Accuracy of Computed Tomography-Guided Joint Aspiration and Computed Tomography Findings for Prediction of Infected Hip Prosthesis

被引:17
作者
Isern-Kebschull, Jaime [1 ]
Tomas, Xavier [1 ]
Isabel Garcia-Diez, Ana [1 ]
Morata, Laura [2 ]
Rios, Jose [3 ]
Soriano, Alex [2 ]
机构
[1] Univ Barcelona, Hosp Clin, Dept Radiol, Barcelona, Spain
[2] Univ Barcelona, Hosp Clin, Dept Infect Dis, Barcelona, Spain
[3] Inst Invest Biomed August Pi i Sunyer IDIBAPS, Stat & Methodol Support Serv, Stat Unit, Barcelona, Spain
关键词
CT-joint aspiration; total hip arthroplasty; revision surgery; septic hip prosthesis; lymphadenopathy; ARTHROPLASTY; DIAGNOSIS; EFFICACY; CT;
D O I
10.1016/j.arth.2019.04.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Infection after total hip arthroplasty remains a diagnostic challenge. We assessed the accuracy of computed tomography (CT)-guided joint aspiration combined with CT findings for prediction of septic hip prosthesis before revision surgery. Methods: A total of 96 patients (64.6% men; mean age, 68 years) scheduled for elective revision surgery due to suspicion of infection after total hip arthroplasty underwent CT-guided joint aspiration. Volume and microbiological cultures of aspirated fluid and salient findings on CT scans, including periprosthetic soft-tissue mass, malpositioning of the prosthesis, periprosthetic osteolysis, reactive enlarged lymph nodes, and heterotopic ossification, were assessed by a blinded radiologist. Results: Septic hip prosthesis was shown on revision surgery in 35 patients (36.4%), with Staphylococcus epidermidis isolated in 54.3% of cases. Culture of the aspirated fluid yielded the same microorganism in 24 patients (68.6%). The accuracy of preoperative CT-guided joint aspiration was 86.5%. High volume (>1 mL) of aspirated fluid was recorded in 32 patients (33.3%). In the multivariate analysis, high volume on CT aspiration, accumulation of soft tissue exceeding the joint margin, osteolysis without bone insufflation, and enlarged iliac lymph nodes were significant predictors of infected hip prosthesis. Similar results were obtained after adjustment of the model by the presence of aggressive granulomatosis. Conclusion: Preoperative CT-guided joint aspiration is accurate to diagnose septic hip prosthesis based on CT imaging findings and volume and bacterial culture of the aspirated fluid. Enlarged iliac lymph nodes emerged as a strong predictor of infection. (c) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:1776 / 1782
页数:7
相关论文
共 24 条
  • [1] THE VALUE OF ASPIRATION OF THE HIP-JOINT BEFORE REVISION TOTAL HIP-ARTHROPLASTY
    BARRACK, RL
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (01) : 66 - 76
  • [2] Painful infection at the site of hip prosthesis:: CT imaging
    Cyteval, C
    Hamm, V
    Sarrabère, MP
    Lopez, FM
    Maury, P
    Taourel, P
    [J]. RADIOLOGY, 2002, 224 (02) : 477 - 483
  • [3] Ultrasound for diagnosis of infection in revision total hip arthroplasty
    Eisler, T
    Svensson, O
    Engström, CF
    Reinholt, FP
    Lundberg, C
    Wejkner, B
    Schmalholz, A
    Elmstedt, E
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (08) : 1010 - 1017
  • [4] Musculoskeletal infection: Role of CT in the emergency department
    Fayad, Laura M.
    Carrino, John A.
    Fishman, Elliot K.
    [J]. RADIOGRAPHICS, 2007, 27 (06) : 1723 - 1736
  • [5] Aspiration as a guide to sepsis in revision total hip arthroplasty
    Fehring, TK
    Cohen, B
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (05) : 543 - 547
  • [6] Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
    Hjorth, Mette Holm
    Mechlenburg, Inger
    Soballe, Kjeld
    Roemer, Lone
    Jakobsen, Stig Storgaard
    Stilling, Maiken
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (07) : 2279 - 2286
  • [7] Aspiration of the hip joint before revision total hip arthroplasty - Clinical and laboratory factors influencing attainment of a positive culture
    Lachiewicz, PF
    Rogers, GD
    Thomason, HC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05) : 749 - 754
  • [8] Levitsky K A, 1991, J Arthroplasty, V6, P237, DOI 10.1016/S0883-5403(06)80170-1
  • [9] Lima Ana Lucia L, 2013, Interdiscip Perspect Infect Dis, V2013, P542796, DOI 10.1155/2013/542796
  • [10] Imaging in peri-prosthetic assessment: an orthopaedic perspective
    Lohmann, Christoph H.
    Rampal, Sanjiv
    Lohrengel, Martin
    Singh, Gurpal