European Multicenter Study for the Evaluation of a Dual-Layer Flow-Diverting Stent for Treatment of Wide-Neck Intracranial Aneurysms: The European Flow-Redirection Intraluminal Device Study

被引:74
作者
Killer-Oberpfalzer, M. [1 ]
Kocer, N. [2 ]
Griessenauer, C. J. [1 ,3 ]
Janssen, H. [4 ]
Engelhorn, T. [4 ,5 ]
Holtmannspotter, M. [6 ]
Buhk, J. H. [7 ]
Finkenzeller, T.
Fesl, G. [8 ]
Trenkler, J. [9 ]
Reith, W. [10 ]
Berlis, A. [11 ]
Hausegger, K. [12 ]
Augustin, M. [13 ]
Islak, C. [2 ]
Minnich, B. [14 ]
Moehlenbruch, M. [15 ]
机构
[1] Paracelsus Med Univ, Dept Neurol, Res Inst Neurointervent, Salzburg, Austria
[2] Istanbul Univ, Cerrahpasa Med Sch, Dept Neuroradiol, Istanbul, Turkey
[3] Geisinger Hlth, Dept Neurosurg, Danville, PA USA
[4] Paracelsus Med Univ, Inst Radiol & Neuroradiol, Klinikum Nuernberg Sued, Nurnberg, Germany
[5] Univ Hosp, Dept Neuroradiol, Erlangen, Germany
[6] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
[7] Univ Hosp Hamburg, Dept Neuroradiol, Eppendorf, Germany
[8] Univ Munich, Klinikum Grosshadern, Dept Neuroradiol, Munich, Germany
[9] Kepler Univ Klinikum, Dept Neuroradiol, Linz, Austria
[10] Univ Klinikum Saarlandes, Klin Diagnost & Intervent Neuroradiol, Homburg, Germany
[11] Klinikum Augsburg, Klin Diagnost Radiol & Neuroradiol, Augsburg, Germany
[12] Klinikum Klagenfurt, Dept Diagnost & Intervent Radiol, Klagenfurt, Austria
[13] Univ Hosp, Dept Radiol, Graz, Austria
[14] Univ Salzburg, Dept Cell Biol & Physiol, Salzburg, Austria
[15] Univ Klinikum Heidelberg, Dept Neuroradiol, Heidelberg, Germany
关键词
PIPELINE EMBOLIZATION; DIVERSION; EFFICACY; SAFETY;
D O I
10.3174/ajnr.A5592
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Endoluminal reconstruction with flow-diverting stents represents a widely accepted technique for the treatment of complex intracranial aneurysms. This European registry study analyzed the initial experience of 15 neurovascular centers with the Flow-Redirection Intraluminal Device (FRED) system. MATERIALS AND METHODS: Consecutive patients with intracranial aneurysms treated with the FRED between February 2012 and March 2015 were retrospectively reviewed. Complications and adverse events, transient and permanent morbidity, mortality, and occlusion rates were evaluated. RESULTS: During the defined study period, 579 aneurysms in 531 patients (median age, 54 years; range, 13-86 years) were treated with the FRED. Seven percent of patients were treated in the acute phase (3 days) of aneurysm rupture. The median aneurysm size was 7.6 mm (range, 1-36.6 mm), and the median neck size 4.5 mm (range, 1-30 mm). Angiographic follow-up of >3 months was available for 516 (89.1%) aneurysms. There was progressive occlusion witnessed with time, with complete occlusion in 18 (20%) aneurysms followed for up to 90 14 days, 141 (82.5%) for 180 +/- 20 days, 116 (91.3%) for 1 year +/- 24 days, and 122 (95.3%) aneurysms followed for >1 year. Transient and permanent morbidity occurred in 3.2% and 0.8% of procedures, respectively. The overall mortality rate was 1.5%. CONCLUSIONS: This retrospective study in real-world patients demonstrated the safety and efficacy of the FRED for the treatment of intracranial aneurysms. In most cases, treatment with a single FRED resulted in complete angiographic occlusion at 1 year.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 20 条
[1]   Predictors of Incomplete Occlusion following Pipeline Embolization of Intracranial Aneurysms: Is It Less Effective in Older Patients? [J].
Adeeb, N. ;
Moore, J. M. ;
Wirtz, M. ;
Griessenauer, C. J. ;
Foreman, P. M. ;
Shallwani, H. ;
Gupta, R. ;
Dmytriw, A. A. ;
Motiei-Langroudi, R. ;
Alturki, A. ;
Harrigan, M. R. ;
Siddiqui, A. H. ;
Levy, E. I. ;
Thomas, A. J. ;
Ogilvy, C. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) :2295-2300
[2]  
[Anonymous], PIV STUD FRED STENT
[3]   Pipeline for uncoilable or failed aneurysms: 3-year follow-up results [J].
Becske, Tibor ;
Potts, Matthew B. ;
Shapiro, Maksim ;
Kallmes, David F. ;
Brinjikji, Waleed ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvan ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
JOURNAL OF NEUROSURGERY, 2017, 127 (01) :81-88
[4]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[5]   Management of Unruptured Saccular Aneurysms of the M1 Segment with Flow Diversion [J].
Bhogal, Pervinder ;
Martinez, Rosa ;
Gansladt, Oliver ;
Baezner, Haensjorg ;
Henkes, Hans ;
Aguilar, Marta .
CLINICAL NEURORADIOLOGY, 2018, 28 (02) :209-216
[6]   Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Cirillo, Luigi ;
de Divitiis, Oreste ;
Solari, Domenico ;
Cappabianca, Paolo .
NEUROSURGICAL FOCUS, 2017, 42 (06)
[7]   Difficult Aneurysms for Endovascular Treatment: Overwide or Undertall? [J].
Brinjikji, W. ;
Cloft, H. J. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) :1513-1517
[8]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[9]   Matched Comparison of Flow Diversion and Coiling in Small, Noncomplex Intracranial Aneurysms [J].
Chalouhi, Nohra ;
Daou, Badih ;
Barros, Guilherme ;
Starke, Robert M. ;
Chitale, Ameet ;
Ghobrial, George ;
Dalyai, Richard ;
Hasan, David ;
Gonzalez, L. Fernando ;
Tjoumakaris, Stavropoula ;
Rosenwasser, Robert H. ;
Jabbour, Pascal .
NEUROSURGERY, 2017, 81 (01) :92-96
[10]   Treatment of complex anterior cerebral artery aneurysms with Pipeline flow diversion: mid-term results [J].
Dabus, Guilherme ;
Grossberg, Jonathan A. ;
Cawley, C. Michael ;
Dion, Jacques E. ;
Puri, Ajit S. ;
Wakhloo, Ajay K. ;
Gonsales, Douglas ;
Aguilar-Salinas, Pedro ;
Sauvageau, Eric ;
Linfante, Italo ;
Hanel, Ricardo A. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (02) :147-U35