi, M.
    Zaini, N. H.
    Radzi, M. A. M.
    Azis, N.
    Hasan, W. Z. Wan
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [22] Analysis of sphere-rod gaps under standard lightning and switching impulse voltages
    Gourgoulis, DE
    Mikropoulos, PN
    Stassinopoulos, CA
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1997, 144 (01) : 11 - 16
  • [24] Transient Electric Field Computation for GIS Insulator Under Switching Impulse Voltage
    Yang, Xi
    Zhan, Xuhai
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 227 - 230
  • [25] Sparkover in the conductor-rod and conductor-plane test gaps under composite slow front impulse direct voltages
    Allen, NL
    Huang, CF
    Cornick, KJ
    Greaves, DA
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1999, 146 (03) : 135 - 141
  • [26] Installing Insulation Jacket to Improve Outdoor Insulation Performance of Composite Insulator
    Mei, Hongwei
    Peng, Gongmao
    Dai, Hanqi
    Wang, Liming
    Guan, Zhicheng
    Cao, Linfeng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 2004 - 2012
  • [27] BREAKDOWN OF A COAXIAL-CYLINDER GAP IN SF6 UNDER SWITCHING IMPULSE VOLTAGES
    LEGROS, WP
    MORANT, MM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (04): : 849 - 854
  • [28] Electrical Tree Initiation Characteristics Under DC-impulse Composite Voltages in XLPE
    Liu H.
    Li Y.
    Zhang M.
    Xu X.
    Liu Y.
    Zheng X.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (08): : 2637 - 2643
  • [29] BEHAVIOR OF AIR INSULATING GAPS OF DC SYSTEMS UNDER IMPULSE, DC AND COMPOSITE VOLTAGES
    MENEMENLIS, C
    HARBEC, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (06): : 2065 - 2075
  • [30] Breakdown characteristics of gas-filled transformers and reactors under lightning and switching impulse voltages
    Yamamoto, Takashi
    Ueta, Genyo
    Okabe, Shigemitsu
    Yoshida, Ikki
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (04) : 508 - 512