Biophysics of cardiopulmonary resuscitation with periodic z-axis acceleration or abdominal compression at aortic resonant frequencies

被引:13
作者
Babbs, CF
机构
[1] Purdue Univ, Dept Basic Med Sci, W Lafayette, IN 47907 USA
[2] Indiana Univ, Sch Med, Indianapolis, IN 46204 USA
关键词
abdominal; aorta; coronary perfusion pressure; heart arrest; IAC-CPR; inertia; pGz; pulse wave velocity; reflection; resonance;
D O I
10.1016/j.resuscitation.2005.09.023
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Periodic z-axis acceleration (pGz)-CPR involves an oscillating motion of a whole patient in the head-to-foot dimension on a mechanized table. The method is able to sustain blood flow and long-term survival during and after prolonged cardiac arrest in anesthetized pigs. However, the exact mechanism by which circulation of blood is created has remained unknown. Objectives: To explain the hemodynamic mechanism of pGz-CPR and to suggest some theoretically useful improvements. Method: Computer modeling using a hybrid analytical-numerical approach, based upon Newton's second taw of motion for fluid columns in the aorta and vena cavae, Ohm's taw for resistive flow through vascular beds, and a 10-compartment representation of the adult human circulation. This idealized 70-kg human model is exercised to explore the effects upon systemic perfusion pressure of whole body z-axis acceleration at frequencies ranging from 0.5 to 5 Hz. The results, in turn, suggested studies of abdominal compression at these frequencies. Results and conclusions: Blood motion induced in great vessels by periodic z-axis acceleration causes systemic perfusion when cardiac valves are competent. Blood flow is a function of the frequency of oscillation. At 3.5 Hz, periodic acceleration using ::+/- 0.6G and +/- 1.2cm oscillations induces forward blood flow of 2.1 L/min and systemic perfusion pressure of 47 mmHg. A form of resonance occurs at the frequency for peak-flow, in which the period of oscillation matches the round-trip transit time for reflected pulse waves in the aorta. For +/- 1.0G acceleration at 3.5 Hz, systemic perfusion pressure is 80 mmHg and forward flow is 3.8 L/min in the adult human model with longitudinal z-axis motion of only +/- 2cm. Similar results can be obtained using abdominal compression to excite resonant pressure-volume waves in the aorta. For 20 mmHg abdominal pressure pulses at 3.8 Hz, systemic perfusion pressure is 71 mmHg and forward flow is 2.8 L/min. pGz-CPR and high-frequency abdominal CPR are the physically realistic means of generating artificial circulation during cardiac arrest. These techniques have fundamental mechanisms and practical features quite different from those of conventional CPR and the potential to generate superior systemic perfusion. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:455 / 469
页数:15
相关论文
共 26 条
[1]   Noninvasive motion ventilation (NIMV): a novel approach to ventilatory support [J].
Adams, JA ;
Mangino, MJ ;
Bassuk, J ;
Inman, DM ;
Sackner, MA .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (06) :2438-2446
[2]   Cardiopulmonary resuscitation (CPR) using periodic acceleration (pGz) in an older porcine model of ventricular fibrillation [J].
Adams, JA ;
Wu, DM ;
Bassuk, J ;
Kurlansky, P .
RESUSCITATION, 2004, 60 (03) :327-334
[3]   Survival and normal neurological outcome after CPR with periodic Gz acceleration and vasopressin [J].
Adams, JA ;
Bassuk, J ;
Wu, DM ;
Kurlansky, P .
RESUSCITATION, 2003, 56 (02) :215-221
[4]   Novel CPR with periodic Gz acceleration [J].
Adams, JA ;
Mangino, MJ ;
Bassuk, J ;
Kurlansky, P ;
Sackner, MA .
RESUSCITATION, 2001, 51 (01) :55-62
[5]   Regional blood flow during periodic acceleration [J].
Adams, JA ;
Mangino, MJ ;
Bassuk, J ;
Kurlansky, P ;
Sackner, MA .
CRITICAL CARE MEDICINE, 2001, 29 (10) :1983-1988
[6]   CPR techniques that combine chest and abdominal compression and decompression - Hemodynamic insights from a spreadsheet model [J].
Babbs, CF .
CIRCULATION, 1999, 100 (21) :2146-2152
[7]   Effects of an impedance threshold valve upon hemodynamics in Standard CPR: Studies in a refined computational model [J].
Babbs, CF .
RESUSCITATION, 2005, 66 (03) :335-345
[8]   CARDIAC, THORACIC, AND ABDOMINAL PUMP MECHANISMS IN CARDIOPULMONARY RESUSCITATION - STUDIES IN AN ELECTRICAL MODEL OF THE CIRCULATION [J].
BABBS, CF ;
WEAVER, JC ;
RALSTON, SH ;
GEDDES, LA .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1984, 2 (04) :299-308
[9]   THEORETICAL ADVANTAGES OF ABDOMINAL COUNTERPULSATION IN CPR AS DEMONSTRATED IN A SIMPLE ELECTRICAL MODEL OF THE CIRCULATION [J].
BABBS, CF ;
RALSTON, SH ;
GEDDES, LA .
ANNALS OF EMERGENCY MEDICINE, 1984, 13 (09) :660-671
[10]   Transventricular pressure-velocity wave propagation in diastole: adherence to the Moens-Korteweg equation [J].
Brennan, EG ;
O'Hare, NJ ;
Walsh, MJ .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (01) :117-123