The Effect of Rod Diameter on Correction of Adolescent Idiopathic Scoliosis at Two Years Follow-Up

被引:17
作者
Prince, Daniel E. [1 ]
Matsumoto, Hiroko [2 ]
Chan, Charles M. [3 ]
Gomez, Jaime A. [3 ]
Hyman, Joshua E. [2 ,4 ]
Roye, David P., Jr. [2 ,4 ]
Vitale, Michael G. [2 ,4 ]
机构
[1] Sinai Hosp Baltimore, Baltimore, MD USA
[2] Columbia Univ, Div Pediat Orthopaed Surg, Dept Orthopaed Surg, New York, NY 10032 USA
[3] Columbia Univ, Dept Orthopaed Surg, New York, NY 10032 USA
[4] Columbia Univ, Med Ctr, New York Presbyterian Morgan Stanley Childrens Ho, New York, NY 10032 USA
关键词
adolescent idiopathic scoliosis (AIS); posterior spinal instrumentation and fusion; correction of spinal deformity; rod diameter; POSTERIOR SPINAL-FUSION; PEDICLE SCREW; ANTERIOR INSTRUMENTATION; CONSTRUCT STIFFNESS; MECHANICAL STRENGTH; VARIABILITY;
D O I
10.1097/BPO.0b013e318288b3c1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: The review of multicenter national pediatric scoliosis database. Objective: The purpose of this study was to compare the radiographic outcomes of patients who underwent scoliosis surgery utilizing different rod diameter constructs by the posterior approach. Background: Little attention has specifically been focused on the effect of rod diameter on correction of spinal deformity after posterior spinal instrumentation and fusion in children with adolescent idiopathic scoliosis (AIS). Methods: The review of national database comprised of 1125 patients, of which 352 patients had a minimum follow-up of 2 years. Of these, 163 patients received 5.5 mm and 189 patients received 6.35 mm diameter rods for posterior spinal instrumentation. Results: The 6.35 mm rods were used more often for patients who were male, taller, heavier, with larger coronal curves, and more flexible curves. Larger diameter rods were also more likely to be stainless steel, implanted with an increased number of implants per level, and an increased number of pedicle screws used on the concavity of the curve. Univariate analysis of coronal curve showed a significant difference between 5.5 and 6.35 mm rods in correction (67.0% vs. 57.3%) at 2 years. Multivariate analysis revealed that the most significant factors affecting coronal curve correction at 2 years were rod diameter, the patient's preoperative coronal major curve and flexibility, and the implant density. In the sagittal plane, preoperative sagittal curve and rod diameter are the predictors of sagittal correction at 2 years. Conclusions: The study did not support our hypothesis that larger rods would be associated with a greater correction of frontal and sagittal plane in patients with AIS. In addition to rod diameter, implant density and the inherent flexibility and deformity of the patient were found to be influential factors contributing for the correction and maintenance of coronal and sagittal curves in AIS.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 16 条
[1]   Variability of spinal instrumentation configurations in adolescent idiopathic scoliosis [J].
Aubin, Carl-Eric ;
Labelle, Hubert ;
Ciolofan, Oana C. .
EUROPEAN SPINE JOURNAL, 2007, 16 (01) :57-64
[2]   The effects of hook pattern and kyphotic angulation on mechanical strength and apical rod strain in a long-segment posterior construct using a synthetic model [J].
Belmont, PJ ;
Polly, DW ;
Cunningham, BW ;
Klemme, WR .
SPINE, 2001, 26 (06) :627-635
[3]   SPINAL-FUSION AUGMENTED BY LUQUE-ROD SEGMENTAL INSTRUMENTATION FOR NEUROMUSCULAR SCOLIOSIS [J].
BROOM, MJ ;
BANTA, JV ;
RENSHAW, TS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01) :32-44
[4]  
Foley K.T., 2001, NEUROSURGERY FOCUS, V10, P1, DOI [10.3171/foc.2001.10.4.11, DOI 10.3171/foc.2001.10.4.11]
[5]   EFFECT OF SPINAL CONSTRUCT STIFFNESS ON EARLY FUSION MASS INCORPORATION - EXPERIMENTAL-STUDY [J].
JOHNSTON, CE ;
ASHMAN, RB ;
BAIRD, AM ;
ALLARD, RN .
SPINE, 1990, 15 (09) :908-912
[6]   Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis [J].
Kim, YJ ;
Lenke, LG ;
Kim, J ;
Bridwell, KH ;
Cho, SK ;
Cheh, G ;
Sides, B .
SPINE, 2006, 31 (03) :291-298
[7]   Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis [J].
Kim, YJ ;
Lenke, LG ;
Cho, SK ;
Bridwell, KH ;
Sides, B ;
Blanke, K .
SPINE, 2004, 29 (18) :2040-2048
[8]   Single-rod versus dual-rod anterior instrumentation for idiopathic scoliosis -: A biomechanical study [J].
Lowe, TG ;
Enguidanos, ST ;
Smith, DAB ;
Hashim, S ;
Eule, JM ;
O'Brien, MF ;
Diekmann, MJ ;
Wilson, L ;
Trommeter, JM .
SPINE, 2005, 30 (03) :311-317
[9]   Coronal and sagittal plane correction in adolescent idiopathic scoliosis - A comparison between all pedicle screw versus hybrid thoracic hook lumbar screw constructs [J].
Lowenstein, Jason E. ;
Matsumoto, Hiroko ;
Vitale, Michael G. ;
Weidenbaum, Mark ;
Gomez, Jaime A. ;
Lee, Francis Young-In ;
Hyman, Joshua E. ;
Roye, David P., Jr. .
SPINE, 2007, 32 (04) :448-452
[10]   Biomechanical properties of anterior thoracolumbar multisegmental fixation - An analysis of construct stiffness and screw-rod strain [J].
Oda, I ;
Cunningham, BW ;
Lee, GA ;
Abumi, K ;
Kaneda, K ;
McAfee, PC .
SPINE, 2000, 25 (18) :2303-2311