Directly Suspended Drop MicroExtraction (DSDME); Air-Assisted Dispersive Liquid-Liquid MicroExtraction (AADLLME); Doxepin; Plasma; Urine; Water analysis; UV-Vis spectrophotometer; BAR SORPTIVE EXTRACTION; ORGANIC-SOLVENTS LIGHTER; PHASE MICROEXTRACTION; ANTIDEPRESSANT DRUGS; MASS-SPECTROMETRY; HUMAN PLASMA; HUMAN SERUM; CHROMATOGRAPHY; AMITRIPTYLINE; URINE;
D O I
10.30492/IJCCE.2020.38977
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The present research describes the use of directly suspended drop microextraction and air-assisted dispersive liquid-liquid microextraction method coupled with UV-Vis spectrophotometer for the analysis of doxepin in water and biological samples. Several important parameters which influence the extraction efficiencies of these two microextraction methods, such as the kind of extracting solvent, volume of the aqueous sample solution (donor phase), volume of the organic extraction solvent (acceptor phase), pH of the donor phase, salt effect, extraction time, stirring rate and number of the air injection were investigated. Under the optimal conditions the enrichment factors were above than 30. The linearity of the methods has been investigated between the ranges of 0.005-1.5 and 0.003-1 mu g/mL. The precisions of two methods which are based on the average relative standard deviations are lower than 6, for three different concentrations of the analyte. Finally, the proposed methods were applied for the determination of doxepin in real samples including environmental water, urine and human plasma samples under the optimal conditions and the reasonable relative recoveries were obtained.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 35 条
[1]   Solid phase headspace microextraction of tricyclic antidepressants using a directly prepared nanocomposite consisting of graphene, CTAB and polyaniline [J].
Abedi, Hamid ;
Ebrahimzadeh, Homeira ;
Ghasemi, Jahan B. .
MICROCHIMICA ACTA, 2015, 182 (3-4) :633-641
[2]  
Almudever P., 2004, J CHROMATOGR B, V102, P47
[3]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]   Tandem dispersive liquid-liquid microextraction as an efficient method for determination of basic drugs in complicated matrices [J].
Bazregar, Mohammad ;
Rajabi, Maryam ;
Yamini, Yadollah ;
Saffarzadeh, Zahra ;
Asghari, Alireza .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1429 :13-21
[5]  
Dawson A.H., 2004, MED TOXICOL, P834
[6]   Hollow fiber-based liquid phase microextraction combined with high-performance liquid chromatography for extraction and determination of some antidepressant drugs in biological fluids [J].
Esrafili, Ali ;
Yamini, Yadollah ;
Shariati, Shahab .
ANALYTICA CHIMICA ACTA, 2007, 604 (02) :127-133
[7]  
Farag RS., 2013, Int J Chem Anal Sci, V4, P120, DOI [DOI 10.1016/J.IJCAS.2013.06.001, 10.1016/j.ijcas.2013.06.001]
[8]   Air-assisted liquid-liquid microextraction method as a novel microextraction technique; Application in extraction and preconcentration of phthalate esters in aqueous sample followed by gas chromatography-flame ionization detection [J].
Farajzadeh, Mir Ali ;
Mogaddam, Mohammad Reza Afshar .
ANALYTICA CHIMICA ACTA, 2012, 728 :31-38
[9]   Validation of a high-performance liquid chromatography method for tramadol and o-desmethyltramadol in human plasma using solid-phase extraction [J].
Gan, SH ;
Ismail, R .
JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (02) :325-335
[10]   Ionic liquid based dispersive liquid liquid microextraction coupled with micro-solid phase extraction of antidepressant drugs from environmental water samples [J].
Ge, Dandan ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1317 :217-222