Cesarean section scar diverticulum evaluation by saline contrast-enhanced magnetic resonance imaging: The relationship between variable parameters and longer menstrual bleeding

被引:23
|
作者
Yao, Min [1 ]
Wang, Wenjing [2 ]
Zhou, Jieru [1 ]
Sun, Minghua [2 ]
Zhu, Jialiang [2 ]
Chen, Pin [3 ]
Wang, Xipeng [1 ]
机构
[1] Tongji Univ, Shanghai Matern & Infant Hosp 1, Dept Gynecol, Shanghai, Peoples R China
[2] Tongji Univ, Shanghai Matern & Infant Hosp 1, Dept Radiol, Shanghai, Peoples R China
[3] Tongji Univ, Shanghai Matern & Infant Hosp 1, Dept Ultrasonog, Shanghai, Peoples R China
关键词
cesarean section diverticulum; menstrual bleeding; MRI; transvaginal ultrasound; TRANSVAGINAL SONOGRAPHY; CLINICAL SYMPTOMS; UTERINE INCISION; SONOHYSTEROGRAPHY; DEFECTS; DEHISCENCE; DELIVERY;
D O I
10.1111/jog.13255
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
AimThis study was conducted to determine a more accurate imaging method for the diagnosis of cesarean scar diverticulum (CSD) and to identify the parameters of CSD strongly associated with prolonged menstrual bleeding. MethodsWe enrolled 282 women with a history of cesarean section (CS) who presented with prolonged menstrual bleeding between January 2012 and May 2015. Transvaginal ultrasound, general magnetic resonance imaging (MRI) and contrast-enhanced MRI were used to diagnose CSD. Five parameters were compared among the imaging modalities: length, width, depth and thickness of the remaining muscular layer (TRM) of CSD and the depth/TRM ratio. Correlation between the five parameters and days of menstrual bleeding was performed. Finally, multivariate analysis was used to determine the parameters associated with menstrual bleeding longer than 14 days. ResultsContrast-enhanced MRI yielded greater length or width or thinner TRM of CSD compared with MRI and transvaginal ultrasound. CSD size did not significantly differ between women who had undergone one and two CSs. Correlation analysis revealed that CSD (P = 0.038) and TRM (P = 0.003) lengths were significantly associated with days of menstrual bleeding. Longer than 14 days of bleeding was defined by cut-off values of 2.15 mm for TRM and 13.85 mm for length. TRM and number of CSs were strongly associated with menstrual bleeding longer than 14 days. ConclusionsCE-MRI is a relatively accurate and efficient imaging method for the diagnosis of CSD. A cut-off value of TRM of 2.15 mm is the most important parameter associated with menstrual bleeding longer than 14 days.
引用
收藏
页码:696 / 704
页数:9
相关论文
共 50 条
  • [31] Evaluation of Tumor Hypoxia in C6 Glioma Rat Model With Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Hou, Weishu
    Xue, Yangyang
    Tang, Wei
    Pan, Hongli
    Xu, Man
    Li, Xiaohu
    Bi, Sixing
    Shen, Yujun
    Qian, Yinfeng
    Yu, Yongqiang
    ACADEMIC RADIOLOGY, 2019, 26 (08) : E224 - E232
  • [32] Prospective Comparison of Contrast-Enhanced Ultrasound and Magnetic Resonance Imaging to Computer Tomography for the Evaluation of Complex Cystic Renal Lesions
    Vogel, Dechen W. Tshering
    Kiss, Bernhard
    Heverhagen, Johannes T.
    Benackova, Katarina
    Burkhard, Fiona
    Mueller, Martin
    Uehlinger, Dominik
    Arampatzis, Spyridon
    UROLOGY, 2021, 154 : 320 - 325
  • [33] Pretreatment Evaluation of Microcirculation by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Survival in Primary Rectal Cancer Patients
    DeVries, Alexander Friedrich
    Piringer, Gudrun
    Kremser, Christian
    Judmaier, Werner
    Saely, Christoph Hubert
    Lukas, Peter
    Oefner, Dietmar
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (05): : 1161 - 1167
  • [34] Dynamic contrast-enhanced magnetic resonance imaging for characterising nasopharyngeal carcinoma: comparison of semiquantitative and quantitative parameters and correlation with tumour stage
    Huang, Bingsheng
    Wong, Chun-Sing
    Whitcher, Brandon
    Kwong, Dora Lai-Wan
    Lai, Vincent
    Chan, Queenie
    Khong, Pek-Lan
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1495 - 1502
  • [35] Differentiation between early rheumatoid arthritis patients and healthy persons by conventional and dynamic contrast-enhanced magnetic resonance imaging
    Axelsen, M. B.
    Ejbjerg, B. J.
    Hetland, M. L.
    Skjodt, H.
    Majgaard, O.
    Lauridsen, U. B.
    Horslev-Petersen, K.
    Boesen, M.
    Kubassova, O.
    Bliddal, H.
    Ostergaard, M.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2014, 43 (02) : 109 - 118
  • [36] Evaluation of the efficacy of neoadjuvant chemotherapy for breast cancer using diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging
    Xu, H. D.
    Zhang, Y. Q.
    NEOPLASMA, 2017, 64 (03) : 430 - 436
  • [37] Multiple parameters from ultrafast dynamic contrast-enhanced magnetic resonance imaging to discriminate between benign and malignant breast lesions: Comparison with apparent diffusion coefficient
    Cao, Ying
    Wang, Xiaoxia
    Shi, Jinfang
    Zeng, Xiangfei
    Du, Lihong
    Li, Qing
    Nickel, Dominik
    Zhou, Xiaoyu
    Zhang, Jiuquan
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (06) : 275 - 283
  • [38] Evaluation of pancreatic cancer by multiple breath-hold dynamic contrast-enhanced magnetic resonance imaging at 3.0T
    Yao, Xiuzhong
    Zeng, Mengsu
    Wang, He
    Sun, Fei
    Rao, Shengxiang
    Ji, Yuan
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : E917 - E922
  • [39] Dynamic Contrast-enhanced Magnetic Resonance Imaging in the Early Evaluation of Anti-angiogenic Therapy in Metastatic Renal Cell Carcinoma
    Panebianco, Valeria
    Iacovelli, Roberto
    Barchetti, Flavio
    Altavilla, Amelia
    Forte, Valerio
    Sciarra, Alessandro
    Cortesi, Enrico
    Catalano, Carlo
    ANTICANCER RESEARCH, 2013, 33 (12) : 5663 - 5666
  • [40] Evaluation of dynamic contrast-enhanced magnetic resonance imaging and diffusion-weighted imaging for predicting muscular hyperplasia/hypertrophy in Crohn's disease
    Yu, Lin
    Hu, Shun
    Huang, Fu-Chen
    Wu, Yin-Chen
    Zheng, Xian-Ying
    ABDOMINAL RADIOLOGY, 2022, 47 (05) : 1714 - 1724