An assessment of the reliability and standardisation of tests used to elicit reference muscular actions for electromyographical normalisation

被引:50
作者
Ball, N. [1 ]
Scurr, J. [1 ]
机构
[1] Univ Portsmouth, Dept Sport & Exercise Sci, Portsmouth PO1 2ER, Hants, England
关键词
Reliability; Sprint; Isometric; Isokinetic; Squat jump; TEST-RETEST RELIABILITY; SURFACE ELECTROMYOGRAPHY; VERTICAL JUMP; TRICEPS SURAE; EMG; REPRODUCIBILITY; VALIDITY; REPEATABILITY; CONTRACTIONS; AMPLITUDE;
D O I
10.1016/j.jelekin.2008.09.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Prior to implementing a normalisation method, the standardisation and reliability of the method needs to be examined. This investigation aimed to assess the reliability of EMG amplitudes and test outputs from proposed normalisation methods for the triceps surae. Sixteen participants completed isometric (maximum and sub-maximum); isokinetic (1.05 rad/s, 1.31 rad/s and 1 83 rad/s) squat jump and 20 m sprint conditions. on 3 separate occasions over I week. The EMG data was collected from the medial and lateral gastrocnemius (MG and LG) and soleus (SOL) Log transformed typical error measurements (TEMCV%) assessed EMG signal and test output reliability across the three sessions Only the squat jump provided acceptable EMG reliability for all muscles both between days (SOL: 13%; MG: 14.5%; LG: 11.8%) and between weeks (SOL: 14.5%, MG: 12.9%; LG: 8 SIX), with the sprint only showing poor reliability in the LG between days (16.3%) Acceptable reliability for the isometric and isokinetic conditions were muscle and re-test period dependant. Reliable output was found for the squat jump (4.1% and 3.6%), sprint (0.8% and 0.6%) and 1 RM plantar flexion test (2.8% and 3.5%) between days and weeks, respectively. Isokinetic plantar flexion displayed poor reliability at all velocities between days and weeks. It was concluded that the squat jump provides a standardised and reproducible reference EMG value for the triceps surae for use as a normalisation method. (C) 2008 Elsevier Ltd All rights reserved
引用
收藏
页码:81 / 88
页数:8
相关论文
共 55 条
[1]   EMG SIGNAL AMPLITUDE NORMALIZATION TECHNIQUE IN STRETCH-SHORTENING CYCLE MOVEMENTS [J].
ALLISON, GT ;
MARSHALL, RN ;
SINGER, KP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1993, 3 (04) :236-244
[2]  
[Anonymous], 2004, DATA ANAL RES SPORT
[3]   Influence of leg stiffness and its effect on myodynamic jumping performance [J].
Arampatzis, A ;
Schade, F ;
Walsh, M ;
Brüggemann, GP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2001, 11 (05) :355-364
[4]  
Araujo R C, 2000, Electromyogr Clin Neurophysiol, V40, P225
[5]  
Arteaga R, 2000, J SPORT MED PHYS FIT, V40, P26
[6]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[7]  
BALL N, 2007, 12 ANN C EUR COLL SP
[8]  
Bamman MM, 1997, J STRENGTH COND RES, V11, P68
[9]   Time-motion analysis and physiological data of elite under19-year-old basketball players during competition [J].
Ben Abdelkrim, Nidhal ;
El Fazaa, Saloua ;
El Ati, Jalila .
BRITISH JOURNAL OF SPORTS MEDICINE, 2007, 41 (02) :69-75
[10]  
Blazevich AJ, 2002, J STRENGTH COND RES, V16, P298